The study investigated the level of thermal comfort in historical buildings located at a relatively high altitude in the Arabian Desert of Saudi Arabia. The study focused on the impact of the use of thermal mass and orientation on the level of thermal performance at Shubra and Boqri Palaces. Qualitative and quantitative analyses were used in this study, including a questionnaire interview with architecture experts living at the relatively high altitude of Taif city, to obtain data and information from local experts. The computer software TAS EDSL was used along with on-site equipment, such as thermal imaging cameras and data loggers, to observe the physical conditions of the building in terms of its thermal performance. The study revealed that the experts’ age and years of experience were important aspects while collecting data from them during the survey. The use of thermal mass had a slight impact on the indoor air temperature as well as the energy consumption, but it helped in providing thermal comfort. Use of ventilation can improve thermal comfort level. Evaporative cooling technique has a considerable impact on reducing indoor air temperature with 4 °C drop, improving the thermal comfort sensation level. The novelty of this work is that, it links the outcomes of qualitative results of experts with field monitoring as well as computer modelling. This can contribute as method to accurately collect data in similar case studies.
A split louver consists of two sections with their slat angles to be adjusted separately for glare protection and redirection of sunlight, respectively. The upper section works in conjunction with the lower section to enhance daylight availability and uniformity throughout the year. The study aims to improve the daylighting performance of the split louver by applying a simplified parametric control, which predetermines the angle difference between adjacent slats in the upper section for a chosen solar altitude and then keeps this difference fixed during operation. The slats in the upper section can be changed parametrically using the Grasshopper to reflect daylight onto the ceiling and then illuminate the rear zone of a space. The lower section of the split louver can control the daylight in the front space area and may affect the amount of light in the back. The performance indicator in evaluating the proposed split louver design for the chosen typical days is the percentage coverage of the work plane area for the illuminance range of 150~750 lux, which was achieved up to 100% in some cases. The proposed split louver with the simplified parametric control has the potential to provide relatively consistent and distributed daylight coverage of the floor area and a glare-free environment.
Achieving and maintaining indoor thermal comfort is a crucial factor for energy saving and human health, especially in heavily occupied public buildings, such as mosque buildings. The acceptable level of thermal comfort should not be achieved at the expense of damaging the environment by using preventable energy depletion. This study aims to investigate what level thermal comfort is achieved and related issues in mosque buildings in Abha city, which has a semi-arid moderate/cold mountainous climate. The research involved a computer modelling investigation by using Thermal Analysis Software (TAS). A number of comparisons of the simulation results with actual measurement data in mosque buildings, such as temperature, relative humidity, and energy demand were conducted. Main factors influencing thermal comfort and PMV were investigated for the selected mosques. In addition, thermal performance of mosques’ fabrics and envelopes in terms of solar gain and heat loss/gain by conduction and its impacts on thermal comfort and energy demands were also discussed. The outcome showed some discomfort due to heat gain in summer and heat loss in winter. The results also revealed that the main factors behind heat gain or loss were the poor quality of the investigated mosque buildings’ envelopes, including walls, roofs, floors, windows, and doors.
Building energy efficiency is vital to achieve human thermal comfort with minimum energy consumption. It is a great concern in extremely hot countries such as Oman. This study aims to investigate the thermal performance of contemporary mosque buildings in comparison to traditional mosque buildings in Oman. The research methodology employs energy modelling using EDSL’s Tas Engineering computer simulation software. The analysis focused on how traditional mosque buildings compare to contemporary mosque buildings in terms of dry bulb air temperature and different thermal loads. The outcome showed the traditional mosque building design and construction are better suited for free-running buildings, while contemporary mosque building design and construction achieved less cooling load demand per area.
The required cooling energy in buildings exceeds 65% of the total energy consumed inside buildings under the extreme climatic conditions of Saudi Arabia. The proper design of buildings’ envelopes has a considerable potential in reducing such levels, especially in public buildings. The reported study evaluated the thermal performance of mosque buildings with focus on the solar gains through the envelope elements. Computer simulations were carried out using Thermal Analysis Software (TAS). In addition, the thermal and comfort votes of the worshippers in one mosque were collected. The findings revealed uncomfortable thermal conditions, especially during summer months. The required cooling energy ranged between 37% and 55% in the investigated mosques. Investigating the solar gains of the envelope elements of one mosque indicated that the roof is the largest contributor to solar gain, which highlights the potential for future research to explore new constructional alternatives with the aim of improving the roofs’ thermal performance.
Envi-met is the most-used simulation tool to assess outdoor thermal comfort in urban microclimates. Considering reported disparities between modeled and observed mean radiant temperature (MRT), failing to accurately predict the MRT may have a negative impact on the conclusions drawn by urban designers and policy makers. Therefore, this study aims to validate the Envi-met model’s efficiency for predicting MRT in the hot arid climate of Mecca city. Sensitivity analyses were conducted to investigate the settings and inputs of Envi-met, including two- and six-directional methods for calculating MRT, shortwave radiation projection factors, Indexed View Sphere (IVS), Advanced Canopy Radiation Transfer (ACRT), and the localization of materials and vegetation. Two statistical metrics (RMSE and MAE) were employed to assess Envi-met’s performance for the two evaluation points. Envi-met produced the best results with the 6-directional, ƒp-RayM (in winter) and ƒp-City (in summer), IVS on and ACRT on mode, and localized soil condition, materials, and vegetation inputs. An analysis of the modeled MRT results illustrated that error magnitudes were decreased significantly as a result of sufficient settings and inputs; for example, RMSE was improved by 2.31 and 8.48 K in the winter and summer open site results, respectively, and by 7.30 K in the summer under-tree site. Overall, the results of winter and summer analyses demonstrate average RMSE of 4.99 K and MAE of 4.02 K. The findings illustrate that substantial enhancement of model performance can be achieved through the use of proper settings and inputs.