Orthodontic implants have found widespread use as means of maximum skeletal anchorage in fixed orthodontic treatment, their optimal insertion location in the hard palate, however, is still controversial. The aim of this study was therefore to assess mean bone height across the hard palate and possible age- and sex related differences to identify the most favourable location according to maximum bone height, optimizing primary stability and survival of inserted orthodontic implants. In this retrospective cross-sectional study, maxillary pretreatment CBCT scans of 180 healthy orthodontic patients (95♀, 85♂, age 8–40 years) were analysed with regard to vertical palatal bone height in the midpalatal area at 88 validated points distanced 2 mm from each other forming a grid of 0–14 mm posterior to the incisive foramen and 10 mm lateral of the midpalatal suture. Differences in bone height regarding sex and topographical location were assessed by three-way ANOVA. In general, the midpalatal suture as well as the anterior-lateral palatal region showed distinctly higher mean palatal bone height with its maximum 4 mm posterior of the incisive foramen, whereas bone height was limited at the posterior region of the midpalatal suture. Women generally had significantly decreased palatal bone height compared to men at all measurement points. Higher age was associated with a decrease of bone height in the anterior and posterior lateral palatal region and the median palatal raphe with significant age differences. The midpalatal suture as well as the anterior lateral palate seem to be most suitable for the insertion of orthodontic implants. Palatal bone height, however, was found to be sex- and age-specific, thus sex- and age-related differences should be taken into account, particularly regarding implant length. The ideal insertion site in the palate with sufficient bone height for orthodontic implants is 0-8 mm (men) or 0-6 mm (women) posterior to the incisive foramen and 10 mm lateral to the midpalatal suture. This study has been registered and approved by the Ethics Committee of the University of Witten/Herdecke, Germany (12/2016).
1 September 2018 in Computers in Biology and Medicine
Introduction: Development of white spot lesions (WSLs) during orthodontic treatment is a common risk factor. Fixation of the orthodontic appliances with glass ionomer cements could reduce the prevalence of WSL’s due to their fluoride release capacities. The purpose of this study was to evaluate differences of fluoride release properties from resin-modified and conventional glass ionomer cements (GICs). Methods: The resin-modified GICs Fuji ORTHO LC (GC Orthodontics), Meron Plus QM (VOCO), as well as the conventional GICs Fuji ORTHO (GC Orthodontics), Meron (VOCO) and Ketac Cem Easymix (3M ESPE) were tested in this study. The different types of GICs were applied to hydroxyapatite discs according to the manufacturer’s instructions and stored in a solution of TISAB III (Total Ionic Strength Adjustment Buffer III) and fluoride-free water at 37°C. Fluoride measurements were made after 5 minutes, 2 hours, 24 hours, 14 days, 28 days, 2 months, 3 months and 6 months. One factor analysis of variance (ANOVA) was used for the overall comparison of the cumulative fluoride release (from measurement times of 5 minutes to 6 months) between the different materials with the overall level of significance set to 0.05. Tukey’s post hoc test was used for post hoc pairwise comparisons in the cumulative fluoride release between the different materials. Results: The cumulative fluoride release (mean ± sd) in descending order was: Fuji ORTHO LC (221.7 ± 10.29 ppm), Fuji ORTHO (191.5 ± 15.03 ppm), Meron Plus QM (173.0 ± 5.89 ppm), Meron (161.3 ± 7.84 ppm) and Ketac Cem Easymix (154.6 ± 6.09 ppm) within 6 months. Analysis of variance detected a significant difference in the cumulative fluoride release between at least two of the materials (rounded p-value < 0.001). Pairwise analysis with Tukey’s post hoc test showed a significant difference in the cumulative fluoride release for all the comparisons except M and MPQM (p = 0.061) and KCE and M (p = 0.517). Conclusion: Fluoride ions were released cumulatively over the entire test period for all products. When comparing the two products from the same company (Fuji ORTHO LC vs. Fuji ORTHO from GC Orthodontics Europe GmbH and Meron Plus QM vs. Meron from VOCO GmbH, Mannheim, Germany), it can be said that the resin-modified GICs have a higher release than conventional GICs. The highest individual fluoride release of all GICs was at 24 hours. A general statement, whether resin-modified or conventional GICs have a higher release of fluoride cannot be made.
Objective: The aim of the present study was to investigate the influence of three grafting materials for cleft repair on orthodontic tooth movement in rats. Materials and methods: Artificial alveolar clefts were created in 21 Wistar rats and were repaired 4 weeks later using autografts, human xenografts and synthetic bone substitute (beta-tricalcium phosphate/hydroxyapatite [β-TCP/HA]). A further 4 weeks later, the first molar was moved into the reconstructed maxilla. Microfocus computed tomography (μCT) was performed six times (T0–T5) to assess the tooth movement and root resorption. After 8 weeks, the affected reconstructed jaw was resected for histopathological investigation. Results: Total distances reached ranged from 0.82 ± 0.72 mm (β-TCP/HA) to 0.67 ± 0.27 mm (autograft). The resorption was particularly determined at the mesiobuccal root. Descriptive tooth movement slowed and root resorption increased slightly. However, neither the radiological changes during tooth movement (µCT T1 vs. µCT T5: autograft 1.85 ± 0.39 mm3 vs. 2.38 ± 0.35 mm3, p = 0.30; human xenograft 1.75 ± 0.45 mm3 vs. 2.17 ± 0.26 mm3, p = 0.54; β-TCP/HA: 1.52 ± 0.42 mm3 vs. 1.88 ± 0.41 mm3, p = 0.60) nor the histological differences after tooth movement (human xenograft: 0.078 ± 0.05 mm2; β-TCP/HA: 0.067 ± 0.049 mm2; autograft: 0.048 ± 0.015 mm2) were statistically significant. Conclusion: The autografts, human xenografts or synthetic bone substitute used for cleft repair seem to have a similar effect on the subsequent orthodontic tooth movement and the associated root resorptions. Clinical relevance: Development of root resorptions seems to have a secondary role in choosing a suitable grafting material for cleft repair.
Background: Assessment of midpalatal suture maturation on cone-beam computed tomography (CBCT) scans is performed by visual inspection and is therefore subjective. The extent to which the assessment of midpalatal suture maturation is affected by rater experience has not been adequately explored in the existing literature, thus limiting the availability of evidence-based findings. This study compared the outcomes of classification by dental students, orthodontic residents, and orthodontists. Methods: Three different groups of students, orthodontic residents, and orthodontists evaluated 10 randomly chosen CBCT scans regarding midpalatal suture maturation from a pool of 179 patients (98 female and 81 male patients) aged 8 – 40 years which were previously classified by evaluating CBCT scans. The pool was set as benchmark utilizing midpalatal suture maturation classification by one examiner (OsiriX Lite version 11.0; Pixmeo SARL, Bernex, Switzerland). For assessment of intra-rater reliability of the examiners of each group the randomly chosen subjects were reclassified for midpalatal suture maturation after a wash-out period of two weeks by using the same software. Statistical analysis was performed to evaluate intra- and interrater reliability of the three groups with differing experience level. Results: Groupwise intra-rater reliability assessment between the classification and reclassification was weak for examiners with a low level of experience (k = 0.59). Orthodontists had highest degree of agreement with regard to benchmark classification with an inter-rater reliability to be considered as moderate (k = 0.68). Conclusions: Assessment of midpalatal suture maturation on CBCT scans appears to be a subjective process and is considerably related to the experience level of the examiner. A high level of clinical experience seems to be favorable but does not necessarily ensure accurate results.
1 July 2021 in Annals of Anatomy - Anatomischer Anzeiger