Kyung-Soon Park

Kyung-Soon Park

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 February 2016 in Sustainability
Verified
Journal Article
Open access
PDF file
HRHan-Soo Ryu
Han-Soo Ryu
KPKyung-Soon Park
Kyung-Soon Park
In the domestic and international environmentally friendly certification system, energy-related credit occupies a high ratio in the total distribution of certification score Leadership in the Energy and Environmental Design (LEED) system is a certification system developed by the US Green Building Council (USGBC) in order to assess the environmental friendliness of buildings. The energy-related credit is approximately 30% of the total and also the energy simulation ratio specifically is the highest among the single credits as it is 20%. In this research, the energy simulation process using Building Information Modeling (BIM) based on the energy simulation case performed at the A-Tower, LEED certification was proposed. It places an emphasis on the verification process which was short in the previous research. The architectural geometry modeled through the BIM tool is converted to the gbXML, and in this process the geometry is verified through the interference check functions, the gbXML Viewer and the FZKViewer. The energy simulation is performed after the verification procedure. The geometry verification process in the A-Tower project is presented throughout this paper. In conclusion, an improved process is proposed for the productivity and reliability of energy simulation.

23 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
YJYongjoon Jun
Yongjoon Jun
Seungho AhnSeungho Ahn
Seungho Ahn
KPKyung-Soon Park
Kyung-Soon Park
The Green Remodeling Project under South Korea’s Green New Deal policy is a government-led project intended to strengthen the performance sector directly correlated with energy performance among various elements of improvement applicable to building remodeling by replacing insulation materials, introducing new and renewable energy, introducing high-efficiency equipment, etc., with public buildings taking the lead in green remodeling in order to induce energy efficiency enhancement in private buildings. However, there is an ongoing policy that involves the application of a fragmentary value judgment criterion, i.e., whether to apply technical elements confined to the enhancement of the energy performance of target buildings and the prediction of improvement effects according thereto, thus resulting in the phenomenon of another important value criterion for green remodeling, i.e., the enhancement of the occupant (user) comfort performance of target buildings as one of its purposes, being neglected instead. In order to accurately grasp the current status of these problems and to promote ‘expansion of the value judgment criteria for green remodeling’ as an alternative, this study collected energy usage data of buildings actually used by public institutions and then conducted a total analysis. After that, the characteristics of energy usage were analyzed for each of the groups of buildings classified by year of completion, thereby carrying out an analysis of the correlation between the non-architectural elements affecting the actual energy usage and the actual energy usage data. The correlation between the improvement performance of each technical element and the actual improvement effect was also analyzed, thereby ascertaining the relationship between the direction of major policy strategies and the actual energy usage. As a result of the relationship analysis, it was confirmed that the actual energy usage is more affected by the operating conditions of the relevant building than the application of individual strategic elements such as the performance of the envelope insulation and the performance of the high-efficiency system. In addition, it was also confirmed that the usage of public buildings does not increase in proportion to their aging. The primary goal of reducing energy usage in target buildings can be achieved if public sector (government)-led green remodeling is pushed ahead with in accordance with biased value judgment criteria, just as in the case of a campaign to refrain from operating cooling facilities in aging public buildings. However, it was possible to grasp through the progress of this study that the remodeling may also result in the deterioration of environmental comfort and stability, such as the numerical value of the indoor thermal environment. The results of this study have the significance of providing basic data for pushing ahead with a green remodeling policy in which the value judgment criteria for aging existing public buildings are more expanded, and it is necessary to continue research in such a direction that the quantitative purpose of green remodeling, which is to reduce energy usage in aging public buildings, and its qualitative purpose, which is to enhance their environmental performance for occupants’ comfort, can be mutually balanced and secured at the same time.

20 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
HKHyemi Kim
Hyemi Kim
KPKyung-Soon Park
Kyung-Soon Park
HKHwan-Yong Kim
Hwan-Yong Kim
YSYoung-hak SONG
Young-hak SONG
The additional process of load calculation during the retrofit of heating, ventilation, and air conditioning (HVAC) equipment has been generally omitted in Korea, in recent years. Instead, a simple replacement of HVAC equipment, based on existing HVAC capacities, has been used, which is limited when taking the variation of internal heat gain into consideration, due to changes in the consumption power due to light and office automation (OA) equipment in recent years. Thus, this study aimed to identify a change in internal heat gains over 30 years, from 1985 to 2015, study investigated actual measurement-based academic papers and catalogs about OA equipment, lighting, and the number of occupants per unit area. The heat load produced from OA equipment has increased by approximately 49.6% in 2015 compared to that of 1980, and the heat load from lighting equipment has decreased by 47% compared to that of fluorescent-based lighting, and the heat load from human bodies was approximately 10 W/m2 on average, which showed a minimal change over the past 30 years. The internal heat gain calculated for 30,000 m2 of total floor area has increased constantly for the last 30 years. Note that the internal heat gains were designed excessively, as the values used in literature was approximately 17% to 50% smaller than the value used normally in the case of pre-2000 designs, and the values used after 2000 were approximately 35% to 50% smaller than the design standard value.

1 December 2021 in Solar Energy
Verified
Journal Article
Open access
YJYongjoon Jun
Yongjoon Jun
KPKyung-Soon Park
Kyung-Soon Park
YSYoung-Hak Song
Young-Hak Song

27 August 2017 in Energies
Verified
Journal Article
Open access
PDF file
YJYongjoon Jun
Yongjoon Jun
YSYoung-hak SONG
Young-hak SONG
KPKyung-Soon Park
Kyung-Soon Park
Although water is an essential element for the survival of all humankind, there are, however, still areas where water is not sufficiently supplied. It is a reality today that supplying energy for producing clean water is also difficult in such areas. This study develops a fresh water generator using solar heat, which is a clean energy source, and a small-scale desalination system which can be configured in parallel so that it can cope with various changes in the water supply situation. In addition, this study has developed a simulation program capable of estimating the optimum installation angle of a solar collector in such a way as to be suitable for the period of water demand, as well as the environment of the installation area, by allowing for the fact that it is difficult to change the installation angle or conditions after the installation of a fixed solar collector. In order to carry out these issues, this study has set up the experimental apparatus of a small-scale desalination system and obtained data on the amounts of fresh water generation depending on solar heat storage temperatures through empirical experiments. By applying the data in the simulation program, this study proposed the optimum installation angle for the necessary conditions.

17 March 2016 in Energies
Verified
Journal Article
Open access
PDF file
KPKyung-Soon Park
Kyung-Soon Park
SKSangwoo Kim
Sangwoo Kim
SYSeonghwan Yoon
Seonghwan Yoon
The efficient operation of a passive solar house requires an efficient ventilation system to prevent the loss of energy and provide the required ventilation rates. This paper proposes the use of “breathing architectural members” (BAMs) as passive natural ventilation devices to achieve much improved ventilation and insulation performance compared to mechanical ventilation. Considering the importance of evaluating the ventilation and insulation performances of the members, we also propose numerical models for predicting the heat and air movements afforded by the members. The numerical model was validated by comparison with experimental results. The effectiveness of the BAMs was also verified by installation in houses located in an area with warm climate. For this purpose, chamber experiments were performed using samples of the BAMs, as well as numerical simulations to assess natural ventilation and heat load. The main findings of the study are as follows: (1) the one-dimensional chamber experiments confirmed the validity of the numerical models for predicting the heat and air movements afforded by the BAMs. Comparison of the experimental and calculated values for the temperature of air that flowed into the room from outside revealed a difference of less than 5%; (2) observations of the case studies in which BAMs were installed in the ceilings and exterior walls of Tokyo model houses revealed good annual ventilation and energy-saving effects. When BAMs with an opening area per unit area of A = 0.002 m2/m2 were applied to three surfaces, the required ventilation rate was 0.5 ACH (air changes per hour), and this was achieved consistently. Compared to a house with general insulation and conventional mechanical ventilation, heating load was reduced by 15.3%–40.2% depending on the BAM installation points and the differing areas of the house models.