Xiaotong Zhang

Dr. Xiaotong Zhang

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2019 in Science Advances
Verified
Journal Article
Open access
PDF file
AXAugix Guohua Xu
Augix Guohua Xu
MQMeizhen Qian
Meizhen Qian
FTFeiyan Tian
Feiyan Tian
BXBin Xu
Bin Xu
RFRobert M. Friedman
Robert M. Friedman
ARAnna Wang Roe
Anna Wang Roe
We have developed INS-fMRI as a rapid and high-resolution method for mapping functional brain networks in vivo.

21 July 2022 in Journal of Thermal Science
Verified
Journal Article
Closed access
PDF file
LZLunxiang Zhang
Lunxiang Zhang
MSMingrui Sun
Mingrui Sun
TWTian Wang
Tian Wang
LYLei Yang
Lei Yang
XZXiaotong Zhang
Xiaotong Zhang
YSYongchen Song
Yongchen Song

6 December 2022 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
WCWeidao Chen
Weidao Chen
JWJiangfen Wu
Jiangfen Wu
RWRen Wei
Ren Wei
SWShuang Wu
Shuang Wu
CXChen Xia
Chen Xia
XZXiaotong Zhang
Xiaotong Zhang
Objective: This study aimed to develop a deep learning (DL) model to improve the diagnostic performance of EIC and ASPECTS in acute ischemic stroke (AIS). Methods: Acute ischemic stroke patients were retrospectively enrolled from 5 hospitals. We proposed a deep learning model to simultaneously segment the infarct and estimate ASPECTS automatically using baseline CT. The model performance of segmentation and ASPECTS scoring was evaluated using dice similarity coefficient (DSC) and ROC, respectively. Four raters participated in the multi-reader and multicenter (MRMC) experiment to fulfill the region-based ASPECTS reading under the assistance of the model or not. At last, sensitivity, specificity, interpretation time and interrater agreement were used to evaluate the raters’ reading performance. Results: In total, 1391 patients were enrolled for model development and 85 patients for external validation with onset to CT scanning time of 176.4 ± 93.6 min and NIHSS of 5 (IQR 2–10). The model achieved a DSC of 0.600 and 0.762 and an AUC of 0.876 (CI 0.846–0.907) and 0.729 (CI 0.679–0.779), in the internal and external validation set, respectively. The assistance of the DL model improved the raters’ average sensitivities and specificities from 0.254 (CI 0.22–0.26) and 0.896 (CI 0.884–0.907), to 0.333 (CI 0.301–0.345) and 0.915 (CI 0.904–0.926), respectively. The average interpretation time of the raters was reduced from 219.0 to 175.7 s (p = 0.035). Meanwhile, the interrater agreement increased from 0.741 to 0.980. Conclusions: With the assistance of our proposed DL model, radiologists got better performance in the detection of AIS lesions on NCCT.

25 November 2019 in NeuroImage
Verified
Journal Article
Open access
YGYang Gao
Yang Gao
AMAzma Mareyam
Azma Mareyam
YSYi Sun
Yi Sun
TWThomas Witzel
Thomas Witzel
NANicolas Arango
Nicolas Arango
XZXiaotong Zhang
Xiaotong Zhang
Functional magnetic resonance imaging (fMRI) in monkeys is important for bridging the gap between invasive animal brain studies and non-invasive human brain studies. To resolve the finer functional structure of the monkey brain, ultra-high-field (UHF) MR is essential, and high-performance, close-fitting RF receive coils are typically desired to fully leverage the intrinsic gains provided by UHF MRI. Moreover, static field (B0) inhomogeneity arising from the tissue susceptibility interface is more severe at UHF, presenting an obstacle to achieving high-resolution fMRI. B0 shim of the monkey head is challenging due to its smaller size and more complex sources of B0 offsets in multi-modal imaging tasks. In the present work, we have customized an array coil for lightly-anesthetized monkey fMRI in the 7T human scanner that combines RF and multi-coil (MC) B0 shim functionality (also referred to as AC/DC coils) to provide high imaging SNR and high-spatial-order, rapidly switchable B0-shim capability. Additional space was retained on the coil to render it compatible with monkey multi-modal imaging studies. Both MC global (whole-volume) and dynamic (slice-optimized) shim methods were tested and evaluated, and the benefits of MC shim for fMRI experiments was also studied. A minor reduction in RF coil performance was found after introducing additional B0 shim circuitry. However, the proposed RF coil provided higher image SNR and more uniform contrast compared to a commercially available coil for human knee imaging. Compared with static 2nd-order shim, the B0 inhomogeneity was reduced by 56.8%, and 95-percentile B0 offset was reduced to within 28.2 Hz through MC shim, versus 68.7 Hz with 2nd-order static shim. As a result, functional image quality could be improved, and brain activation can be better detected using the proposed AC/DC monkey coil.

1 January 2022 in Ecotoxicology and Environmental Safety
Verified
Journal Article
Open access
SWShenghang Wang
Shenghang Wang
MZMengxuan Zheng
Mengxuan Zheng
CLChenge Lou
Chenge Lou
SCShuai Chen
Shuai Chen
HGHuijie Guo
Huijie Guo
PSPeng Shang
Peng Shang
This study evaluated the associated biological effects of radio-frequency (RF) exposure at 16 T magnetic resonance imaging (MRI) on mice health. A total of 48 healthy 8-week-old male C57BL/6 mice were investigated. A 16 T high static magnetic field (HiSMF) was generated by a superconducting magnet, and a radiofrequency (RF) electromagnetic field for hydrogen resonance at 16 T (700 MHz) was transmitted via a homemade RF system. The mice were exposed inside the 16 T HiSMF with the 700 MHz RF field for 60 min, and the body weight, organ coefficients, histomorphology of major organs, and blood indices were analyzed for the basal state of the mice on day 0 and day 14. The Heat Shock Protein 70 (HSP70), cyclooxygenase 2 (COX2), and interleukin- 6 (IL-6) were used to evaluate the thermal effects on the brain. Locomotor activity, the open field test, tail suspension test, forced swimming test, and grip strength test were used to assess the behavioral characteristics of the mice. The 16 T HiSMF with 700 MHz RF electromagnetic field exposure had no significant effects on body weight, organ coefficients, or histomorphology of major organs in the mice. On day 0, the expressions of HSP70 and COX2 in the brain were increased by 16 T HiSMF with 700 MHz RF electromagnetic field exposure. However, the expression of HSP70, COX2, and IL-6 had no significant difference compared with the sham group on day 14. Compared with the sham groups, the meancorpuscularvolume (MCV) on day 0 and the total protein (TP) on day 14 were increased significantly, whereas the other blood indices did not change significantly. The 16 T HiSMF with 700 MHz RF electromagnetic field exposure caused the mice to briefly circle tightly but had no effect on other behavioral indicators. In summary, 16 T HiSMF with 700 MHz RF electromagnetic field exposure for 60 min did not have severe effects on mice.

9 December 2021 in Bioelectromagnetics
Verified
Journal Article
Closed access
YZYi Zhang
Yi Zhang
YGYang Gao
Yang Gao
KFKe Fang
Ke Fang
JYJingjing Ye
Jingjing Ye
YRYingheng Ruan
Yingheng Ruan
XZXiaotong Zhang
Xiaotong Zhang