Gediminas Mainelis

Prof. Gediminas Mainelis

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2019 in Aerosol Science and Technology
Verified
Journal Article
Closed access
GMGediminas Mainelis
Gediminas Mainelis
Bioaerosol sampling is an essential and integral part of any bioaerosol investigation. Since bioaerosols are very diverse in terms of their sizes, species, biological properties, and requirements for their detection and quantification, bioaerosol sampling is an active, yet challenging research area. This paper was inspired by the discussions during the 2018 International Aerosol Conference (IAC) (St. Louis, MO) regarding the need to summarize the current state of the art in bioaerosol research, including bioaerosol sampling, and the need to develop a more standardized set of guidelines for protocols used in bioaerosol research. The manuscript is a combination of literature review and perspectives: it discusses the main bioaerosol sampling techniques and then overviews the latest technical developments in each area; the overview is followed by the discussion of the emerging trends and developments in the field, including personal sampling, application of passive samplers, and advances toward improving bioaerosol detection limits as well as the emerging challenges such as collection of viruses and collection of unbiased samples for bioaerosol sequencing. The paper also discusses some of the practical aspects of bioaerosol sampling with particular focus on sampling aspects that could lead to bioaerosol determination bias. The manuscript concludes by suggesting several goals for bioaerosol sampling and development community to work towards and describes some of the grand bioaerosol challenges discussed at the IAC 2018.

24 May 2010 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
OGOlga B. Garbuzenko
Olga B. Garbuzenko
MSMaha Saad
Maha Saad
VPVitaly P. Pozharov
Vitaly P. Pozharov
KRKenneth R. Reuhl
Kenneth R. Reuhl
GMGediminas Mainelis
Gediminas Mainelis
TMTamara Minko
Tamara Minko
Development of cancer cell resistance, low accumulation of therapeutic drug in the lungs, and severe adverse treatment side effects represent main obstacles to efficient chemotherapy of lung cancer. To overcome these difficulties, we propose inhalation local delivery of anticancer drugs in combination with suppressors of pump and nonpump cellular resistance. To test this approach, nanoscale-based delivery systems containing doxorubicin as a cell death inducer, antisense oligonucleotides targeted to MRP1 mRNA as a suppressor of pump resistance and to BCL2 mRNA as a suppressor of nonpump resistance, were developed and examined on an orthotopic murine model of human lung carcinoma. The experimental results show high antitumor activity and low adverse side effects of proposed complex inhalatory treatment that cannot be achieved by individual components applied separately. The present work potentially contributes to the treatment of lung cancer by describing a unique combinatorial local inhalation delivery of drugs and suppressors of pump and nonpump cellular resistance.

1 August 2005 in Indoor Air
Verified
Journal Article
Closed access
PDF file
SGS. A. Grinshpun
S. A. Grinshpun
GMGediminas Mainelis
Gediminas Mainelis
MTM. Trunov
M. Trunov
AAAtin Adhikari
Atin Adhikari
TRT. Reponen
T. Reponen
KWK. Willeke
K. Willeke
Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from indoor air. In this study, five ionic air purifiers (two wearable and three stationary) that produce unipolar air ions were evaluated with respect to their ability to reduce aerosol exposure in confined indoor spaces. The concentration decay of respirable particles of different properties was monitored in real time inside the breathing zone of a human manikin, which was placed in a relatively small (2.6 m3) walk-in chamber during the operation of an ionic air purifier in calm air and under mixing air condition. The particle removal efficiency as a function of particle size was determined using the data collected with a size-selective optical particle counter. The removal efficiency of the more powerful of the two wearable ionic purifiers reached about 50% after 15 min and almost 100% after 1.5 h of continuous operation in the chamber under calm air conditions. In the absence of external ventilation, air mixing, especially vigorous one (900 CFM), enhanced the air cleaning effect. Similar results were obtained when the manikin was placed inside a partial enclosure that simulated an aircraft seating configuration. All three stationary ionic air purifiers tested in this study were found capable of reducing the aerosol concentration in a confined indoor space. The most powerful stationary unit demonstrated an extremely high particle removal efficiency that increased sharply to almost 90% within 5-6 min, reaching about 100% within 10-12 min for all particle sizes (0.3-3 microm) tested in the chamber. For the units of the same emission rate, the data suggest that the ion polarity per se (negative vs. positive) does not affect the performance but the ion emission rate does. The effects of particle size (within the tested range) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria) as well as the effects of the manikin's body temperature and its breathing on the ionic purifier performance were either small or insignificant. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when used inside confined spaces with a relatively high surface-to-volume ratio. Ionic air purifiers have become increasingly popular for removing dust particles, aeroallergens and airborne microorganisms from indoor air in various settings. While the indoor air cleaning effect, resulting from unipolar and bipolar ion emission, has been tested by several investigators, there are still controversial claims (favorable and unfavorable) about the performance of commercially available ionic air purifiers. Among the five tested ionic air purifiers (two wearable and three stationary) producing unipolar air ions, the units with a higher ion emission rate provided higher particle removal efficiency. The ion polarity (negative vs. positive), the particle size (0.3-3 microm) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria), as well as the body temperature and breathing did not considerable affected the ionization-driven particle removal. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when they are used inside confined spaces with a relatively high surface-to-volume ratio (such as automobile cabins, aircraft seating areas, bathrooms, cellular offices, small residential rooms, and animal confinements). Based on our experiments, we proposed that purifiers with a very high ion emission rate be operated in an intermittent mode if used indoors for extended time periods. As the particles migrate to and deposit on indoor surfaces during the operation of ionic air purifiers, some excessive surface contamination may occur, which introduces the need of periodic cleaning these surfaces.

1 February 1999 in Aerosol Science and Technology
Verified
Journal Article
Open access
GMGediminas Mainelis
Gediminas Mainelis
The applicability of electrostatic precipitation as a method for bioaerosol collection was investigated by using a modified Electrostatic Aerosol Sampler (EAS) (Model 3100, TSI Inc., St. Paul, MN). The physical and biological efficiencies of this method were determined. The tests were performed using three bacterial species which were collected onto agar, into water, and onto filters. The physical collection efficiency was higher than 80% when using a sampling flow rate of 1 L/min. When the Bacillus subtilis var niger (BG) spores were collected on agar, about 50-60% of the collected culturable organisms formed colonies. The bioefficiency exceeded 90% when the BG spores were collected on a filter, but was only 15-22% when collected into water. The Mycobacterium bovis BCG bacteria recovered at the 0-8% level on all three collection media. The least number of colonies were formed when Pseudomonas fluorescens bacteria were collected on any of the collection media. The data show that the process of electrostatic collection is very complex for sensitive airborne bacteria and thus several effects should be considered when assessing its bioefficiency. In separate tests conducted without aerosol flow through the sampler, bacteria placed onto the collection media did not show any significant reduction in bacterial recovery while exposed to a strong electric field. It was found that evaporation from the collection media, such as agar or water, increases the humidity inside the EAS and may affect the size distribution of the particles being collected, resulting in decreased physical and biological efficiencies of the electrostatic precipitation method. For hardy microorganisms such as BG spores, the bioefficiency for electrostatic collection is high, thus encouraging further explorations of the electrostatic method for sampling bioaerosols.

1 October 2002 in Journal of Aerosol Science
Verified
Journal Article
Closed access
GMGediminas Mainelis
Gediminas Mainelis
AAAtin Adhikari
Atin Adhikari
KWKlaus Willeke
Klaus Willeke
SLShu-An Lee
Shu-An Lee
TRTiina Reponen
Tiina Reponen
SGSergey A Grinshpun
Sergey A Grinshpun

1 September 2001 in Journal of Aerosol Science
Verified
Journal Article
Closed access
GMGediminas Mainelis
Gediminas Mainelis
KWKlaus Willeke
Klaus Willeke
PBPaul Baron
Paul Baron
TRTiina Reponen
Tiina Reponen
SGSergey A. Grinshpun
Sergey A. Grinshpun
STSaulius Trakumas
Saulius Trakumas