Forensic genetic genealogy (FGG) has primarily relied upon dense single nucleotide polymorphism (SNP) profiles from forensic samples or unidentified human remains queried against online genealogy database(s) of known profiles generated with SNP microarrays or from whole genome sequencing (WGS). In these queries, SNPs are compared to database samples by locating contiguous stretches of shared SNP alleles that allow for detection of genomic segments that are identical by descent (IBD) among biological relatives (kinship). This segment-based approach, while robust for detecting distant relationships, generally requires DNA quantity and/or quality that are sometimes not available in forensic casework samples. By focusing on SNPs with maximal discriminatory power and using an algorithm designed for a sparser SNP set than those from microarray typing, performance similar to segment matching was reached even in difficult casework samples. This algorithm locates shared segments using kinship coefficients in "windows" across the genome. The windowed kinship algorithm is a modification of the PC-AiR and PC-Relate tools for genetic relatedness inference, referred to here as the "whole genome kinship" approach, that control for the presence of unknown or unspecified population substructure. Simulated and empirical data in this study, using DNA profiles comprised of 10,230 SNPs (10K multiplex) targeted by the ForenSeq™ Kintelligence Kit demonstrate that the windowed kinship approach performs comparably to segment matching for identifying first, second and third degree relationships, reasonably well for fourth degree relationships, and with fewer false kinship associations. Selection criteria for the 10K SNP PCR-based multiplex and functionality of the windowed kinship algorithm are described.
Forensic mitochondrial DNA (mtDNA) analysis conducted using next-generation sequencing (NGS), also known as massively parallel sequencing (MPS), as compared to Sanger-type sequencing brings modern advantages, such as deep coverage per base (herein referred to as read depth per base pair (bp)), simultaneous sequencing of multiple samples (libraries) and increased operational efficiencies. This report describes the design and developmental validation, according to forensic quality assurance standards, of end-to-end workflows for two multiplexes, comprised of ForenSeq mtDNA control region and mtDNA whole-genome kits the MiSeq FGxTM instrument and ForenSeq universal analysis software (UAS) 2.0/2.1. Polymerase chain reaction (PCR) enrichment and a tiled amplicon approach target small, overlapping amplicons (60–150 bp and 60–209 bp for the control region and mtGenome, respectively). The system provides convenient access to data files that can be used outside of the UAS if desired. Studies assessed a range of environmental and situational variables, including but not limited to buccal samples, rootless hairs, dental and skeletal remains, concordance of control region typing between the two multiplexes and as compared to orthogonal data, assorted sensitivity studies, two-person DNA mixtures and PCR-based performance testing. Limitations of the system and implementation considerations are discussed. Data indicated that the two mtDNA multiplexes, MiSeq FGx and ForenSeq software, meet or exceed forensic DNA quality assurance (QA) guidelines with robust, reproducible performance on samples of various quantities and qualities.
14 August 2019 in International journal of legal medicine
Human dental remains encountered in criminal casework evidence, missing person cases, or mass disaster tragedies provide a valuable sample source for DNA typing when suitable soft tissue is unavailable. Using traditional methods, teeth samples can be challenging to process, resulting in low-quantity and/or quality nuclear DNA and insufficient profiles for comparisons. This study examines the performance of a three-part nuclear DNA analysis workflow for teeth samples based on (1) improved dental tissue recovery using the Dental Forensic Kit (DFKMR) (Universidad de los Andes) and DNA extraction with QuickExtract™ FFPE DNA Extraction Kit (Lucigen®), (2) quantification with InnoQuant® HY (InnoGenomics Technologies) for sensitive assessment of total human and male DNA quantity/quality, and (3) massively parallel sequencing for simultaneous genotyping of 231 short tandem repeat (STR) and single-nucleotide polymorphism (SNP) markers with the ForenSeq® DNA Signature Prep Kit (Verogen, Inc.). Initial evaluation of artificially degraded blood samples (n = 10) achieved highly sensitive and informative quantification results with InnoQuant® HY, enabling successful first pass genotyping with the MiSeq FGx® System. Twenty-three STR alleles (out of 85) and 70 identity informative SNP loci (out of 94) were recovered from two pg total long target DNA input (0.86 ng total short target input) and an InnoQuant degradation index (DI) of 460 (severely degraded). The three-part workflow was subsequently applied to teeth samples (dental pulp, root cement tissues; n = 13) with postmortem intervals (PMI) of the teeth ranging from 8 days to approximately 6 months. Informative SNP and STR DNA profiles were obtained, to include 78 STR alleles and 85 identity informative SNP loci typed (of 94 total SNP targets) in a 1 month, four-day PMI root cement sample with one pg total long target DNA input and a DI of 76. These data indicate successful performance of the proposed workflow from degraded DNA from teeth samples.