Sean Murphy

Dr. Sean Murphy

Wake Forest Institute for Regenerative Medicine, Wake Forest School of Medicine, 391 Technology Way, Winston-Salem, NC 27101, USA
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2019 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Sean MurphySean Murphy
Sean Murphy
PCPaolo De Coppi
Paolo De Coppi
AAAnthony Atala
Anthony Atala

12 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MAMohammed Albanna
Mohammed Albanna
KBKyle W. Binder
Kyle W. Binder
Sean MurphySean Murphy
Sean Murphy
JKJaehyun Kim
Jaehyun Kim
SQShadi A. Qasem
Shadi A. Qasem
JYJames J. Yoo
James J. Yoo
The early treatment and rapid closure of acute or chronic wounds is essential for normal healing and prevention of hypertrophic scarring. The use of split thickness autografts is often limited by the availability of a suitable area of healthy donor skin to harvest. Cellular and non-cellular biological skin-equivalents are commonly used as an alternative treatment option for these patients, however these treatments usually involve multiple surgical procedures and associated with high costs of production and repeated wound treatment. Here we describe a novel design and a proof-of-concept validation of a mobile skin bioprinting system that provides rapid on-site management of extensive wounds. Integrated imaging technology facilitated the precise delivery of either autologous or allogeneic dermal fibroblasts and epidermal keratinocytes directly into an injured area, replicating the layered skin structure. Excisional wounds bioprinted with layered autologous dermal fibroblasts and epidermal keratinocytes in a hydrogel carrier showed rapid wound closure, reduced contraction and accelerated re-epithelialization. These regenerated tissues had a dermal structure and composition similar to healthy skin, with extensive collagen deposition arranged in large, organized fibers, extensive mature vascular formation and proliferating keratinocytes.

26 February 2020 in Biofabrication
Verified
Journal Article
Closed access
Aleksander SkardalAleksander Skardal
Aleksander Skardal
JAJulio Aleman
Julio Aleman
Steven ForsytheSteven Forsythe
Steven Forsythe
SRShiny Rajan
Shiny Rajan
Sean MurphySean Murphy
Sean Murphy
AAAnthony Atala
Anthony Atala
Current practices in drug development have led to therapeutic compounds being approved for widespread use in humans, only to be later withdrawn due to unanticipated toxicity. These occurrences are largely the result of erroneous data generated by in vivo and in vitro preclinical models that do not accurately recapitulate human physiology. Herein, a human primary cell- and stem cell-derived 3D organoid technology is employed to screen a panel of drugs that were recalled from market by the FDA. The platform is comprised of multiple tissue organoid types that remain viable for at least 28 days, in vitro. For many of these compounds, the 3D organoid system was able to demonstrate toxicity. Furthermore, organoids exposed to non-toxic compounds remained viable at clinically relevant doses. Additional experiments were performed on integrated multi-organoid systems containing liver, cardiac, lung, vascular, testis, colon, and brain. These integrated systems proved to maintain viability and expressed functional biomarkers, long-term. Examples are provided that demonstrate how multi-organoid ‘body-on-a-chip’ systems may be used to model the interdependent metabolism and downstream effects of drugs across multiple tissues in a single platform. Such 3D in vitro systems represent a more physiologically relevant model for drug screening and will likely reduce the cost and failure rate associated with the approval of new drugs.

1 April 2020 in Acta Biomaterialia
Verified
Journal Article
Closed access
SRShiny Amala Priya Rajan
Shiny Amala Priya Rajan
JAJulio Aleman
Julio Aleman
MWMeiMei Wan
MeiMei Wan
NZNima Pourhabibi Zarandi
Nima Pourhabibi Zarandi
GNGoodwell Nzou
Goodwell Nzou
Aleksander SkardalAleksander Skardal
Aleksander Skardal

23 September 2017 in Stem Cells Translational Medicine
Verified
Journal Article
Open access
PDF file
Sean MurphySean Murphy
Sean Murphy
Aleksander SkardalAleksander Skardal
Aleksander Skardal
LSLujie Song
Lujie Song
KSKhiry Sutton
Khiry Sutton
RHRebecca Haug
Rebecca Haug
Anthony AtalaAnthony Atala
Anthony Atala
The early and effective treatment of wounds is vital to ensure proper wound closure and healing with appropriate functional and cosmetic outcomes. The use of human amnion membranes for wound care has been shown to be safe and effective. However, the difficulty in handling and placing thin sheets of membrane, and the high costs associated with the use of living cellularized tissue has limited the clinical application of amniotic membrane wound healing products. Here, we describe a novel amnion membrane-derived product, processed to result in a cell-free solution, while maintaining high concentrations of cell-derived cytokines and growth factors. The solubilized amnion membrane (SAM) combined with the carrier hyaluronic acid (HA) hydrogel (HA-SAM) is easy to produce, store, and apply to wounds. We demonstrated the efficacy of HA-SAM as a wound treatment using a full-thickness murine wound model. HA-SAM significantly accelerated wound closure through re-epithelialization and prevented wound contraction. HA-SAM-treated wounds had thicker regenerated skin, increased total number of blood vessels, and greater numbers of proliferating keratinocytes within the epidermis. Overall, this study confirms the efficacy of the amnion membrane as a wound treatment/dressing, and overcomes many of the limitations associated with using fresh, cryopreserved, or dehydrated tissue by providing a hydrogel delivery system for SAM. Stem Cells Translational Medicine 2017;6:2020–2032

22 June 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TLTimothy Leach
Timothy Leach
UGUma Gandhi
Uma Gandhi
KRKimberly D. Reeves
Kimberly D. Reeves
KSKristina Stumpf
Kristina Stumpf
KOKenichi Okuda
Kenichi Okuda
Sean MurphySean Murphy
Sean Murphy
The human airways are complex structures with important interactions between cells, extracellular matrix (ECM) proteins and the biomechanical microenvironment. A robust, well-differentiated in vitro culture system that accurately models these interactions would provide a useful tool for studying normal and pathological airway biology. Here, we report the development and characterization of a physiologically relevant air–liquid interface (ALI) 3D airway ‘organ tissue equivalent’ (OTE) model with three novel features: native pulmonary fibroblasts, solubilized lung ECM, and hydrogel substrate with tunable stiffness and porosity. We demonstrate the versatility of the OTE model by evaluating the impact of these features on human bronchial epithelial (HBE) cell phenotype. Variations of this model were analyzed during 28 days of ALI culture by evaluating epithelial confluence, trans-epithelial electrical resistance, and epithelial phenotype via multispectral immuno-histochemistry and next-generation sequencing. Cultures that included both solubilized lung ECM and native pulmonary fibroblasts within the hydrogel substrate formed well-differentiated ALI cultures that maintained a barrier function and expressed mature epithelial markers relating to goblet, club, and ciliated cells. Modulation of hydrogel stiffness did not negatively impact HBE differentiation and could be a valuable variable to alter epithelial phenotype. This study highlights the feasibility and versatility of a 3D airway OTE model to model the multiple components of the human airway 3D microenvironment.