Michelle Feijen

Ms. Michelle Feijen

Leiden University Medical Center (LUMC), The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MFMichelle Feijen
Michelle Feijen
AEAnastasia D. Egorova
Anastasia D. Egorova
SBSaskia L.M.A. Beeres
Saskia L.M.A. Beeres
RTRoderick W Treskes
Roderick W Treskes
Heart failure (HF) hospitalisations due to decompensation are associated with shorter life expectancy and lower quality of life. These hospitalisations pose a significant burden on the patients, doctors and healthcare resources. Early detection of an upcoming episode of decompensation may facilitate timely optimisation of the ambulatory medical treatment and thereby prevent heart-failure-related hospitalisations. The HeartLogicTM algorithm combines data from five sensors of cardiac implantable electronic devices into a cumulative index value. It has been developed for early detection of fluid retention in heart failure patients. This review aims to provide an overview of the current literature and experience with the HeartLogicTM algorithm, illustrate how the index can be implemented in daily clinical practice and discuss ongoing studies and potential future developments of interest.

21 May 2023 in Journal of Cardiac Failure
Verified
Journal Article
Open access
MFMichelle Feijen
Michelle Feijen
MBMonika Beles
Monika Beles
YTYan Zhi Tan
Yan Zhi Tan
ACAudrey Cordon
Audrey Cordon
MDMatthias Dupont
Matthias Dupont
WHWard A. Heggermont
Ward A. Heggermont
The implantable cardiac defibrillator (ICD) based HeartLogicTM algorithm aims to detect impending fluid retention in heart failure (HF) patients. Studies show that HeartLogicTM is safe to integrate in clinical practice. The current study investigates if HeartLogicTM provides clinical benefit on top of standard care and device telemonitoring in HF patients. A multicenter retrospective propensity-matched cohort analysis was performed in HF patients with and ICD and compared HeartLogicTM to conventional telemonitoring. Primary endpoint was the number of worsening HF events. HF hospitalizations and ambulatory HF visits were also evaluated. Propensity score matching yielded 127 pairs (median age 68 years, 80% male). Worsening HF events occurred more frequently in the control group (2, IQR 0-4) compared to the HeartLogicTM group (1, IQR 0-3, p=0.004). The number of HF hospitalization days was higher in controls compared to the HeartLogicTM group (8, IQR 5-12 vs. 5, IQR 2-7, p=0.023) and ambulatory visits for diuretic escalation were more frequent in the control group than in the HeartLogicTM group (2, IQR 0-3 vs. 1, IQR 0-2, p=0.0001). Integrating the HeartLogicTM algorithm in a well-equipped HF care path on top of standard care, is associated with fewer worsening HF events and shorter duration of fluid retention related hospitalizations.

30 August 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MFMichelle Feijen
Michelle Feijen
AEAnastasia D. Egorova
Anastasia D. Egorova
TKTeresa Kuijken
Teresa Kuijken
MBMarianne Bootsma
Marianne Bootsma
MSMartin J. Schalij
Martin J. Schalij
LELieselot van Erven
Lieselot van Erven
Implantable cardioverter defibrillators (ICDs) significantly contribute to the prevention of sudden cardiac death in selected patients. However, it is essential to identify those who are likely to not have benefit from an ICD and to defer a pulse generator exchange. Easily implementable guidelines for individual risk stratification and decision making are lacking. This study investigates the 1-year mortality of patients who underwent an ICD or cardiac resynchronization therapy with defibrillator function (CRT-D) pulse generator replacement in a contemporary real-world tertiary hospital setting. The cause of death and patient- and procedure-related factors are stratified, and predictive values for 1-year mortality are evaluated. Patients with a follow-up of ≥365 days (or prior mortality) after an ICD or CRT-D exchange at the Leiden University Medical Center from 1 January 2018 until 31 December 2021 were eligible. In total, 588 patients were included (77% male, 69 [60–76] years old, 59% primary prevention, 46% ischemic cardiomyopathy and 37% mildly reduced left ventricular ejection fraction (LVEF)). Patients undergoing a CRT-D replacement or upgrade had a significantly higher 1-year all-cause mortality (10.7% and 11.9%, respectively) compared to patients undergoing ICD (2.8%) exchange (p = 0.002). LVEF ≤ 30%, New York Heart Association class ≥ 3, estimated glomerular filtration rate ≤ 30 mL/min/m2 and haemoglobin ≤ 7 mmol/L were independently associated with mortality within 1 year after pulse generator replacement. There is a growing need for prospectively validated risk scores to weight individualized risk of mortality with the expected ICD therapy benefit and to support a well-informed, shared decision-making process.

1 July 2025 in Current Heart Failure Reports
Verified
Journal Article
Open access
PDF file
BZBert A. C. Zwaenepoel
Bert A. C. Zwaenepoel
AKAnnefleur Kluft
Annefleur Kluft
MFMichelle Feijen
Michelle Feijen
JSJan Schoones
Jan Schoones
WHWard A. Heggermont
Ward A. Heggermont
SBSaskia L.M.A. Beeres
Saskia L.M.A. Beeres
Purpose of Review: Cardiac Implantable Electronic Device (CIED)-based remote monitoring has been proposed to improve heart failure (HF) management by enabling early detection of decompensation. This systematic review evaluates the effectiveness of multisensor CIED-based monitoring in reducing mortality, HF hospitalizations, and unplanned HF outpatient visits. Recent Findings: Earlier CIED-based remote monitoring strategies were mainly based on single-sensor impedance-based algorithms, and showed limited clinical benefits. Newer multisensor CIED-based algorithms have shown promise in initial studies. However, their impact on clinical outcomes remains uncertain, and therefore current HF guidelines provide limited recommendations. Summary: Multisensor CIED-based algorithms reliably identify high-risk HF patients and their use leads to reductions in HF hospitalizations and unplanned outpatient HF visits, although prospective validation in RCTs is lacking for any of the algorithms. Standardized response strategies are needed to enhance clinical integration and generalizability. If validated, multisensor monitoring could become a key tool in HF management.

5 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
UAUgur Aslan
Ugur Aslan
SBSaskia L.M.A. Beeres
Saskia L.M.A. Beeres
MFMichelle Feijen
Michelle Feijen
GMGerlinde M. Mulder
Gerlinde M. Mulder
JJJ. Wouter Jukema
J. Wouter Jukema
AEAnastasia D. Egorova
Anastasia D. Egorova
Heart failure (HF) admissions are burdensome, and the mainstay of prevention is the timely detection of impending fluid retention, creating a window for medical treatment intensification. This study evaluated the accuracy and performance of a Triage-HF-guided carepath in real-world ambulatory HF patients in daily clinical practice. In this prospective, observational study, 92 adult HF patients (71 males (78%), with a median age of 69 [IQR 59–75] years) with the Triage-HF algorithm activated in their cardiac implantable electronic devices (CIEDs), were monitored. Following high-risk alerts, an HF nurse contacted patients to identify signs and symptoms of fluid retention. The sensitivity and specificity were 83% and 97%, respectively. The positive predictive value was 89%, and negative predictive value was 94%. The unexplained alert rate was 0.05 alerts/patient year, and the false negative rate was 0.11 alerts/patient year. Ambulatory diuretics were initiated or escalated in 77% of high-risk alert episodes. In 23% (n = 6), admission was ultimately required. The median alert handling time was 2 days. Fifty-eight percent (n = 18) of high-risk alerts were classified as true positives in the first week, followed by 29% in the second–third weeks (n = 9), and 13% (n = 4) in the fourth–sixth weeks. Common sensory triggers included an elevated night ventricular rate (84%), OptiVol (71%), and reduced patient activity (71%). The CIED-based Triage-HF algorithm-driven carepath enables the timely detection of impending fluid retention in a contemporary ambulatory setting, providing an opportunity for clinical action.

9 January 2026 in JACC: Heart Failure
Verified
Journal Article
Open access
UAUgur Aslan
Ugur Aslan
BZBert A.C. Zwaenepoel
Bert A.C. Zwaenepoel
BKBas Kirchhof
Bas Kirchhof
BMBart J.A. Mertens
Bart J.A. Mertens
MFMichelle Feijen
Michelle Feijen
SBSaskia L.M.A. Beeres
Saskia L.M.A. Beeres