Ilze Lihacova

Mrs. Ilze Lihacova

University of Latvia, Riga, Rīga, Latvia
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
ALAlexey Lihachev
Alexey Lihachev
ILIlze Lihacova
Ilze Lihacova
EPEmilija V. Plorina
Emilija V. Plorina
MLMarta Lange
Marta Lange
ADAlexander Derjabo
Alexander Derjabo
JSJanis Spigulis
Janis Spigulis
A clinical trial on the autofluorescence imaging of skin lesions comprising 16 dermatologically confirmed pigmented nevi, 15 seborrheic keratosis, 2 dysplastic nevi, histologically confirmed 17 basal cell carcinomas and 1 melanoma was performed. The autofluorescence spatial properties of the skin lesions were acquired by smartphone RGB camera under 405 nm LED excitation. The diagnostic criterion is based on the calculation of the mean autofluorescence intensity of the examined lesion in the spectral range of 515 nm–700 nm. The proposed methodology is able to differentiate seborrheic keratosis from basal cell carcinoma, pigmented nevi and melanoma. The sensitivity and specificity of the proposed method was estimated as being close to 100%. The proposed methodology and potential clinical applications are discussed in this article.

15 November 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
APArturo Pardo
Arturo Pardo
JGJosé Alberto Gutiérrez
José Alberto Gutiérrez
ILIlze Lihacova
Ilze Lihacova
Jose Lopez-HigueraJose Lopez-Higuera
Jose Lopez-Higuera
OPOlga María Portilla
Olga María Portilla
Early detection and diagnosis is a must in secondary prevention of melanoma and other cancerous lesions of the skin. In this work, we present an online, reservoir-based, non-parametric estimation and classification model that allows for this functionality on pigmented lesions, such that detection thresholding can be tuned to maximize accuracy and/or minimize overall false negative rates. This system has been tested in a dataset consisting of 116 patients and a total of 124 hyperspectral images of nevi, raised nevi and melanomas, detecting up to 100% of the suspicious lesions at the expense of some false positives.

1 December 2015 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
ALAlexey Lihachev
Alexey Lihachev
ADAlexander Derjabo
Alexander Derjabo
IFInesa Ferulova
Inesa Ferulova
MLMarta Lange
Marta Lange
ILIlze Lihacova
Ilze Lihacova
JSJanis Spigulis
Janis Spigulis
The feasibility of smartphones for in vivo skin autofluorescence imaging has been investigated. Filtered autofluorescence images from the same tissue area were periodically captured by a smartphone RGB camera with subsequent detection of fluorescence intensity decreasing at each image pixel for further imaging the planar distribution of those values. The proposed methodology was tested clinically with 13 basal cell carcinoma and 1 atypical nevus. Several clinical cases and potential future applications of the smartphone-based technique are discussed.

28 December 2023 in Cancers
Verified
Journal Article
Open access
PDF file
NVNoémi Nóra Varga
Noémi Nóra Varga
MBMehdi Boostani
Mehdi Boostani
KFKlára Farkas
Klára Farkas
BABanvolgyi Andras
Banvolgyi Andras
KLKende Lőrincz
Kende Lőrincz
Norbert KissNorbert Kiss
Norbert Kiss
Melanoma is the most aggressive form of skin cancer that is known for its metastatic potential and has an increasing incidence worldwide. Breslow thickness, which determines the staging and surgical margin of the tumor, is unavailable at initial diagnosis. Novel imaging techniques for assessing Breslow thickness lack comparative data. This study evaluates optically guided high-frequency ultrasound (OG-HFUS) and multispectral imaging (MSI) for preoperative estimation of Breslow thickness and staging. We enrolled 101 patients with histologically confirmed primary melanoma and categorized them based on tumor thickness. Optically guided 33 MHz HFUS and MSI were utilized for the assessment. Our MSI-based algorithm categorized melanomas into three subgroups with a sensitivity of 62.6%, specificity of 81.3%, and fair agreement (κ = 0.440, CI: 0.298–0.583). In contrast, OG-HFUS demonstrated a sensitivity of 91.8%, specificity of 96.0%, and almost perfect agreement (κ = 0.858, CI: 0.763–0.952). OG-HFUS performed better than MSI in estimating Breslow thickness, emphasizing its potential as a valuable tool for melanoma diagnosis and patient management. OG-HFUS holds promise for enhancing preoperative staging and treatment decision-making in melanoma.

24 February 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
IBIlya Balmages
Ilya Balmages
JLJanis Liepins
Janis Liepins
SZStivens Zolins
Stivens Zolins
DBDmitrijs Bliznuks
Dmitrijs Bliznuks
ILIlze Lihacova
Ilze Lihacova
ALAlexey Lihachev
Alexey Lihachev
In this study, an optical contactless laser speckle imaging technique for the early identification of bacterial colony-forming units was tested. The aim of this work is to compare the laser speckle imaging method for the early assessment of microbial activity with standard visual inspection under white light illumination. In presented research, the growth of Vibrio natriegens bacterial colonies on the solid medium was observed and analyzed. Both – visual examination under white light illumination and laser speckle correlation analysis were performed. Based on various experiments and comparisons with the theoretical Gompertz model, colony radius growth curves were obtained. It was shown that the Gompertz model can be used to describe both types of analysis. A comparison of the two methods shows that laser speckle contrast imaging, combined with signal processing, can detect colony growth earlier than standard CFU counting method under white light illumination.

Verified
Journal Article
Open access
PDF file
ILIlze Lihacova
Ilze Lihacova
ABAndrey Bondarenko
Andrey Bondarenko
YCYuriy Chizhov
Yuriy Chizhov
DUDilshat Uteshev
Dilshat Uteshev
DBDmitrijs Bliznuks
Dmitrijs Bliznuks
ALAlexey Lihachev
Alexey Lihachev
In this work, we propose to use an artificial neural network to classify limited data of clinical multispectral and autofluorescence images of skin lesions. Although the amount of data is limited, the deep convolutional neural network classification of skin lesions using a multi-modal image set is studied and proposed for the first time. The unique dataset consists of spectral reflectance images acquired under 526 nm, 663 nm, 964 nm, and autofluorescence images under 405 nm LED excitation. The augmentation algorithm was applied for multi-modal clinical images of different skin lesion groups to expand the training datasets. It was concluded from saliency maps that the classification performed by the convolutional neural network is based on the distribution of the major skin chromophores and endogenous fluorophores. The resulting classification confusion matrices, as well as the performance of trained neural networks, have been investigated and discussed.