Massively parallel sequencing (MPS) is on the advent of a broad scale application in forensic research and casework. The improved capabilities to analyse evidentiary traces representing unbalanced mixtures is often mentioned as one of the major advantages of this technique. However, most of the available software packages that analyse forensic short tandem repeat (STR) sequencing data are not well suited for high throughput analysis of such mixed traces. The largest challenge is the presence of stutter artefacts in STR amplifications, which are not readily discerned from minor contributions. FDSTools is an open-source software solution developed for this purpose. The level of stutter formation is influenced by various aspects of the sequence, such as the length of the longest uninterrupted stretch occurring in an STR. When MPS is used, STRs are evaluated as sequence variants that each have particular stutter characteristics which can be precisely determined. FDSTools uses a database of reference samples to determine stutter and other systemic PCR or sequencing artefacts for each individual allele. In addition, stutter models are created for each repeating element in order to predict stutter artefacts for alleles that are not included in the reference set. This information is subsequently used to recognise and compensate for the noise in a sequence profile. The result is a better representation of the true composition of a sample. Using Promega Powerseq™ Auto System data from 450 reference samples and 31 two-person mixtures, we show that the FDSTools correction module decreases stutter ratios above 20% to below 3%. Consequently, much lower levels of contributions in the mixed traces are detected. FDSTools contains modules to visualise the data in an interactive format allowing users to filter data with their own preferred thresholds.
1 May 2014 in Forensic Science International: Genetics
Regularly, STR results obtained with different PCR amplification kits are compared, for instance with old cases, when revisiting cold cases or when addressing cross-border crimes. It is known that differences in primer design for the same loci in different kits may give rise to null alleles or shifted alleles. In this study, the genotyping results of 2085 Dutch male samples were compared for six autosomal STR kits (Promega's PowerPlex(®) 16, ESX-16 and ESI-17 Systems, Qiagen's Investigator(®) ESSplex Kit and Applied Biosystems' AmpFlSTR(®) Identifiler and NGM PCR Amplification Kits). A total of 19 discordant autosomal genotyping results were obtained that were examined by sequence analysis using Roche-454 next generation sequencing and/or Sanger sequencing. A further 25 discordances were found and sequenced for the Amelogenin locus. The 24 samples showing the same primer binding site mutation at the Amelogenin locus were subjected to X-STR analysis in order to assess whether they could share a common origin, which appeared not to be the case. Based on the sequencing results, we set the final genotypes and determined the allele frequencies of 23 autosomal STRs for the Dutch reference database.
1 March 2016 in Forensic Science International: Genetics