Jan Wildenhof

Dr. Jan Wildenhof

Private Clinic Schloss Schellenstein
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2020 in Medicina
Verified
Journal Article
Open access
PDF file
OBOliver Blume
Oliver Blume
ESEva Maria Schnödt
Eva Maria Schnödt
MBMichael Back
Michael Back
JWJan Wildenhof
Jan Wildenhof
FPFlorian A. Probst
Florian A. Probst
SOSven Otto
Sven Otto
Background and Objective: There is multifaceted evidence that variable-thread tapered implants (VTTIs) offer high primary stability but few regarding the long-term success. This retrospective clinical and radiological cohort study assessed the long-term outcome of VTTIs. Material and Methods: All patients treated in an OMFS practice with NobelActive Internal® VTTI between October 2007 and September 2011 were invited for clinical examination. The outcome variables were (i) survival rate, (ii) implant success according to the “Health Scale for Dental Implants” and (iii) prevalence of peri-implantitis. Furthermore, the effect of local and systemic risk factors was investigated. Results: In 81 subjects (46 females and 35 males, mean age 65.6 years) 270 implants (157 VTTIs and 113 others as a control group) were analyzed. In 7 out of 81 patients (8.6%), 8 out of 157 VTTIs (5.1%) and 5 out of 113 other implants (4.4%) were lost. Peri-implantitis, defined as (i) presence of bleeding on gentle probing (0.25 N) or exudation and (ii) radiographic bone loss exceeding 0.5 mm since implant insertion to last follow-up, was the most common reason for implant loss (11 out of 13, 84.6%). Sixty-six out of 87 VTTIs (75.9%) were successful. Seventeen out of 42 patients (40.5%) developed peri-implantitis on 29 out of 79 VTTI sites (36.7%). Plaque and missing keratinized peri-implant mucosa were identified as potential risk factors for the development of peri-implantitis. Conclusion: Variable-thread tapered implants showed good long-term results, even in low bone quality. Peri-implantitis was the most common reason for implant failure and may be connected to certain risk factors.

1 July 2021 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
OBOliver Blume
Oliver Blume
JWJan Wildenhof
Jan Wildenhof
SOSven Otto
Sven Otto
FPFlorian Probst
Florian Probst
Oliver Blume, MD, DDS/Jan Wildenhof, DDS/Sven Otto, MD, DDS/Florian A. Probst, MD, DDS: Purpose: The aim of this study was to investigate the influence of different clinical parameters on the primary stability of a variable thread tapered implant system with a focus on surgical undersizing protocols. Materials and Methods: This retrospective study evaluated patients who received NobelActive implants in a single institution. The relationship between the independent variables, bone quality, implant diameter, implant length, implantation time, region of the jaw, and surgical undersizing protocol, and the dependent variable, maximum insertion torque, was investigated. Statistical analysis was conducted using analysis of variance (ANOVA) and multiple linear regression. Results: A total of 1,292 implants placed in 574 fully or partially edentulous patients were evaluated. For the total sample size, without further differentiation between bone qualities, statistically significantly higher primary stability values were shown for an 8% to 9% undersized group (50.33 ± 17.16 Ncm), compared with a 16% undersized group (41.88 ± 17.63 Ncm), a 20% undersized group (33.65 ± 15.78 Ncm), a 26% to 28% undersized group (34.53 ± 15.49 Ncm), and a 35% to 44% undersized group (32.78 ± 18.80 Ncm). No statistical differences were found for undersizing protocols in bone quality 4. Bone quality had the highest influence on primary stability (Welch-Test F(3, 65.57) = 119.48, P < .001, η2 = .20). Contrary to the other investigated independent variables, no statistically significant differences in primary stability were found for the different implantation times. Conclusion: Undersizing protocols exceeding 8% to 9% do not seem to enhance primary stability values. Further studies are needed to investigate the biologic consequences of undersizing, including the impact of implant design characteristics.