Stephan Allgeier

Dr. Stephan Allgeier

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2014 in Diabetes
Verified
Journal Article
Open access
PDF file
DZDan Ziegler
Dan Ziegler
NPNikolaos Papanas
Nikolaos Papanas
AZAndrey Zhivov
Andrey Zhivov
SAStephan Allgeier
Stephan Allgeier
KWKarsten Winter
Karsten Winter
FGfor the German Diabetes Study (GDS) Group
for the German Diabetes Study (GDS) Group
We sought to determine whether early nerve damage may be detected by corneal confocal microscopy (CCM), skin biopsy, and neurophysiological tests in 86 recently diagnosed type 2 diabetic patients compared with 48 control subjects. CCM analysis using novel algorithms to reconstruct nerve fiber images was performed for all fibers and major nerve fibers (MNF) only. Intraepidermal nerve fiber density (IENFD) was assessed in skin specimens. Neurophysiological measures included nerve conduction studies (NCS), quantitative sensory testing (QST), and cardiovascular autonomic function tests (AFTs). Compared with control subjects, diabetic patients exhibited significantly reduced corneal nerve fiber length (CNFL-MNF), fiber density (CNFD-MNF), branch density (CNBD-MNF), connecting points (CNCP), IENFD, NCS, QST, and AFTs. CNFD-MNF and IENFD were reduced below the 2.5th percentile in 21% and 14% of the diabetic patients, respectively. However, the vast majority of patients with abnormal CNFD showed concomitantly normal IENFD and vice versa. In conclusion, CCM and skin biopsy both detect nerve fiber loss in recently diagnosed type 2 diabetes, but largely in different patients, suggesting a patchy manifestation pattern of small fiber neuropathy. Concomitant NCS impairment points to an early parallel involvement of small and large fibers, but the precise temporal sequence should be clarified in prospective studies.

1 August 2011 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
SAStephan Allgeier
Stephan Allgeier
AZAndrey Zhivov
Andrey Zhivov
FEFranz Eberle
Franz Eberle
BKBernd Koehler
Bernd Koehler
SMSusanne Maier
Susanne Maier
OSOliver Stachs
Oliver Stachs
Purpose.: To overcome the anterior corneal mosaic (ACM) phenomenon in in vivo confocal laser scanning microscopy (CLSM) and to reconstruct undistorted images of the subbasal nerve plexus (SNP), facilitating morphometric analysis in the presence of ACM ridges. Methods.: CLSM was performed in five healthy volunteers. An original image processing algorithm based on phase correlation was used to analyze and reduce motion distortions in volume scan image sequences. Three-dimensional tracing of the SNP was performed to reconstruct images containing only the SNP layer, with nerve fibers clearly visible even in ACM areas. Results.: Real-time mapping of the SNP revealed the presence of ridges with K-structures underneath them in all cases. The occurrence of K-structures correlated directly with development of ACM observed by slit lamp and resulted in massive deformation at the level of Bowman's membrane, seriously interfering with examination of SNP structures. The average elevation of ACM ridges was 20.6 μm (range, 8.7–34.0 μm). The novel method presented permitted reconstruction of the SNP layer in regions of ACM. Conclusions.: The described method allows the precise analysis and elimination of motion artifacts in CLSM volume scans, in conjunction with the capability to reconstruct SNP structures even in the presence of severe ACM. The robustness and automation of the described algorithms require ongoing development, but this will provide a sound basis for extended studies of corneal nerve regeneration or degeneration and for use in clinical practice.

8 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AGAline Götze
Aline Götze
SKSophie von Keyserlingk
Sophie von Keyserlingk
SPSabine Peschel
Sabine Peschel
UJUlrike Jacoby
Ulrike Jacoby
CSCorinna Schreiver
Corinna Schreiver
DFDagmar-Christiane Fischer
Dagmar-Christiane Fischer
Optical coherence tomography (OCT) of the retina and corneal confocal laser scanning microscopy (CLSM) of the subbasal nerve plexus (SBP) are noninvasive techniques for quantification of the ocular neurodegenerative changes in individuals with type 1 diabetes mellitus (T1DM). In adult T1DM patients these changes are hardly related to T1DM only. Instead, ageing and/or lifestyle associated comorbidities have to be considered as putative confounding variables. Therefore, we investigated pediatric T1DM patients (n = 28; 14.2 ± 2.51 y; duration of disease: 5.39 ± 4.16 y) without clinical signs of diabetic retina disease, neuropathy, vasculopathy or nephropathy and compared our findings with those obtained in healthy controls (n = 46; 14.8 ± 1.89 y). The SBP was characterized by the averaged length, thickness, and tortuosity of nerve fibers as well as the number of branching and connecting points. OCT was used to determine the total thickness of the retina (ALL) and the thickness of each retinal layer. Both methods revealed signs of early neurodegenerative changes, e.g. thinning of distinct retinal layers at the pericentral ring and shortening of corneal nerve fibers that are already present in pediatric T1DM patients. Standardization of instruments and algorithms are urgently required to enable uniform comparison between different groups and define normative values to introduce in the clinical setting.

1 September 2014 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
SAStephan Allgeier
Stephan Allgeier
SMSusanne Maier
Susanne Maier
RMRalf Mikut
Ralf Mikut
SPSabine Peschel
Sabine Peschel
KRKlaus-Martin Reichert
Klaus-Martin Reichert
BKBernd Köhler
Bernd Köhler
Purpose.: A growing number of studies provide evidence that the morphology of the corneal subbasal nerve plexus (SNP), examined by corneal confocal microscopy (CCM), is a sensitive marker for diabetic peripheral neuropathy. However, it has been established that the field of view of a single CCM image (≈0.16 mm2) is insufficient for reliable assessment of corneal nerve fiber morphology. The present work proposes a highly automated technique for imaging an extended area of the SNP and creating large-scale montages. Methods.: A moving fixation target is presented on a small display in front of the nonexamined eye. By guiding the viewing direction of the subject in an expanding spiral pattern, the scanned corneal area is continuously expanded. Specialized software algorithms subsequently assemble a mosaic image from the acquired CCM image data. The proposed technique was applied in 12 healthy subjects. Results.: Montage images of the SNP were successfully created from all examinations performed. The mean imaged SNP area was 9.86 mm2 (range, 1.62–18.31 mm2). The mean CCM duration was 65.33 seconds (range, 14.58–142.58 seconds). Conclusions.: The key advances embodied in the proposed technique are its high degree of integration and automation (both for image acquisition and image processing) and the resulting short duration of CCM. By providing an easy-to-use tool for obtaining large-scale mosaic images of the SNP, this technique has the potential to facilitate larger clinical trials where SNP morphology is used as a surrogate marker for peripheral neuropathy.

1 May 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SBSebastian Bohn
Sebastian Bohn
KSKarsten Sperlich
Karsten Sperlich
SAStephan Allgeier
Stephan Allgeier
ABAndreas Bartschat
Andreas Bartschat
RPRuby Prakasam
Ruby Prakasam
OSOliver Stachs
Oliver Stachs
We present an in vivo confocal laser scanning microscopy based method for large 3D reconstruction of the cornea on a cellular level with cropped volume sizes up to 266 x 286 x 396 µm3. The microscope objective used is equipped with a piezo actuator for automated, fast and precise closed-loop focal plane control. Furthermore, we present a novel concave surface contact cap, which significantly reduces eye movements by up to 87%, hence increasing the overlapping image area of the whole stack. This increases the cuboid volume of the generated 3D reconstruction significantly. The possibility to generate oblique sections using isotropic volume stacks opens the window to slit lamp microscopy on a cellular level.

24 March 2015 in Current Eye Research
Verified
Journal Article
Closed access
KWKarsten Winter
Karsten Winter
PSPatrick Scheibe
Patrick Scheibe
BKBernd Köhler
Bernd Köhler
SAStephan Allgeier
Stephan Allgeier
RGRudolf F. Guthoff
Rudolf F. Guthoff
OSOliver Stachs
Oliver Stachs
The corneal subbasal nerve plexus (SNP) offers high potential for early diagnosis of diabetic peripheral neuropathy. Changes in subbasal nerve fibers can be assessed in vivo by confocal laser scanning microscopy (CLSM) and quantified using specific parameters. While current study results agree regarding parameter tendency, there are considerable differences in terms of absolute values. The present study set out to identify factors that might account for this high parameter variability. In three healthy subjects, we used a novel method of software-based large-scale reconstruction that provided SNP images of the central cornea, decomposed the image areas into all possible image sections corresponding to the size of a single conventional CLSM image (0.16 mm2), and calculated a set of parameters for each image section. In order to carry out a large number of virtual examinations within the reconstructed image areas, an extensive simulation procedure (10,000 runs per image) was implemented. The three analyzed images ranged in size from 3.75 mm2 to 4.27 mm2. The spatial configuration of the subbasal nerve fiber networks varied greatly across the cornea and thus caused heavily location-dependent results as well as wide value ranges for the parameters assessed. Distributions of SNP parameter values varied greatly between the three images and showed significant differences between all images for every parameter calculated (p < 0.001 in each case). The relatively small size of the conventionally evaluated SNP area is a contributory factor in high SNP parameter variability. Averaging of parameter values based on multiple CLSM frames does not necessarily result in good approximations of the respective reference values of the whole image area. This illustrates the potential for examiner bias when selecting SNP images in the central corneal area.