Giulia Massaro

Dr. Giulia Massaro

Università di Bologna, Italy
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SMSerena Moscato
Serena Moscato
SGStella Lo Giudice
Stella Lo Giudice
GMGiulia Massaro
Giulia Massaro
Lorenzo ChiariLorenzo Chiari
Lorenzo Chiari
Photoplethysmographic (PPG) signals are mainly employed for heart rate estimation but are also fascinating candidates in the search for cardiovascular biomarkers. However, their high susceptibility to motion artifacts can lower their morphological quality and, hence, affect the reliability of the extracted information. Low reliability is particularly relevant when signals are recorded in a real-world context, during daily life activities. We aim to develop two classifiers to identify PPG pulses suitable for heart rate estimation (Basic-quality classifier) and morphological analysis (High-quality classifier). We collected wrist PPG data from 31 participants over a 24 h period. We defined four activity ranges based on accelerometer data and randomly selected an equal number of PPG pulses from each range to train and test the classifiers. Independent raters labeled the pulses into three quality levels. Nineteen features, including nine novel features, were extracted from PPG pulses and accelerometer signals. We conducted ten-fold cross-validation on the training set (70%) to optimize hyperparameters of five machine learning algorithms and a neural network, and the remaining 30% was used to test the algorithms. Performances were evaluated using the full features and a reduced set, obtained downstream of feature selection methods. Best performances for both Basic- and High-quality classifiers were achieved using a Support Vector Machine (Acc: 0.96 and 0.97, respectively). Both classifiers outperformed comparable state-of-the-art classifiers. Implementing automatic signal quality assessment methods is essential to improve the reliability of PPG parameters and broaden their applicability in a real-world context.

1 January 2018 in International Journal of Cardiology
Verified
Journal Article
Closed access
IDIgor Diemberger
Igor Diemberger
FMFederico Migliore
Federico Migliore
MBMauro Biffi
Mauro Biffi
ACAlberto Cipriani
Alberto Cipriani
EBEmanuele Bertaglia
Emanuele Bertaglia
GBGiuseppe Boriani
Giuseppe Boriani

1 December 2017 in International Journal of Cardiology
Verified
Journal Article
Closed access
Mauro BiffiMauro Biffi
Mauro Biffi
GMGiulia Massaro
Giulia Massaro
ACAndrea Candelora
Andrea Candelora
AAAndrea Angeletti
Andrea Angeletti
CVCinzia Valzania
Cinzia Valzania
MZMatteo Ziacchi
Matteo Ziacchi

27 June 2011 in International Journal of Technology Assessment in Health Care
Verified
Journal Article
Closed access
PDF file
Mauro BiffiMauro Biffi
Mauro Biffi
MZMatteo Ziacchi
Matteo Ziacchi
Matteo BertiniMatteo Bertini
Matteo Bertini
BGBeatrice Gardini
Beatrice Gardini
AMAndrea Mazzotti
Andrea Mazzotti
DCDaniela Corsini
Daniela Corsini
Background: We calculated the daily cost of implantable cardioverter-defibrillators (ICDs) based on their actual longevity to prove whether the up-front cost is a reliable parameter for the ICD purchasing-process.Methods. Longevity of single chamber (SC), double chamber (DC), and biventricular (BiV) ICDs from Medtronic (MDT), Guidant (GDT), and St. Jude Medical (SJM) was measured in all the patients implanted in years 2000, 2001, 2002 who reached device replacement within December 31, 2009. The cost of each ICD (device + lead/s) was normalized for its own longevity. Data are expressed as median (25th–75th percentile).Results: A total of 123/153 patients completed the study, 70 percent being alive 8 years after implantation. MDT devices had a superior longevity compared with GDT and SJM (p < .001). Fifty-eight percent of replaced ICDs had a service life at least 1 year shorter than the manufacturers' prediction. Longer-lasting devices had a significantly lower daily cost: €4.8 (4.6–5.7) versus €6.8 (6.2–9.2) and €6.9 (6.2–7.6) for SC (p < .001); €6.9 (6.8–7.7) versus €12.6 (11.8–13.3) and €13.4 (10.3–16.1) for DC; €8.5 (8.3–10.3) versus €15.4 (15.1–15.8) and €14.6 (14.1–14.9) for BiV (p < .005).Conclusions: The true cost of ICD treatment is strictly dependent on device longevity, whereas device up-front cost is unreliable. This aspect should be valued in the technology purchasing process, and could set the basis for an outcome-based reimbursement system. Our observations may be the benchmark respectively for ICD longevity and daily ICD cost in future comparisons. Independent observations in the real-life scenario are needed to properly value newer technologic improvements.

1 June 2018 in International Journal of Cardiology
Verified
Journal Article
Closed access
IDIgor Diemberger
Igor Diemberger
EFElisa Fantecchi
Elisa Fantecchi
MRMaria Letizia Bacchi Reggiani
Maria Letizia Bacchi Reggiani
CMCristian Martignani
Cristian Martignani
AAAndrea Angeletti
Andrea Angeletti
GBGiuseppe Boriani
Giuseppe Boriani

4 February 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Mauro BiffiMauro Biffi
Mauro Biffi
ABAnnalisa Bagatin
Annalisa Bagatin
ASAlberto Spadotto
Alberto Spadotto
MLMirco Lazzeri
Mirco Lazzeri
ACAlessandro Carecci
Alessandro Carecci
MZMatteo Ziacchi
Matteo Ziacchi
Background/Objectives: Right ventricular pacing (RVP), leadless pacing (LL), and conduction system pacing (CSP) are treatment options for atrioventricular block (AVB), each with distinct characteristics. However, the long-term outcomes of these pacing strategies remain insufficiently compared. This study evaluates clinical and echocardiographic outcomes of patients with AVB treated with dual chamber RVP, His bundle pacing (HBP), or LL. Methods: This single-center observational registry study included 22 consecutive patients receiving LL with atrioventricular resynchronization functionality (October 2020 to October 2022), matched with 66 control patients receiving either RVP (33 patients) or HBP (33 patients) using propensity score matching (2:3:3 ratio). Primary and secondary endpoints included all-cause mortality, cardiovascular mortality, heart failure, and echocardiographic outcomes. Atrioventricular synchrony in the LL group was assessed. Results: At two years, all-cause mortality was significantly higher in the LL group compared to RVP (36.4% vs. 6.1%, p = 0.002) and HBP (36.4% vs. 12.1%, p = 0.03), but LL had a more severe clinical profile. Cardiovascular mortality and heart failure incidence showed no significant differences. Patients receiving RVP showed a significant decrease in left ventricular ejection fraction and an increase in ventricular volumes. In contrast, HBP patients exhibited favorable cardiac remodeling. Stratification based on atrial sensing showed that LL patients with >66% AV synchrony had a lower mortality (p = 0.02). Conclusions: CSP offers superior results compared to other pacing methods in terms of ventricular function owing to a physiological ventricular activation and maintenance of AV synchrony. However, LL may be a viable alternative for frail and high-risk patients, as the suboptimal AV synchrony is traded off with lesser ventricular dyssynchrony.