Karoliina Vuorenpää

Ms. Karoliina Vuorenpää

University of Turku
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2020 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
Iida MartiskainenIida Martiskainen
Iida Martiskainen
STSheikh M. Talha
Sheikh M. Talha
Karoliina VuorenpääKaroliina Vuorenpää
Karoliina Vuorenpää
TSTeppo Salminen
Teppo Salminen
EJEtvi Juntunen
Etvi Juntunen
GBGaurav Batra
Gaurav Batra
Detection of hepatitis B Virus surface antigen (HBsAg) is an established method for diagnosing both acute and chronic hepatitis B virus (HBV) infection. In addition to enzyme immunoassays (EIAs), rapid diagnostic tests (RDTs) are available for the detection of HBsAg in resource-poor settings. However, the available RDTs have inadequate sensitivity and therefore are not suitable for diagnosis of patients with low levels of HBsAg and for blood screening. To provide a high-sensitivity RDT, we developed a lateral flow immunoassay (LFIA) for HBsAg utilizing upconverting nanoparticle (UCNP) reporter. The UCNP-LFIA can use whole blood, serum, or plasma and the results can be read in 30 min using a reader device. When compared with a commercial conventional visually read LFIA, the developed UCNP-LFIA had a Limit of Detection (LoD) of 0.1 IU HBsAg/ml in spiked serum, whereas the LoD of the conventional LFIA was 3.2 IU HBsAg/ml. The developed UCNP-LFIA fulfills the WHO criterion for blood screening (LoD ≤ 0.13 IU HBsAg/ml) in terms of LoD. The UCNP-LFIA and conventional LFIA were evaluated with well-characterized sample panels. The UCNP-LFIA detected 20/24 HBsAg-positive samples within the HBsAg Performance Panel and 8/10 samples within the Mixed Titer Performance Panel, whereas the conventional LFIA detected 8/24 and 4/10 samples in these panels, respectively. The performance of the assays was further evaluated with HBsAg-positive (n = 108) and HBsAg-negative (n = 315) patient samples. In comparison with a central laboratory test, UCNP-LFIA showed 95.4% (95% CI: 89.5–98.5%) sensitivity whereas sensitivity of the conventional LFIA was 87.7% (95%CI: 79.9–93.3%).

6 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Iida MartiskainenIida Martiskainen
Iida Martiskainen
EJEtvi Juntunen
Etvi Juntunen
Teppo SalminenTeppo Salminen
Teppo Salminen
Karoliina VuorenpääKaroliina Vuorenpää
Karoliina Vuorenpää
Sherif BayoumySherif Bayoumy
Sherif Bayoumy
STSheikh Talha
Sheikh Talha
Rapid diagnostic tests (RDTs) are often used for the detection of anti-human immunodeficiency virus (HIV) antibodies in remote locations in low- and middle-income countries (LMIC) with low or limited access to central laboratories. The typical format of an RDT is a lateral flow assay (LFA) with visual interpretation prone to subjectivity. This risk of misinterpretation can be overcome with luminescent upconverting nanoparticle reporters (UCNPs) measured with a miniaturized easy-to-use reader instrument. An LFA with UCNPs for anti-HIV-1/2 antibodies was developed and the assay performance was evaluated extensively with challenging patient sample panels. Sensitivity (n = 145) of the UCNP-LFA was 96.6% (95% CI: 92.1–98.8%) and specificity (n = 309) was 98.7% (95% CI: 96.7–99.7%). Another set of samples (n = 200) was used for a comparison between the UCNP-LFA and a conventional visual RDT. In this comparison, the sensitivities for HIV-1 were 96.4% (95% CI: 89.8–99.3%) and 97.6% (95% CI: 91.6–99.7%), for the UCNP-LFA and conventional RDT, respectively. The specificity was 100% (95% CI: 96.4–100%) for both assays. The developed UCNP-LFA demonstrates the applicability of UCNPs for the detection of anti-HIV antibodies. The signal measurement is done by a reader instrument, which may facilitate automated result interpretation, archiving and transfer of data from de-centralized locations.