Application of a discrete time (DT) sliding mode controller (SMC) in the control structure of the primary controller of a three-phase LCL grid inverter is presented. The design of the inverter side current control loop is performed using a DT linear model of the grid inverter with LCL filter at output terminals. The DT quasi-sliding mode control was used due to its robustness to external and parametric disturbances. Additionally, in order to improve disturbance compensation, a disturbance compensator is also implemented. Also, a specific anti-windup mechanism has been implemented in the structure of the controller to prevent large overshoots in the inverter response in case of random disturbances of grid voltages, or sudden changes in the commanded power. The control of the grid inverter is realized in the reference system synchronized with the voltage of the power grid. The development of the digitally realized control subsystem is presented in detail, starting from theoretical considerations, through computer simulations to experimental tests. The experimental results confirm good static and dynamic performance.
A method for digital direct power control design for grid‐connected energy conversion systems was proposed in this paper. The active and reactive powers are directly controlled with constant switching frequency by selecting an appropriate switching control sequence of voltage source converter as a key part of energy conversion systems. The control design combines a discrete‐time sliding mode control and predictive control. The selection of feasible switching control vectors is a direct result of the discrete‐time sliding mode control approach. These vectors satisfy the existence conditions of the sliding mode, but each of them induces system motion with different properties. The task of predictive control is to select an appropriate switching control sequence to reduce the chattering phenomenon, steady‐state error, and overshoot. The cost function of the prediction process is defined as the average value of both power errors on the prediction horizon of three sampling periods. Simulation results, experimental results, and results of a comparative analysis are presented in order to show the performance and effectiveness of the proposed control design.