Philipp Fürnstahl

Prof. Dr. Philipp Fürnstahl

Research in Orthopedic Computer Science, Balgrist University Hospital, University of Zurich, Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2019 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
FLFlorentin Liebmann
Florentin Liebmann
SRSimon Roner
Simon Roner
MAMarco von Atzigen
Marco von Atzigen
DSDavide Scaramuzza
Davide Scaramuzza
RSReto Sutter
Reto Sutter
Philipp FürnstahlPhilipp Fürnstahl
Philipp Fürnstahl

1 April 2020 in The Spine Journal
Verified
Journal Article
Closed access
FMFabio Müller
Fabio Müller
SRSimon Roner
Simon Roner
FLFlorentin Liebmann
Florentin Liebmann
JSJosé M. Spirig
José M. Spirig
Philipp FürnstahlPhilipp Fürnstahl
Philipp Fürnstahl
MFMazda Farshad
Mazda Farshad

1 December 2013 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
ASAndreas Schweizer
Andreas Schweizer
Philipp FürnstahlPhilipp Fürnstahl
Philipp Fürnstahl
LNLadislav Nagy
Ladislav Nagy

1 January 2020 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
PDF file
SFSandro F. Fucentese
Sandro F. Fucentese
PMPatrick Meier
Patrick Meier
LJLukas Jud
Lukas Jud
GKGian‐Luca Köchli
Gian‐Luca Köchli
AAAlexander Aichmair
Alexander Aichmair
Philipp FürnstahlPhilipp Fürnstahl
Philipp Fürnstahl
Purpose: High tibial osteotomy (HTO) is an effective treatment option in early osteoarthritis. However, preoperative planning and surgical execution can be challenging. Computer assisted three‐dimensional (3D) planning and patient‐specific instruments (PSI) might be helpful tools in achieving successful outcomes. Goal of this study was to assess the accuracy of HTO using PSI.Methods: All medial open wedge PSI‐HTO between 2014 and 2016 were reviewed. Using pre‐ and postoperative radiographs, hip‐knee‐ankle angle (HKA) and posterior tibial slope (PTS) were determined two‐dimensionally (2D) to calculate 2D accuracy. Using postoperative CT‐data, 3D surface models of the tibias were reconstructed and superimposed with the planning to calculate 3D accuracy.Results: Twenty‐three patients could be included. A mean correction of HKA of 9.7° ± 2.6° was planned. Postoperative assessment of HKA correction showed a mean correction of 8.9° ± 3.2°, resulting in a 2D accuracy for HKA correction of 0.8° ± 1.5°. The postoperative PTS changed by 1.7° ± 2.2°. 3D accuracy showed average 3D rotational differences of − 0.1° ± 2.3° in coronal plane, − 0.2° ± 2.3° in transversal plane, and 1.3° ± 2.1° in sagittal plane, whereby 3D translational differences were calculated as 0.1 mm ± 1.3 mm in coronal plane, − 0.1 ± 0.6 mm in transversal plane, and − 0.1 ± 0.6 mm in sagittal plane.Conclusion: The use of PSI in HTO results in accurate correction of mechanical leg axis. In contrast to the known problem of unintended PTS changes in conventional HTO, just slight changes of PTS could be observed using PSI. The use of PSI in HTO might be preferable to obtain desired correction of HKA and to maintain PTS.

14 May 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CDCyrill Dennler
Cyrill Dennler
LJLaurenz Jaberg
Laurenz Jaberg
JSJosé Spirig
José Spirig
CAChristoph Agten
Christoph Agten
TGTobias Götschi
Tobias Götschi
MFMazda Farshad
Mazda Farshad
Background: Precise insertion of pedicle screws is important to avoid injury to closely adjacent neurovascular structures. The standard method for the insertion of pedicle screws is based on anatomical landmarks (free-hand technique). Head-mounted augmented reality (AR) devices can be used to guide instrumentation and implant placement in spinal surgery. This study evaluates the feasibility and precision of AR technology to improve precision of pedicle screw insertion compared to the current standard technique. Methods: Two board-certified orthopedic surgeons specialized in spine surgery and two novice surgeons were each instructed to drill pilot holes for 40 pedicle screws in eighty lumbar vertebra sawbones models in an agar-based gel. One hundred and sixty pedicles were randomized into two groups: the standard free-hand technique (FH) and augmented reality technique (AR). A 3D model of the vertebral body was superimposed over the AR headset. Half of the pedicles were drilled using the FH method, and the other half using the AR method. Results: The average minimal distance of the drill axis to the pedicle wall (MAPW) was similar in both groups for expert surgeons (FH 4.8 ± 1.0 mm vs. AR 5.0 ± 1.4 mm, p = 0.389) but for novice surgeons (FH 3.4 mm ± 1.8 mm, AR 4.2 ± 1.8 mm, p = 0.044). Expert surgeons showed 0 primary drill pedicle perforations (PDPP) in both the FH and AR groups. Novices showed 3 (7.5%) PDPP in the FH group and one perforation (2.5%) in the AR group, respectively (p > 0.005). Experts showed no statistically significant difference in average secondary screw pedicle perforations (SSPP) between the AR and the FH set 6-, 7-, and 8-mm screws (p > 0.05). Novices showed significant differences of SSPP between most groups: 6-mm screws, 18 (45%) vs. 7 (17.5%), p = 0.006; 7-mm screws, 20 (50%) vs. 10 (25%), p = 0.013; and 8-mm screws, 22 (55%) vs. 15 (37.5%), p = 0.053, in the FH and AR group, respectively. In novices, the average optimal medio-lateral convergent angle (oMLCA) was 3.23° (STD 4.90) and 0.62° (STD 4.56) for the FH and AR set screws (p = 0.017), respectively. Novices drilled with a higher precision with respect to the cranio-caudal inclination angle (CCIA) category (p = 0.04) with AR. Conclusion: In this study, the additional anatomical information provided by the AR headset superimposed to real-world anatomy improved the precision of drilling pilot holes for pedicle screws in a laboratory setting and decreases the effect of surgeon’s experience. Further technical development and validations studies are currently being performed to investigate potential clinical benefits of the herein described AR-based navigation approach.

1 January 2016 in The Journal of Hand Surgery
Verified
Journal Article
Closed access
ASAndreas Schweizer
Andreas Schweizer
FMFlavien Mauler
Flavien Mauler
LVLazaros Vlachopoulos
Lazaros Vlachopoulos
LNLadislav Nagy
Ladislav Nagy
Philipp FürnstahlPhilipp Fürnstahl
Philipp Fürnstahl