The Imaging and Medical Beamline (IMBL) is a superconducting multipole wiggler-based beamline at the 3 GeV Australian Synchrotron operated by the Australian Nuclear Science and Technology Organisation (ANSTO). The beamline delivers hard X-rays in the 25–120 keV energy range and offers the potential for a range of biomedical X-ray applications, including radiotherapy and medical imaging experiments. One of the imaging modalities available at IMBL is propagation-based X-ray phase-contrast computed tomography (PCT). PCT produces superior results when imaging low-density materials such as soft tissue (e.g., breast mastectomies) and has the potential to be developed into a valuable medical imaging tool. We anticipate that PCT will be utilized for medical breast imaging in the near future with the advantage that it could provide better contrast than conventional X-ray absorption imaging. The unique properties of synchrotron X-ray sources such as high coherence, energy tunability, and high brightness are particularly well-suited for generating PCT data using very short exposure times on the order of less than 1 min. The coherence of synchrotron radiation allows for phase-contrast imaging with superior sensitivity to small differences in soft-tissue density. Here we also compare the results of PCT using two different detectors, as these unique source characteristics need to be complemented with a highly efficient detector. Moreover, the application of phase retrieval for PCT image reconstruction enables the use of noisier images, potentially significantly reducing the total dose received by patients during acquisition. This work is part of ongoing research into innovative tomographic methods aimed at the introduction of 3D X-ray medical imaging at the IMBL to improve the detection and diagnosis of breast cancer. Major progress in this area at the IMBL includes the characterization of a large number of mastectomy samples, both normal and cancerous, which have been scanned at clinically acceptable radiation dose levels and evaluated by expert radiologists with respect to both image quality and cancer diagnosis.
The first new beamline of the BRIGHT project—involving the construction of eight new beamlines at the Australian Synchrotron—is the Micro-Computed Tomography (MCT) beamline. MCT will extend the facility’s capability for higher spatial resolution X-ray-computed tomographic imaging allowing for commensurately smaller samples in comparison with the existing Imaging and Medical Beamline (IMBL). The source is a bending-magnet and it is operating in the X-ray energy range from 8 to 40 keV. The beamline provides important new capability for a range of biological and material-science applications. Several imaging modes will be offered such as various X-ray phase-contrast modalities (propagation-based, grating-based, and speckle-based), in addition to conventional absorption contrast. The unique properties of synchrotron radiation sources (high coherence, energy tunability, and high brightness) are predominantly well-suited for producing phase contrast data. An update on the progress of the MCT project in delivering high-spatial-resolution imaging (in the order of micron size) of mm-scale objects will be presented in detail with some imaging results from the hot-commissioning stage.
The majority of current laboratory based X-ray sources are polychromatic and are not tuneable. This lack of monochromaticity limits the range of applications for these sources and in particular it reduces the elemental specificity of laboratory based X-ray imaging experiments. Here we present a solution to this problem based on the use of Ross filter pairs. Although such Ross filter arrangements have been applied in proof-of-principle spectroscopy experiments, to date there have been no reports of this approach used for full-field X-ray imaging. Here we report on the experimental demonstration of Ross filter pairs being used for quasi-monochromatic, full-field imaging. This arrangement has several important benefits for laboratory based X-ray imaging including, as we demonstrate, elemental contrast enhancement. The method is demonstrated both for two-dimensional radiography and for three-dimensional X-ray tomography.