Cheng-Kung Cheng

Prof. Dr. Cheng-Kung Cheng

School of Biomedical Engineering Director, Engineering Research Center of Digital Medicine and Clinical Translation of the Ministry of Education, Shanghai Jiao Tong University, Shanghai 200030, China
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
PWPei-Chun Wong
Pei-Chun Wong
PTPei-Hua Tsai
Pei-Hua Tsai
TLTsung-Hsiung Li
Tsung-Hsiung Li
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
JJJ.S.C. Jang
J.S.C. Jang
JHJacob Huang
Jacob Huang

1 January 2018 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
YWYan Wang
Yan Wang
ZLZengyong Li
Zengyong Li
DWDuo Wai-Chi Wong
Duo Wai-Chi Wong
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
MZMing Zhang
Ming Zhang
Total ankle arthroplasty is gaining popularity as an alternation to ankle arthrodesis for end-stage ankle arthritis. Owing to the complex anatomical characteristics of the ankle joint, total ankle arthroplasty has higher failure rates. Biomechanical exploration of the effects of total ankle arthroplasty on the foot and ankle is imperative for the precaution of postoperative complications. The objectives of this study are (1) to investigate the biomechanical differences of the foot and ankle between the foot with total ankle arthroplasty and the intact foot and (2) to investigate the performance of the three-component ankle prosthesis. To understand the loading environment of the inner foot, comprehensive finite element models of an intact foot and a foot with total ankle arthroplasty were developed to simulate the stance phase of gait. Motion analysis on the model subject was conducted to obtain the boundary and loading conditions. The model was validated through comparison of plantar pressure and joint contact pressure between computational prediction and experimental measurement. A pressure mapping system was used to measure the plantar pressure during balanced standing and walking in the motion analysis experiment, and joint contact pressure at the talonavicular joint was measured in a cadaver foot. Plantar pressure, stress distribution in bones and implants and joint contact loading in the two models were compared, and motion of the prosthesis was analysed. Compared with the intact foot model, averaged contact pressure at the medial cuneonavicular joint increased by 67.4% at the second-peak instant. The maximum stress in the metatarsal bones increased by 19.8% and 31.3% at the mid-stance and second-peak instants, respectively. Force that was transmitted in three medial columns was 0.33, 0.53 and 1.15 times of body weight, respectively, at the first-peak, mid-stance and second-peak instants. The range of motion of the prosthetic ankle was constrained in the frontal plane. The lateral side of the prosthesis sustained higher loading than the medial side. Total ankle arthroplasty resulted in great increase of contact pressure at the medial cuneonavicular joint, making it sustain the highest contact pressure among all joints in the foot. The motion of the prosthesis was constrained in the frontal plane, and asymmetric loading was distributed in the bearing component of the ankle prosthesis in the mediolateral direction. Biomechanical variations resulted from total ankle arthroplasty may contribute to negative postoperative outcomes. The exploration of the biomechanical performance in this study might benefit the surgeons in the determination of surgical protocols to avoid complications. The analysis of the performance of the ankle prosthesis could enhance the knowledge of prosthetic design.

5 January 2007 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CHChun-Hsiung Huang
Chun-Hsiung Huang
JLJiann-Jong Liau
Jiann-Jong Liau
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing.

17 November 2021 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
BLBolun Liu
Bolun Liu
HWHuizhi Wang
Huizhi Wang
NZNingze Zhang
Ningze Zhang
MZMin Zhang
Min Zhang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng
Cementless femoral stems are prone to stress shielding of the femoral bone, which is caused by a mismatch in stiffness between the femoral stem and femur. This can cause bone resorption and resultant loosening of the implant. It is possible to reduce the stress shielding by using a femoral stem with porous structures and lower stiffness. A porous structure also provides a secondary function of allowing bone ingrowth, thus improving the long-term stability of the prosthesis. Furthermore, due to the advent of additive manufacturing (AM) technology, it is possible to fabricate femoral stems with internal porous lattices. Several review articles have discussed porous structures, mainly focusing on the geometric design, mechanical properties and influence on bone ingrowth. However, the safety and effectiveness of porous femoral stems depend not only on the characteristic of porous structure but also on the macro design of the femoral stem; for example, the distribution of the porous structure, the stem geometric shape, the material, and the manufacturing process. This review focuses on porous femoral stems, including the porous structure, macro geometric design of the stem, performance evaluation, research methods used for designing and evaluating the femoral stems, materials and manufacturing techniques. In addition, this review will evaluate whether porous femoral stems can reduce stress shielding and increase bone ingrowth, in addition to analyzing their shortcomings and related risks and providing ideas for potential design improvements.

1 December 2014 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
CCChih-Yu Chen
Chih-Yu Chen
CHChia-Chian Hu
Chia-Chian Hu
PWPei-Wei Weng
Pei-Wei Weng
YHYu-Ming Huang
Yu-Ming Huang
CCChang-Jung Chiang
Chang-Jung Chiang
Cheng-Kung ChengCheng-Kung Cheng
Cheng-Kung Cheng

3 June 2014 in Medical Engineering & Physics
Verified
Journal Article
Closed access
YCYi-Long Chen
Yi-Long Chen
WCWen-Chuan Chen
Wen-Chuan Chen
CCChi-Wei Chou
Chi-Wei Chou
JCJou-Wen Chen
Jou-Wen Chen
CCChia-Ming Chang
Chia-Ming Chang
SWShih-Tien Wang
Shih-Tien Wang
Pedicle screws are widely utilized to treat the unstable thoracolumbar spine. The superior biomechanical strength of pedicle screws could increase fusion rates and provide accurate corrections of complex deformities. However, osteoporosis and revision cases of pedicle screw substantially reduce screw holding strength and cause loosening. Pedicle screw fixation becomes a challenge for spine surgeons in those scenarios. The purpose of this study was to determine if an expandable pedicle screw design could be used to improve biomechanical fixation in osteoporotic bone. Axial mechanical pull-out test was performed on the expandable, conventional and augmented pedicle screws placed in a commercial synthetic bone block which mimicked a human bone with severe osteoporosis. Results revealed that the pull-out strength and failure energy of expandable pedicle screws were similar with conventional pedicle screws augmented with bone cement by 2 ml. The pull-out strength was 5-fold greater than conventional pedicle screws and the failure energy was about 2-fold greater. Besides, the pull-out strength of expandable screw was reinforced by the expandable mechanism without cement augmentation, indicated that the risks of cement leakage from vertebral body would potentially be avoided. Comparing with the biomechanical performances of conventional screw with or without cement augmentation, the expandable screws are recommended to be applied for the osteoporotic vertebrae.