The performance of nine different vapor barrier systems comprising polyethylene (PE) membranes were assessed. The vapor barrier systems comprised membranes of virgin PE, 100% new PE, regenerated PE and multilayered virgin and regenerated PE. Membranes were joined either with tape suited to the individual system or an adhesive base on butyl rubber. The vapor barrier systems were evaluated and compared using standard laboratory tests. Chemical analytical techniques and physicomechanical tests were used. Mechanical properties were assessed using laboratory tests recommended by the harmonized standard EN 1385. Chemical analyses followed standard laboratory protocols performed with specialized equipment and visual examination. Chemical and mechanical properties were determined before and after exposure to an aging regime comprising 168 days at 70 °C in total. The chemical stability of the plastic present in each membrane was further evaluated after an additional exposure to an aging regime comprising 50 days followed by another 30 days at 70 °C. Additional aging indicated chemical changes in the membrane material with time. However, it was not possible to distinguish between aging properties for membranes containing virgin PE, 100% new PE, regenerated PE or multilayered virgin and regenerated PE.
Naturally ventilated cold attics are traditional in many Danish single-family homes. The moisture balance of these attics is dependent on sufficient ventilation for removal of excess moisture. Moisture is generated in the dwelling below, and transported to attic spaces through convection and diffusion. Therefore, airtight ceilings are vital for reduction of excess moisture, which may yield mould growth in the attic. If mould spores migrate to the dwelling it can cause risk of health concerns for occupants. The presents study includes analysis of tracer gas and temperature/relative humidity measurements, in 30 dwellings/attics. The measurements yielded results of both air change rates in attics and dwellings, as well as air exchange between the two zones. Four of 30 houses, met the recommended air change rate of 0.5 h−1, and only in summer. The air change rate in the attics was found to be higher, and with larger variation compared to the dwelling. Visible mould growth was found in three attics, which all exhibited low air change rates. Air exchange between zones occurred in houses both with and without vapour barriers. The downward air exchange in summer, was however slightly larger in cases without vapour barriers. These results highlight the importance of airtight ceilings for both dwelling and attic performance.