ibtihaj eid abalawi

Ms. ibtihaj eid abalawi

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
IAibtihaj eid abalawi
ibtihaj eid abalawi
HAHanan Alatawi
Hanan Alatawi
Samia Abdullah AlsefriSamia Abdullah Alsefri
Samia Abdullah Alsefri
EMEric Moore
Eric Moore
In this study, an in situ synthesis approach based on electrochemical reduction and ion exchange was employed to detect carbaryl species using a disposable, screen-printed carbon electrode fabricated with nanocomposite materials. Reduced graphene oxide (rGO) was used to create a larger electrode surface and more active sites. Gold nanoparticles (AuNPs,) were incorporated to accelerate electron transfer and enhance sensitivity. A cation exchange Nafion polymer was used to enable the adhesion of rGO and AuNPs to the electrode surface and speed up ion exchange. Cyclic voltammetry (CV), energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), electrical impedance spectroscopy (EIS), atomic force microscopy (AFM) and scanning electron microscopy (SEM) were performed to study the electrochemical and physical properties of the modified sensor. In the presence of differential pulse voltammetry (DPV), an rGO/AuNP/Nafion-modified electrode was effectively used to measure the carbaryl concentration in river and tap water samples. The developed sensor exhibited superior electrochemical performance in terms of reproducibility, stability, efficiency and selectivity for carbaryl detection with a detection limit of 0.2 µM and a concentration range between 0.5µM and 250 µM. The proposed approach was compared to capillary electrophoresis with ultraviolet detection (CE-UV).

11 January 2023 in Analytical Methods
Verified
Journal Article
Open access
PDF file
HAHanan Alatawi
Hanan Alatawi
AHAnna Hogan
Anna Hogan
IAibtihaj eid abalawi
ibtihaj eid abalawi
SASamia Alsefri
Samia Alsefri
EMEric Moore
Eric Moore
Recently, non-steroidal anti-inflammatory drugs (NSAIDs) have been increasingly used in humans and animals.

12 April 2023 in Separations
Verified
Journal Article
Open access
PDF file
Samia Abdullah AlsefriSamia Abdullah Alsefri
Samia Abdullah Alsefri
TBThanih Balbaied
Thanih Balbaied
HAHanan Alatawi
Hanan Alatawi
IAibtihaj eid abalawi
ibtihaj eid abalawi
AHAnna Hogan
Anna Hogan
EMEric Moore
Eric Moore
Polychlorinated biphenyls (PCBs) have been found in soil, which has typically been the result of industrial pollution in the past two decades. Although they are banned, PCBs can still be found in soils and other environmental media. For this reason, it is critical to develop an analytical method that can reliably identify and monitor their sources. This study describes a gas chromatography with mass spectrometry (GC-MS) technique, which was used to detect PCBs in soil samples by using a fast extraction method. Using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) method, PCBs were more effectively extracted from soil. Different related parameters, such as time of shaking and centrifuging, type of solvent, and clean-up adsorbents, were compared and optimized. As the extraction solvent, acetonitrile/water produced the best results, and as the dispersive solid-phase extraction sorbent, diatomaceous earth produced the best results. Procedures allowed recovery values between 95.3% and 103.2%. A limit of detection of 1.9 µg/kg was determined with relative standard deviations (n = 3) of 2.1–4.0% for intra-day assays and 3.6–5.8% for inter-day assays. It was demonstrated that the method was simple, sensitive, efficient, and environmentally friendly when applied to soil samples. To our knowledge, an integrated approach based on QuEChERS for the determination of Aroclor 1254 in soil has not been published before. It is believed that this approach will eliminate the significant challenge of sample extraction in GC-MS processing, which was considered to be a procedural challenge in previous analyses.

22 August 2022 in Electrochem
Verified
Journal Article
Open access
PDF file
Samia Abdullah AlsefriSamia Abdullah Alsefri
Samia Abdullah Alsefri
TBThanih Balbaied
Thanih Balbaied
IAibtihaj eid abalawi
ibtihaj eid abalawi
HAHanan Alatawi
Hanan Alatawi
EMEric Moore
Eric Moore
PCBs (polychlorinated biphenyls) are a very large group of organic compounds that have between two and ten chlorine atoms attached to the biphenyl. These compounds have an acute impact as environmental pollutants, causing cancer and other adverse health effects in humans. It is therefore imperative to develop techniques for the cost-effective detection of PCBs at very low concentrations in ecosystems. In this paper, a novel label-free, indirect, competitive electrochemical immunosensor was first developed with a PCB-BSA conjugate. It is shown herein to compete with free PCBs for binding to the anti-PCB polyclonal primary antibody (IgY). Then, we used a secondary antibody to enhance the sensitivity of the sensor for the detection of PCB in a sample. It has been successfully immobilized on an 11-mercaptoundecanoic acid (11-MUA)-modified gold electrode via a carbodiimide-coupling reaction using cross-linking 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) on the electrode surface. The immunosensor was investigated by cyclic voltammetry and differential pulse voltammetry in a standard solution of [Fe(CN)6]3−/4−. A linear range of 0.011–220 ng/mL−1 and a limit of detection (LOD) of 0.11 ng/mL−1 for PCBs detection were achieved by the developed immunosensor, showing advantages over conventional assays. The novel label-free electrochemical immunosensor discussed in this paper is a solution for simple, rapid, cost-effective sample screening in a portable, disposable format. The proposed immunosensor has good sensitivity, and it can prove to be an adequate real-time monitoring solution for PCBs in soil samples or other samples.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
IAibtihaj eid abalawi
ibtihaj eid abalawi
AHAnna Hogan
Anna Hogan
HAHanan Alatawi
Hanan Alatawi
SASamia Alsefri
Samia Alsefri
EMEric Moore
Eric Moore
A novel and effective method for immobilization of active ruthenium (II) bipyridine complex on screen printed gold electrode surface was developed for simultaneous determination of Cd (II) and Pb (II) in an environmental water sample. The electrostatic interaction between negatively charged graphene (GO) oxide or citrate-capped gold nanoparticles (AuNPs) and positively charged Ru-(bpy) 3 Cl 2 was studied with the incorporation of cation exchanging Nafion polymer, which enhanced electron transfer rate, reduced the interference caused by active compounds and results in long term stability. The comparison between the hybrid Ru-GO/Nafion and Ru-Au/Nafion nanocomposites behavior was electrochemically investigated in this paper through cyclic voltammetry (CV), Impedance spectroscopy (IES), and anodic stripping square wave voltammetry (ASWV). Additionally, the surface morphologies of the screen-printed electrode were evaluated using energy dispersive X-ray spectroscopy (EDX) and scanning electron microscopy (SEM). The proposed Ru-GO/Nafion sensor exhibited a higher sensitivity towards cadmium ion with a detection limit of 4.2 ppb compared to the Ru-Au/Nafion assay, which reveals low sensitivity with a limit of detection of 12.01 ppb. The developed assays show excellent electrochemical performance towards lead ions with a detection limit of 5.3 ppb and 2.5 ppb for Ru-GO/Nafion and Ru-Au/Nafion, respectively, indicating that the lead ions can be accumulated more on the surface of Ru-Au/Nafion SPGE. The hybrid nanocomposites assays were successfully employed in river and tap water samples and validated using Atomic Absorption Spectroscopy (AAS).