Photoplethysmographic (PPG) signals are mainly employed for heart rate estimation but are also fascinating candidates in the search for cardiovascular biomarkers. However, their high susceptibility to motion artifacts can lower their morphological quality and, hence, affect the reliability of the extracted information. Low reliability is particularly relevant when signals are recorded in a real-world context, during daily life activities. We aim to develop two classifiers to identify PPG pulses suitable for heart rate estimation (Basic-quality classifier) and morphological analysis (High-quality classifier). We collected wrist PPG data from 31 participants over a 24 h period. We defined four activity ranges based on accelerometer data and randomly selected an equal number of PPG pulses from each range to train and test the classifiers. Independent raters labeled the pulses into three quality levels. Nineteen features, including nine novel features, were extracted from PPG pulses and accelerometer signals. We conducted ten-fold cross-validation on the training set (70%) to optimize hyperparameters of five machine learning algorithms and a neural network, and the remaining 30% was used to test the algorithms. Performances were evaluated using the full features and a reduced set, obtained downstream of feature selection methods. Best performances for both Basic- and High-quality classifiers were achieved using a Support Vector Machine (Acc: 0.96 and 0.97, respectively). Both classifiers outperformed comparable state-of-the-art classifiers. Implementing automatic signal quality assessment methods is essential to improve the reliability of PPG parameters and broaden their applicability in a real-world context.
1 January 2018 in International Journal of Cardiology
Background: We calculated the daily cost of implantable cardioverter-defibrillators (ICDs) based on their actual longevity to prove whether the up-front cost is a reliable parameter for the ICD purchasing-process.Methods. Longevity of single chamber (SC), double chamber (DC), and biventricular (BiV) ICDs from Medtronic (MDT), Guidant (GDT), and St. Jude Medical (SJM) was measured in all the patients implanted in years 2000, 2001, 2002 who reached device replacement within December 31, 2009. The cost of each ICD (device + lead/s) was normalized for its own longevity. Data are expressed as median (25th–75th percentile).Results: A total of 123/153 patients completed the study, 70 percent being alive 8 years after implantation. MDT devices had a superior longevity compared with GDT and SJM (p < .001). Fifty-eight percent of replaced ICDs had a service life at least 1 year shorter than the manufacturers' prediction. Longer-lasting devices had a significantly lower daily cost: €4.8 (4.6–5.7) versus €6.8 (6.2–9.2) and €6.9 (6.2–7.6) for SC (p < .001); €6.9 (6.8–7.7) versus €12.6 (11.8–13.3) and €13.4 (10.3–16.1) for DC; €8.5 (8.3–10.3) versus €15.4 (15.1–15.8) and €14.6 (14.1–14.9) for BiV (p < .005).Conclusions: The true cost of ICD treatment is strictly dependent on device longevity, whereas device up-front cost is unreliable. This aspect should be valued in the technology purchasing process, and could set the basis for an outcome-based reimbursement system. Our observations may be the benchmark respectively for ICD longevity and daily ICD cost in future comparisons. Independent observations in the real-life scenario are needed to properly value newer technologic improvements.
1 June 2018 in International Journal of Cardiology
Background/Objectives: Right ventricular pacing (RVP), leadless pacing (LL), and conduction system pacing (CSP) are treatment options for atrioventricular block (AVB), each with distinct characteristics. However, the long-term outcomes of these pacing strategies remain insufficiently compared. This study evaluates clinical and echocardiographic outcomes of patients with AVB treated with dual chamber RVP, His bundle pacing (HBP), or LL. Methods: This single-center observational registry study included 22 consecutive patients receiving LL with atrioventricular resynchronization functionality (October 2020 to October 2022), matched with 66 control patients receiving either RVP (33 patients) or HBP (33 patients) using propensity score matching (2:3:3 ratio). Primary and secondary endpoints included all-cause mortality, cardiovascular mortality, heart failure, and echocardiographic outcomes. Atrioventricular synchrony in the LL group was assessed. Results: At two years, all-cause mortality was significantly higher in the LL group compared to RVP (36.4% vs. 6.1%, p = 0.002) and HBP (36.4% vs. 12.1%, p = 0.03), but LL had a more severe clinical profile. Cardiovascular mortality and heart failure incidence showed no significant differences. Patients receiving RVP showed a significant decrease in left ventricular ejection fraction and an increase in ventricular volumes. In contrast, HBP patients exhibited favorable cardiac remodeling. Stratification based on atrial sensing showed that LL patients with >66% AV synchrony had a lower mortality (p = 0.02). Conclusions: CSP offers superior results compared to other pacing methods in terms of ventricular function owing to a physiological ventricular activation and maintenance of AV synchrony. However, LL may be a viable alternative for frail and high-risk patients, as the suboptimal AV synchrony is traded off with lesser ventricular dyssynchrony.
About Me
Medical doctor, electrophysiologis, interventional cardiologist
Medical doctor, electrophysiologis, interventional cardiologist