Leonardo Iannucci

Dr. Leonardo Iannucci

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2021 in Macromolecular Materials and Engineering
Verified
Journal Article
Open access
PDF file
Camilla Noe´Camilla Noe´
Camilla Noe´
LILeonardo Iannucci
Leonardo Iannucci
SMSamuel Malburet
Samuel Malburet
AGAlain Graillot
Alain Graillot
Marco SangermanoMarco Sangermano
Marco Sangermano
SGSabrina Grassini
Sabrina Grassini
Bio‐based epoxy resins are attracting widespread interest in the field of polymer thermosets as environmentally friendly building block. In the present study, the feasibility of applying UV‐curable epoxidized vegetable oils (EVOs) as anti‐corrosion coating is investigated. Rheological characterization of EVOs is carried out, and their viscosity‐shear relationship is evaluated. The cationic UV‐curing of EVOs successfully gives rise to crosslinked materials with a wide range of thermo‐mechanical properties, evaluated by differential scanning calorimetric analysis and dynamic thermal mechanical analysis. A high epoxy‐group conversion, ranging from 93% to 99%, is always obtained. The thermal stability and surface properties of the bio‐based coatings, such as, pencil hardness, adhesion, solvent resistance, and contact angle, are analyzed. Moreover, the corrosion protection effectiveness of the coatings is characterized by potentiodynamic polarization and electrochemical impedance spectroscopy measurements. In addition, field emission scanning electron microscopy is used to assess the samples morphology after corrosion tests.

1 March 2018 in Measurement
Verified
Journal Article
Closed access
SCS. Corbellini
S. Corbellini
EFE. Di Francia
E. Di Francia
SGS. Grassini
S. Grassini
LILeonardo Iannucci
Leonardo Iannucci
LLL. Lombardo
L. Lombardo
MPM. Parvis
M. Parvis

1 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Leila Es SebarLeila Es Sebar
Leila Es Sebar
LILeonardo Iannucci
Leonardo Iannucci
Emma AngeliniEmma Angelini
Emma Angelini
Sabrina GrassiniSabrina Grassini
Sabrina Grassini
MPMarco Parvis
Marco Parvis
This paper describes a portable low-cost device for performing Electrochemical Impedance Spectroscopy (EIS) measurements which is based on an off-the-shelf TeensyDuino. The instrument does not make use of other components like operational amplifiers so it can be readily set up by anyone having a Teensy device and some resistors. Teensy 3.2, 3.5 and 3.6 can be used to realize the EIS system. The instrument can measure the impedance in the frequency range from 0.01 Hz to 50000 Hz and by selecting the shunt resistor it can be adapted to different impedance values. No special instrumentation is required for the system calibration. The proposed system uncertainty is of less than 5% for an impedance of up to 50 Ωk, a value which is lower than the usual intrinsic uncertainty of most of corrosion experiments.

1 September 2019 in Journal of Materials Processing Technology
Verified
Journal Article
Closed access
Emilio BassiniEmilio Bassini
Emilio Bassini
LILeonardo Iannucci
Leonardo Iannucci
Mariangela LombardiMariangela Lombardi
Mariangela Lombardi
SBS. Biamino
S. Biamino
DUD. Ugues
D. Ugues
BPB. Picqué
B. Picqué

1 May 2017
Verified
Conference Paper
Closed access
MPMarco Parvis
Marco Parvis
SCSimone Corbellini
Simone Corbellini
LLLuca Lombardo
Luca Lombardo
LILeonardo Iannucci
Leonardo Iannucci
SGSabrina Grassini
Sabrina Grassini
Emma AngeliniEmma Angelini
Emma Angelini
The occurrence of light spinal diseases due to the low physical activity of daily life is continuously increasing. Recovering form these diseases requires specific and directed physical activity and can conveniently performed in swimming pools where the apparent weight reduction due to the water helps letting patients perform the relief movements. Unfortunately a way for easily assessing the correctness of the patient's movement is still missing and in most cases everything relies on the capabilities of the trainers, which must be continuously present. This paper describes an attempt to arrange a simple system suitable for a quasi on-line self assessing to the movement correctness. The proposed system is based on two inertial assemblies to be worn on the wrists and capable of sending data to a receiver installed at pool border. Data received from these small assemblies are processed to show the patients the symmetry of their movements, which is connected to the movement efficiency. The inertial assemblies are arranged by using a commercial miniaturized Inertial Measurement Unit, a Teensyduino board, and a μPanel WiFi transmitter which is able to send the data to the received during the swimming. The receiver process the data in-line so that, when the patients stop swimming to take a rest, they can be displayed to the patients as a self-assess of the just performed activity.

16 January 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LILeonardo Iannucci
Leonardo Iannucci
MPMarco Parvis
Marco Parvis
EFElisabetta Di Francia
Elisabetta Di Francia
SGSabrina Grassini
Sabrina Grassini
Developing longtime laboratory experiments is a challenging problem, which requires users to frequently get to the laboratories. “iHomeX” tries to tackle this problem by opening real laboratories to remote access: people working on the experiments are required to go to the laboratory and physically arrange their setups, but later on they can manage the experiment from home. The proposed solution can be used in many environments, but is especially useful in the case of long time tests, such as experiments related to electronic component failures, material fatigue, and corrosion. “iHomeX” lets researchers to remotely change the experimental parameters, while observing the effects of each action not only on signal levels, but also by following the experiment by means of a webcam. “iHomeX” remote laboratory has been employed and validated by the students of the M.Sc. course in corrosion science proving to be a useful and low cost solution.