Fatih Șen

Prof. Dr. Fatih Șen

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2014 in Nature Materials
Verified
Journal Article
Closed access
JGJuan Pablo Giraldo
Juan Pablo Giraldo
MLMarkita Landry
Markita Landry
SFSean M. Faltermeier
Sean M. Faltermeier
TMThomas P. McNicholas
Thomas P. McNicholas
NINicole Iverson
Nicole Iverson
MSMichael S. Strano
Michael S. Strano

3 November 2013 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
NINicole Iverson
Nicole Iverson
PBPaul W. Barone
Paul W. Barone
MSMia Shandell
Mia Shandell
LTLaura J. Trudel
Laura J. Trudel
SSSelda Sen
Selda Sen
MSMichael S. Strano
Michael S. Strano
Single-walled carbon nanotubes are particularly attractive for biomedical applications, because they exhibit a fluorescent signal in a spectral region where there is minimal interference from biological media. Although single-walled carbon nanotubes have been used as highly sensitive detectors for various compounds, their use as in vivo biomarkers requires the simultaneous optimization of various parameters, including biocompatibility, molecular recognition, high fluorescence quantum efficiency and signal transduction. Here we show that a polyethylene glycol ligated copolymer stabilizes near-infrared-fluorescent single-walled carbon nanotubes sensors in solution, enabling intravenous injection into mice and the selective detection of local nitric oxide concentration with a detection limit of 1 µM. The half-life for liver retention is 4 h, with sensors clearing the lungs within 2 h after injection, thus avoiding a dominant route of in vivo nanotoxicology. After localization within the liver, it is possible to follow the transient inflammation using nitric oxide as a marker and signalling molecule. To this end, we also report a spatial-spectral imaging algorithm to deconvolute fluorescence intensity and spatial information from measurements. Finally, we demonstrate that alginate-encapsulated single-walled carbon nanotubes can function as implantable inflammation sensors for nitric oxide detection, with no intrinsic immune reactivity or other adverse response for more than 400 days.

24 November 2013 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
JZJingqing Zhang
Jingqing Zhang
MLMarkita Landry
Markita Landry
PBPaul W. Barone
Paul W. Barone
JKJong-Ho Kim
Jong-Ho Kim
SLShangchao Lin
Shangchao Lin
MSMichael S. Strano
Michael S. Strano

1 August 2020 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
Hassan Karimi-malehHassan Karimi-maleh
Hassan Karimi-maleh
KCKemal Cellat
Kemal Cellat
KAKubilay Arıkan
Kubilay Arıkan
ASAysun Savk
Aysun Savk
FKFatemeh Karimi
Fatemeh Karimi
FȘFatih Șen
Fatih Șen

16 July 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Hassan Karimi-malehHassan Karimi-maleh
Hassan Karimi-maleh
FKFatemeh Karimi
Fatemeh Karimi
Yasin OroojiYasin Orooji
Yasin Orooji
GMGhobad Mansouri
Ghobad Mansouri
ARAmir Razmjou
Amir Razmjou
FȘFatih Șen
Fatih Șen
A highly sensitive electrocatalytic sensor was designed and fabricated by the incorporation of NiO dope Pt nanostructure hybrid (NiO–Pt–H) as conductive mediator, bis (1,10 phenanthroline) (1,10-phenanthroline-5,6-dione) nickel(II) hexafluorophosphate (B,1,10,P,1,10, PDNiPF6), and electrocatalyst into carbon paste electrode (CPE) matrix for the determination of cysteamine. The NiO–Pt–H was synthesized by one-pot synthesis strategy and characterized by XRD, elemental mapping analysis (MAP), and FESEM methods. The characterization data, which confirmed good purity and spherical shape with a diameter of ⁓ 30.64 nm for the synthesized NiO–Pt–H. NiO–Pt–H/B,1,10, P,1,10, PDNiPF6/CPE, showed an excellent catalytic activity and was used as a powerful tool for the determination of cysteamine in the presence of serotonin. The NiO–Pt–H/B,1,10, P,1,10, PDNiPF6/CPE was able to solve the overlap problem of the two drug signals and was used for the determination of cysteamine and serotonin in concentration ranges of 0.003–200 µM and 0.5–260 µM with detection limits of 0.5 nM and 0.1 µM, using square wave voltammetric method, respectively. The NiO–Pt–H/B,1,10,P,1,10,PDNiPF6/CPE showed a high-performance ability for the determination of cysteamine and serotonin in the drug and pharmaceutical serum samples with the recovery data of 98.1–103.06%.

28 March 2007 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
FȘFatih Șen
Fatih Șen
GGGülsün Gökaǧaç
Gülsün Gökaǧaç