Hamed Biglari

Dr. Hamed Biglari


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
MMMajid Mirzabeygi
Majid Mirzabeygi
MNMozhgan Naji
Mozhgan Naji
NYNader Yousefi
Nader Yousefi
MSMahmoud Shams
Mahmoud Shams
HBHamed Biglari
Hamed Biglari
AMAmirhossein Mahvi
Amirhossein Mahvi
Corrosion and scaling tendency of water is an etiology of economic and health concerns in the water supply systems. The aim of this study was to investigate the water stability in Torbat Heydariye drinking water distribution system. This cross-sectional study was done with cluster sampling schemes and 90 samples were collected by simple random sampling from 15 clusters. All samples were taken from water distribution network during 2014. Also, the water stability was determined using Langelier saturation index (LSI), Ryznar Stability index (RSI), Puckorius scaling index (PSI), Larson-Skold index (LS), and Aggressiveness index (AI). Physical and chemical analysis showed that the mean of pH, total dissolve solid, electrical conductivity, chloride concentration, sulfate, temperature, bicarbonate, total alkalinity, calcium hardness were 7.75, 896 mg/L, 1,254 μMoh/cm, 203 mg/L, 201 mg/L, 22.7°C, 251 mg/L, 209 mg/L as CaCO3, 111.6 mg/L as CaCO3, respectively. The results illustrated that the average values of LSI, RSI, PSI, LS, and AI was 0.02 (±0.125), 7.71 (±0.2), 12.04 (±0.125), 7.55 (±0.3), and 1.7 (±0.456), respectively. Moreover, According to LSI, RSI, PSI, LS, and AI, corrosion tendency in the water network was 40, 100, 93.3, 94, and 33.3%, respectively. The severity of corrosion in different regions of Torbat Heydariye was displayed using Geographic Information System.

8 December 2016 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
HBHamed Biglari
Hamed Biglari
MAMojtaba Afsharnia
Mojtaba Afsharnia
VAVali Alipour
Vali Alipour
RKRasoul Khosravi
Rasoul Khosravi
KSKiomars Sharafi
Kiomars Sharafi
AMAmirhossein Mahvi
Amirhossein Mahvi

14 August 2017 in Toxin Reviews
Verified
Journal Article
Closed access
MMMohammad javad Mohammadi
Mohammad javad Mohammadi
AYAhmad Yari
Ahmad Yari
MSMojgan Saghazadeh
Mojgan Saghazadeh
SASoheil Sobhan Ardakani
Soheil Sobhan Ardakani
SGSahar Geravandi
Sahar Geravandi
YKYusef Omidi Khaniabadi
Yusef Omidi Khaniabadi
Based on research findings around the globe, the content of heavy metals (HM) has been kept limited in traditional popular pastries. This study was carried out to conduct a health risk assessment of heavy metals (As, Cd, Cu, Ni, Pb, Sn, and Zn) in Qom's Sohan (a kind of traditional Persian saffron brittle toffee) in 2015. Samples were selected randomly from the most popular brands of Sohan workshops in Qom. After the dry digestion of all Sohan samples, 100 different brands were analyzed via inductively coupled plasma atomic emission spectroscopy (ICP-AES). In this study, about 100 brands of Sohan made by vegetable oil or buttery were analyzed. The results showed that the metals level (µg/kg) in specimens for As, Cd, Cu, Ni, Pb, Sn, and Zn ranged 100–300, 10–50, 500–36,000, 60–550, 30–1750, 45–1700, and 2500–15000, respectively. In addition, health risk assessment showed that consuming the sample Sohan of the study poses no potential risks for children and adults. Results also revealed that although honey consumption has no adverse effect on the local population, concerning the increased pollutants’ entry, especially heavy metals, to the natural environment, it is very important to assess the foodstuffs before releasing them into the consumer market. According to the results of the study, an increase in the exposure level of heavy metal could potentially cause different health problems.

31 March 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
HBHamed Biglari
Hamed Biglari
ACAfsaneh Chavoshani
Afsaneh Chavoshani
NJNasibeh Javan
Nasibeh Javan
AMAmirhossein Mahvi
Amirhossein Mahvi
The quality of groundwater at any point below the surface shows the combined effects of many processes in the groundwater flow path. Factors of chemical reactions such as precipitation, weathering, dissolution, ion exchange, and various biological processes commonly happen below the surface, influencing fluoride concentrations in groundwater. Due to the fluoride effects on human health and the fact that few studies have been conducted on the factors affecting low fluoride amounts, these factors were investigated in Sistan and Baluchestan province, Iran. Water samples from 270 open dug wells, located in nine cities, were collected within 10 years (from 2004 to 2014). They were analyzed for major ions according to the standard methods. In this study, parameters such as pH, specific electrical conductivity, temperature, total dissolved solids, sulfate, nitrate, fluoride, total alkalinity, total hardness, carbonate, bicarbonate, magnesium, calcium, sodium, and potassium were analyzed. It was revealed that the soil was saline with natural pH. The fluoride amount in groundwater was deeply influenced by the composite of granitic, NaF, and CaF2 rocks for a prolonged period. The wells showed many changes of fluoride concentration from 0.125 to 1.71 mg/l and fluoride decreased toward the Southeast. Na+, Ca+, Cl−, and along with F showed a positive correlation; however, plots in comparison with F showed a negative correlation. Obtained results from this study indicate that the hydrological condition of groundwater is also an important factor controlling the amount of fluoride in groundwater.

12 April 2017 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
MKMostafa Karimaei
Mostafa Karimaei
KSKiomars Sharafi
Kiomars Sharafi
MMMasoud Moradi
Masoud Moradi
HGHamid Reza Ghaffari
Hamid Reza Ghaffari
HBHamed Biglari
Hamed Biglari
NFNazir Fattahi
Nazir Fattahi
Continuous sample drop flow microextraction (CSDFME) combined with gas chromatography-electron-capture detection (GC-ECD) has been developed as a high preconcentration technique for the determination of chlorophenols (CPs) in environmental water samples. In this method, a few microliters of organic solvent (11.0 μL chlorobenzene) is transferred to the bottom of a conical test tube. Then 10.0 mL of aqueous solution transforms into fine droplets while passing through the organic solvent. At this stage, CPs are extracted into the organic solvent. Under the optimum conditions, enrichment factors and extraction recoveries are in the range of 630–1770 and 31.5–88.5, respectively. The calibration graphs are linear in the range of 0.01–300 μg L−1 and limits of detection (LODs) are in the range of 0.005–0.50 μg L−1. The relative standard deviations (RSDs, for 100 μg L−1 of MCPs, 50 μg L−1 of DCPs, 2.00 μg L−1 of TCPs, 1.00 μg L−1 of TeCPs and PCP in water) with and without using an internal standard are in the range of 0.9–5.5% (n = 7) and 1.2–6.4% (n = 7), respectively. The relative recoveries of well, tap and river water samples which have been spiked with different levels of CPs are in the range of 90.6–104.2%.

4 October 2011 in Journal of Chemistry
Verified
Journal Article
Open access
PDF file
EBEdris Bazrafshan
Edris Bazrafshan
HBHamed Biglari
Hamed Biglari
AMAmir Hossein Mahvi
Amir Hossein Mahvi
At present study the performance of electrocoagulation process using iron electrodes sacrificial anode has been investigated for removal of HA from artificial aqueous solution. The experiments were performed in a bipolar batch reactor with four iron electrode connected in parallel. Several working parameters, such as initial pH (3, 5, 7, and 9), electrical conductivity (50 V) and reaction time were studied in an attempt to achieve the highest removal capacity. Solutions of HA with concentration equal 20 mg L-1 were prepared. To follow the progress of the treatment, samples of 10 ml were taken at 15, 30, 45, 60, and 75 min interval. Finally HA concentration was measured by UV absorbance at 254 nm (UV254) and TOC concentration was measured by TOC Analyser. The maximum efficiency of HA removal which was obtained in voltage of 50 V, reaction time of 75 min, initial concentration 20 mg L-1, conductivity 3000 µS/Cm and pH 5, is equal to 92.69%. But for natural water samples at the same optimum condition removal efficiency was low (68.8 %). It can be concluded that the electrocoagulation process has the potential to be utilized for cost‐effective removal of HA from aqueous environments.