Fire spread occurs via radiation, flame contact, and firebrands. While firebrand showers are known to be a cause of spot fires which ignite fuels far from the main fire front, in the case of short distance spot fires, radiation from the main fire may play a role for firebrand induced ignition processes. Many past investigations have focused on singular effects on fire spread, and little is known about coupled effects. The coupled effect of radiative heat flux and firebrand showers on ignition processes of fuel beds is studied by using a newly developed experimental protocol. The newly developed protocol includes the addition of a radiant panel to the existing experimental setup of a firebrand generator coupled to a wind facility. Experiments were performed under an applied wind field, as the wind is a key parameter in large outdoor fire spread processes. Results show that radiant heat flux plays an important role for ignition by firebrands under 6 m/s while little effect was observed under 8 m/s.
Wildland fires and wildland urban-interface (WUI) fires have become a significant problem in recent years. The mechanisms of home ignition in WUI fires are direct flame contact, thermal radiation, and firebrand attack. Out of these three fire spread factors, firebrands are considered to be a main driving force for rapid fire spread as firebrands can fly far from the fire front and ignite structures. The limited experimental data on firebrand showers limits the ability to design the next generation of communities to resist WUI fires to these types of exposures. The objective of this paper is to summarize, compare, and reconsider the results from previous experiments, to provide new data and insights to prevent home losses from firebrands in WUI fires. Comparison of different combustible materials around homes revealed that wood decking assemblies may be ignited within similar time to mulch under certain conditions.