This paper presents the prelaunch radiometric calibration of the Ozone Monitor Suite-Nadir (OMS-N) instrument, a vital payload on the FY-3F satellite. FY-3F achieved a successful launch on 3 August 2023. The radiance calibration of the OMS-N instrument was achieved using an integrating sphere, with known exit radiance ascertained through a transferring radiometer. The calibration model incorporates six energy levels. The Solar Simulator Standard System was employed to validate the calibration results, selecting specific rows to represent varying spatial dimensions. Considering the influence of xenon lamp characteristic peaks and transmission errors during the calibration process, the average deviation remained within 2.3% for the VIS channel, 3% for the UV1 channel, and 2.2% for the UV2 channel. Furthermore, the uncertainty of the radiometric calibration was analyzed. The results indicated an absolute uncertainty of 2.33% for both the UV1 and UV2 channels and 1.69% for the VIS channel. The relative uncertainty was 1.84% for both the UV1 and UV2 channels and 1.45% for the VIS channel. The obtained calibration coefficients are accurate and reliable and can be used for the inversion of product parameters, which is of great significance to the quantitative application of satellite data and the advancement of scientific research on quantitative remote sensing.
This paper presents the prelaunch radiometric calibration of the Ozone Monitor Suite - Nadir (OMS-N) instrument, a vital payload on the FY-3F satellite. FY-3F achieved a successful launch on August 3, 2023. The radiance calibration of the OMS-N instrument was achieved using an integrating sphere, with known exit radiance ascertained through a transferring radiometer. The calibration model incorporates six energy levels. The Solar Simulator Standard System was employed to validate the calibration results, selecting specific rows to represent varying spatial dimensions. Considering the influence of xenon lamp characteristic peaks and transmission errors during the calibration process, the average deviation remained within 2.3% for the UVIS channel, 3% for the UV1 channel, and 2.2% for the UV2 channel. Furthermore, this study analyzed the uncertainty of the radiometric calibration. The results indicated an absolute uncertainty of 2.32% for both UV1 and UV2 channels, while the VIS channel exhibited an uncertainty of 1.67%. The relative uncertainty was 1.84% for both UV1 and UV2 channels, with the VIS channel exhibiting an uncertainty of 1.45%. The obtained calibration coefficients are accurate and reliable and can be used for the inversion of product parameters, which is of great significance to the quantitative application of satellite data and the advancement of scientific research on quantitative remote sensing.
The spectra measured by the Atmospheric Carbon dioxide Grating Spectrometer (ACGS) carried by the China global carbon dioxide observation satellite (TanSat) in the band of 0.76 μm, 1.61 μm and 2.06 μm can be used for the retrieval of carbon dioxide (CO2) concentrations by fitting the observations and simulations using the optimal estimation algorithm. Accurately detecting the change of the center wavelength is highly important because of its very high spectral resolution and accuracy requirement for product retrieval. The variations of center wavelength for all three bands of ACGS have been calculated on the locations of the individual solar absorption lines by comparing the solar-viewing measurements and the high resolution solar reference spectrum. The variations with magnitudes less than 10 % of the spectral resolution for each band have been detected. The changes are probably caused by vibration and the instrument status difference between the ground and space, especially temperature variation on orbit. In addition to solar lines, the entire atmospheric spectra simulated by radiative transfer model can be used as the reference spectrum to determine the wavelength change by fitting the measured and simulated spectra. The change of wavelength determined by atmospheric spectra is closely consistent with that by solar lines. Both schemes described here can be used not only for monitoring spectral stability but also to gain spectral knowledge prior to the level-2 product processing. These minor temporal changes of wavelength on orbit should be corrected in the product retrieval.