With the increased penetration of wind power, the influence of wind turbine generators on the grid power quality stipulates careful investigation and analysis. Direct driven permanent magnet synchronous generator (PMSG) with a back-to-back converter set is one of the promising technologies in wind power generation schemes. In this paper, comprehensive models of wind turbine are used to analyze power and voltage fluctuations. The short time flicker index is used to assess the voltage fluctuation emitted. The control scheme of the grid-side converter is supported with a voltage regulation loop to reduce flicker emission. The effects of grid and site parameters on voltage fluctuation are investigated. Simulation results show that reduced flicker emissions are given when the developed voltage regulation loop is activated. Reasonable values of grid and site parameters contribute in the minimization of voltage fluctuation and flicker emission levels
To ensure the full benefits from wind generation systems, an effective maximum power point tracking (MPPT) technique should be implemented. In this article, an adaptive fuzzy logic controller (AFLC) is presented as a control methodology for producing the peak power from a permanent magnet synchronous generator (PMSG)-based wind turbine (WT). Regardless of the importance and significance of modeling and simulation processes, experimental studies occupy the most important aspect and remain a big challenge. The first part of this article is devoted to the simulation and modeling of PMSG along with the control system by MATLAB/Simulink® package to develop the control system. To justify the simulation results, experimental validation tests are presented under the same status of wind speed profile and run period. The experimental validation is conducted using the DSPACE DS1104 control board and is compared with simulation results. Moreover, for a realistic response, actual wind speed data is utilized in this research depending on measured data from Ras Ghareb wind farm in the Gulf of Suez, Egypt. The obtained results confirm the superiority of AFLC compared with fuzzy logic controller and conventional PI control schemes. In addition, good tracking with high accuracy is obtained regarding experimental and simulations results. Moreover, an evaluation indices are employed for WT performance based on gross system efficiency and integral of the absolute error (IAE). These indices are used to demonstrate the feasibility of the AFLC methodology compared with traditional approaches under the same wind turbine status.
With the growing of electrical energy demand, wind energy gains higher potential and plays a vital role in energy sectors. Direct driven permanent magnet synchronous generator (PMSG) with a full size back-to-back converter set is one of the promising technologies employed with wind power generation. This paper focuses on developing a control scheme of PMSG-based wind turbines to obtain maximum wind power extraction and meet network code requirements. Comprehensive models of wind speed, wind turbine, PMSG and power electronic converters along with their control schemes are implemented in MATLAB/SIMULINK environment. Simulation results show the feasibility and robustness of the proposed control schemes for PMSG based wind turbines.
Due to the continuous increase of fuel prices and pollutions, the use of renewable energy especially wind has increased. In developing countries including Egypt, squirrel cage induction generator wind turbine (SCIG-WT) represents a considerable proportion of the total capacity of installed wind farm due to its qualities such as low cost and easy availability. However, its operation has a substantial effect on system stability. In contrast, doubly fed induction generator wind turbine (DFIG-WT) is broadly penetrated the electrical grid as it keeps the system stable. In this work, the ability of WT generators to continue operating rather than tripping at the time of faults is analyzed for proper stability investigation. The detailed control and stability of a grid-connected large scale SCIG and DFIG of Zafarana, Suez Gulf area, Egypt are discussed whereas the parameters of fault ride through (FRT) curve of Egypt grid code is utilized. Moreover, a precise analytical stability argument using a proposed integrated nonlinear dynamical model is presented. Conditions for global asymptotic stability of the SCIG in the sense of Lyapunov function (LF) are given and tested by time domain simulation. The eigenvalues of the matrices of LF and its derivative are determined by which the stability boundaries are determined depending on the positivity of these matrices. The dynamic behavior of the whole system is simulated in MATLAB/ Simulink interface programming while the practical data are collected from an experimental model consisting of DFIG-WT to demonstrate the efficacy of the FRT control system.
Microgrid (MG) technologies assist the power grid in evolving to become more efficient, less polluting, and more resilient by addressing the requirements of energy users. However, several technological issues arise as a result of the unpredictability and difficulty in estimating the efficacy and regulation of the many renewable energy resources (RERs) incorporated in MGs. Two of the most significant of these issues are maintaining system stability and power quality, which necessitate to get better the performance of the MGs. The most difficult challenge, system stability, can be achieved with successful Power Management System (PMS). This paper proposes an effective PMS for an AC MG equipped with a diesel generator (DG), a permanent magnet wind generator (PMWG), and a solar photovoltaic (PV) panel Based on an adaptable Artificial Neural Network (ANN). The ANN weights are properly tuned via the Enhanced Bald Eagle Search (EBES) optimization algorithm to produce a stable system during the whole training period, achieve MG energy balance, reduce the usage of fossil fuel DG and maintain MG voltage stability. In addition, for keeping power quality, an adaptive series shunt compensator (ASSC) is described in this work, along with a developed integrative PID controller, where the latter’s controller gains are ideally set utilizing the EBES optimization algorithm to perform adaptably with self-tuning when the operational circumstances of an MG change. various cases are displayed to test the strong of offered ASSC on harmonic mitigation, dynamic voltage stabilization, reactive power control and power factor correction. Moreover, comprehensive case study based on realistic on-site location for Zafarana region, Suez Gulf region of Egypt is proposed. Taking into account The changing nature of weather-related renewable energy, actual loads states and transient faults.
13 February 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
The current work proposes a new VT maintenance approach for restoring the oil’s insulation properties depending on the nanoparticles’ advantages. For the first time, a real-aged VT was used for the experimentation. Different experimental tests were performed and assessed on VT to ensure the effectiveness of the proposed technique, such as breakdown voltage (BDV), dissipation factor (DF), and insulation resistance (IR) tests. The experimental tests of VT were carried out before and after the treatment and compared with the new oil to prove the feasibility and robustness of the proposed technique. The experimental tests of VT were examined according to IEC standards. Based on the results, a significant improvement in the oil’s BDV and the insulation performance of the VT was conducted, indicating the substantial impact of nanoparticles for enhancing the maintenance of aged VT. The results indicated a significant improvement in the BDV of the oil and the insulation performance of the VT. Furthermore, a statistical analysis tool is used to assess and evaluate the accuracy of the experimental test. In addition, the K Nearest Neighbors (KNN) classifier was conducted to diagnose and predict the state of the VT, the fine KNN developed 100 % classification accuracy compared to 96.7 % accuracy for the coarse KNN classifier. The recorded experimental measurements and the numerical results emphasize that the proposed method provides superior features.