Shabnam Siddiqui

Dr. Shabnam Siddiqui

Department of Chemistry and Physics, Louisiana State University Shreveport, Shreveport, LA, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
SBSanjeev Billa
Sanjeev Billa
YYYaswanthi Yanamadala
Yaswanthi Yanamadala
IHImran Hossain
Imran Hossain
SSShabnam Siddiqui
Shabnam Siddiqui
NMNicolaie Moldovan
Nicolaie Moldovan
PAPrabhu Arumugam
Prabhu Arumugam
Imbalances in levels of glutamate (GLU) and gamma-aminobutyric acid (GABA) and their sub-second signaling dynamics occur in several brain disorders including traumatic brain injury, epilepsy, and Alzheimer’s disease. The present work reports on the optimization and in vivo testing of a silicon (Si) multifunctional biosensor probe for sub-second simultaneous real-time detection of GLU and GABA. The Si probe features four surface-functionalized platinum ultramicroelectrodes (UMEs) for detection of GLU and GABA, a sentinel site, and integrated microfluidics for in-situ calibration. Optimal enzyme concentrations, size-exclusion phenylenediamine layer and micro spotting conditions were systematically investigated. The measured GLU sensitivity for the GLU and GABA sites were as high as 219 ± 8 nA μM−1 cm−2 (n = 3). The measured GABA sensitivity was as high as 10 ± 1 nA μM−1 cm−2 (n = 3). Baseline recordings (n = 18) in live rats demonstrated a useful probe life of at least 11 days with GLU and GABA concentrations changing at the levels of 100′s and 1000′s of μM and with expected periodic bursts or fluctuations during walking, teeth grinding and other activities and with a clear difference in the peak amplitude of the sensor fluctuations between rest (low) and activity (higher), or when the rat was surprised (a reaction with no movement). Importantly, the probe could improve methods for large-scale monitoring of neurochemical activity and network function in disease and injury, in live rodent brain.

6 May 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
ACAn-Yi Chang
An-Yi Chang
SSShabnam Siddiqui
Shabnam Siddiqui
PAPrabhu Arumugam
Prabhu Arumugam
Neurochemicals play a critical role in the function of the human brain in healthy and diseased states. Here, we have investigated three types of microelectrodes, namely boron-doped ultrananocrystalline diamond (BDUNCD), nafion-modified BDUNCD, and nafion–multi-walled carbon nanotube (MWCNT)-modified BDUNCD microelectrodes for long-term neurochemical detection. A ~50 nm-thick nafion–200-nm-thick MWCNT-modified BDUNCD microelectrode provided an excellent combination of sensitivity and selectivity for the detection of dopamine (DA; 6.75 μA μM−1 cm−2) and serotonin (5-HT; 4.55 μA μM−1 cm−2) in the presence of excess amounts of ascorbic acid (AA), the most common interferent. Surface stability studies employing droplet-based microfluidics demonstrate rapid response time (<2 s) and low limits of detection (5.4 ± 0.40 nM). Furthermore, we observed distinguishable DA and 5-HT current peaks in a ternary mixture during long-term stability studies (up to 9 h) with nafion–MWCNT-modified BDUNCD microelectrodes. Reduced fouling on the modified BDUNCD microelectrode surface offers significant advantages for their use in long-term neurochemical detection as compared to those of prior-art microelectrodes.

23 August 2022 in Education Sciences
Verified
Journal Article
Open access
PDF file
SSShabnam Siddiqui
Shabnam Siddiqui
An efficacious assessment tool is as necessary for improving physics education as are innovative and effective methods of teaching physics. Most tests focus on evaluating students knowledge in specific areas such as conceptual understating, quantitative, and analytical problem-solving skills. Testing students’ critical thinking has remained a difficult task. Further, testing students comprehensive knowledge is even more challenging. We present here a new assessment tool with the acronym “Categorized and Correlated Multiple Choice Questions” (CCMCQs) for evaluating the comprehensive physics knowledge level of students. This tool consists of correlated questions posed in three different sub-categories of physics. Those sub-categories are: (i) Conceptual understanding, (ii) Critical thinking, and (iii) Quantitative understanding. The questions are structured to first pose a conceptual question which is then correlated with a critical thinking question and that critical thinking question is further correlated with a quantitative question. Thus, all three questions are correlated with each other, and such correlated questions aid the student and teacher alike to identify learning deficiency more accurately, and guide students to self-correct their knowledge of physics by providing appropriate direction. Further, we discuss the outcomes of a one semester study on CCMCQs using data obtained from an introductory physics course.

1 March 2022 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
CTChao Tan
Chao Tan
HYHaocheng Yin
Haocheng Yin
VBVictoria Brooks
Victoria Brooks
PAPrabhu Arumugam
Prabhu Arumugam
SSShabnam Siddiqui
Shabnam Siddiqui
A systematic study of electrochemically roughened (ECR) thin film platinum (Pt) microelectrodes for glutamate, GLU (a major excitatory neurotransmitter) detection is presented. Scanning electron microscopy, energy dispersive spectroscopy, surface profilometry, electrochemical impedance spectroscopy and amperometry techniques were applied to investigate the effect of high-frequency electrical pulses on Pt microelectrode roughness, electroactive area, charge transfer resistance, and sensitivity and selectivity to hydrogen peroxide, a by-product of enzymatic biosensors and GLU. An increase in the mean surface roughness from 9.0 ± 0.5 to 116.3 ± 7.4 nm (n = 3) was observed which resulted in a 55 ± 2% (n = 3) increase in the electroactive area. An ECR microelectrode treated at +1.4 V and coated with a selective coating produced a GLU selectivity value of 342 ± 34 (n = 3) vs ascorbic acid and the highest GLU sensitivity of 642 ± 45 nAμM−1cm−2 (n = 3) when compared to other surface-treated Pt microelectrodes reported in the literature. An impedance model was created to elucidate the microstructural and electrochemical property changes to the ECR microelectrodes. The ECR surface comprises of uniformly distributed homogenous pores with very low impedance, which is ∼6-times lower when compared to a methanol cleaned electrode. The model could lay a foundation for the rational designing of biosensors for enhanced neurotransmitter detection.

24 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
HYHaocheng Yin
Haocheng Yin
CTCHAO TAN
CHAO TAN
SSShabnam Siddiqui
Shabnam Siddiqui
PAPrabhu Arumugam
Prabhu Arumugam
We report the microfabrication and characterization of concentric gold nanoring electrodes (Au NREs), which were fabricated by patterning two gold nanoelectrodes on the same silicon (Si) micropillar tip. Au NREs of 165 ± 10 nm in width were micropatterned on a 6.5 ± 0.2 µm diameter 80 ± 0.5 µm height Si micropillar with an intervening ~ 100 nm thick hafnium oxide insulating layer between the two nanoelectrodes. Excellent cylindricality of the micropillar with vertical sidewalls as well as a completely intact layer of a concentric Au NRE including the entire micropillar perimeter has been achieved as observed via scanning electron microscopy and energy dispersive spectroscopy data. The electrochemical behavior of the Au NREs was characterized by steady-state cyclic voltammetry and electrochemical impedance spectroscopy. The applicability of Au NREs to electrochemical sensing was demonstrated by redox cycling with the ferro/ferricyanide redox couple. The redox cycling amplified the currents by 1.63-fold with a collection efficiency of > 90% on a single collection cycle. The proposed micro-nanofabrication approach with further optimization studies shows great promise for the creation and expansion of concentric 3D NRE arrays with controllable width and nanometer spacing for electroanalytical research and applications such as single-cell analysis and advanced biological and neurochemical sensing.