Wenli Quan

Mr. Wenli Quan

School of Civil Engineering, Xi’an University of Architecture & Technology

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2023 in Construction and Building Materials
Verified
Journal Article
Closed access
WQWenli Quan
Wenli Quan
WHWei Huang
Wei Huang
YAYongjiannan An
Yongjiannan An
XMXinwei Miao
Xinwei Miao
ZCZhuo Chen
Zhuo Chen

18 October 2023 in Construction and Building Materials
Verified
Journal Article
Closed access
WHWei Huang
Wei Huang
WQWenli Quan
Wenli Quan
XBXianzhong Bu
Xianzhong Bu
JWJian Wei
Jian Wei
RHRongrong Hu
Rongrong Hu
XMXinwei Miao
Xinwei Miao

26 July 2024 in Construction and Building Materials
Verified
Journal Article
Closed access
WQWenli Quan
Wenli Quan
WHWei Huang
Wei Huang
ZLZhijian Li
Zhijian Li
WMWenzhen Mao
Wenzhen Mao
XMXinwei Miao
Xinwei Miao
LHLijun Hao
Lijun Hao

4 May 2021 in Journal of Asian Architecture and Building Engineering
Verified
Journal Article
Open access
WHWei Huang
Wei Huang
WQWenli Quan
Wenli Quan
PGPei Ge
Pei Ge
An orthogonal test method was used to do sensibility analysis on the compressive strength and splitting strength of hybrid fiber-reinforced recycled aggregate concrete (HyFRAC). And a prediction model of compressive strength of HyFRAC based on Convolutional Neural Network (CNN) was proposed. The results show the ratio of recycled brick aggregate (RBA) to recycled concrete aggregate (RCA) has been proved the greatest influence on the compressive strength and splitting tensile strength of HyFRAC, followed by the water reducing agent content, finally the ratio of glass fiber (GF) to polypropylene fiber (PF). When RBA/RCA = 2/8, GF/PF = 7/3, and water reducing agent content is 0%, the compressive strength and splitting tensile strength of HyFRAC are the highest. According to JGJ/T10-2011, when RBA/RCA ≤ 6/4 and water reducing agent content ≥ 0.4%, the HyFRAC slump meets the 50m pumping height requirement; when RBA/RCA ≤ 4/6 and water reducing agent content ≥ 0.6%, the HyFRAC slump meets the 100m pumping height requirement. Compared to back propagation (BP) neural network model and multiple linear regression model, CNN model is more efficient in estimating the compressive strength of HyFRAC. The average relative errors and max relative errors of CNN model are 1.98% and 4.12%, respectively.

5 July 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
WQWenli Quan
Wenli Quan
WHWei Huang
Wei Huang
WMWenzhen Mao
Wenzhen Mao
XYXiuyuan Yu
Xiuyuan Yu
XZXinglei Zhou
Xinglei Zhou
LHLina Hou
Lina Hou

27 May 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
WHWei Huang
Wei Huang
WQWenli Quan
Wenli Quan
XMXinwei Miao
Xinwei Miao
YAYongjiannan An
Yongjiannan An
WSWenbo Sun
Wenbo Sun