Rika Yano

Rika Yano

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Journal of Infection and Chemotherapy
Verified
Journal Article
Open access
RYRika Yano
Rika Yano
TSTomoko Shimoda
Tomoko Shimoda
RWReina Watanabe
Reina Watanabe
YKYasutoshi Kuroki
Yasutoshi Kuroki
TOTorahiko Okubo
Torahiko Okubo
HYHiroyuki Yamaguchi
Hiroyuki Yamaguchi
Previous works have demonstrated considerable variability in hospital cleanliness in Japan, suggesting that contamination is driven by factors that are currently poorly controlled. We undertook 16S rRNA sequence analysis to study population structures of hospital environmental microbiomes to see which factor(s) impacted contamination. One hundred forty-four samples were collected from surfaces of three hospitals with distinct sizes ("A": >500 beds, "B": 100-500 beds, "C": <100 beds). Sample locations of two ward types (Surgical and Internal) included patient room bed table (multiple) (4BT), patient overbed table (multiple) (4OT), patient room sink (multiple) (4S), patient room bed table (single) (SBT), patient overbed table (single) (SOT), patient room sink (single) (SS), nurse desk (ND), and nurse wagon (NW). Total DNA was extracted from each sample, and the 50 samples that yielded sufficient DNA were used for further 16S rRNA sequencing of hospital microbiome populations with cluster analysis. The number of assigned bacterial OTU populations was significantly decreased in hospital "C" compared to the other hospitals. Cluster analysis of sampling locations revealed that the population structure in almost all locations of hospital "C" and some locations in the other hospitals was very similar and unusually skewed with a family, Enterobacteriaceae. Interestingly, locations included patient area (4OT, 4BT, SBT) and nurse area (ND), with a device (NW) bridging the two and a place (4S and SS) shared between patients or visitors. We demonstrated diversity changes of hospital environmental microbiomes with a skewed population, presumably by medical staff pushing NWs or sinks shared by patients or visitors.

21 December 2015 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
TSTomoko Shimoda
Tomoko Shimoda
RYRika Yano
Rika Yano
SNShinji Nakamura
Shinji Nakamura
MYMitsutaka Yoshida
Mitsutaka Yoshida
JMJunji Matsuo
Junji Matsuo
HYHiroyuki Yamaguchi
Hiroyuki Yamaguchi
Our previous study into assessing hospital cleanliness in Japan by two common methods, ATP bioluminescence and the stamp agar method, revealed considerable variability in the data of both methods (BMC Research Notes, 7: 121, 2014). To investigate the reason(s) for the variability, we reanalyzed the data (n = 752) from the point of view of the material surface properties of sampling sites. Data obtained from surfaces with unknown properties and different purposes such as floor were omitted, and the remaining data (n = 488) were used for this study. The material surface properties on sampling sites were divided into six categories: melamine coated (n = 216), vinyl chloride (n = 16), stainless steel (n = 144), wood (n = 63), and acrylonitrile-butadiene styrene resin coated (n = 48). The data between individual material properties were compared. The ATP values of high-touch places were significantly different depending on the type of surface, but no significant difference in stamp values between material properties was seen, indicating that in contrast to stamp values, ATP-accumulation more depends on the physical properties of the material surface such as electronic charges or roughness. To confirm this, we assessed a degree of roughness on vinyl chloride material surface (disutilized floor samples actually used for each of the hospitals) by observation with scanning electron microscope (SEM). As a result, SEM observation similarly revealed considerable roughness on the materials, which may allow microbes to contaminate the materials without noticing it. Material properties must be considered when evaluating hospital cleanliness with ATP values, and provide a strong warning into evaluating hospital cleanliness.

4 March 2014 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
RWReina Watanabe
Reina Watanabe
TSTomoko Shimoda
Tomoko Shimoda
RYRika Yano
Rika Yano
YHYasuhiro Hayashi
Yasuhiro Hayashi
SNShinji Nakamura
Shinji Nakamura
HYHiroyuki Yamaguchi
Hiroyuki Yamaguchi
Background: Hospital cleanliness in hospitals with a tendency toward long-term care in Japan remains unevaluated. We therefore visualized hospital cleanliness in Japan over a 2-month period by two distinct popular methods: ATP bioluminescence (ATP method) and the standard stamp agar method (stamp method). Methods: The surfaces of 752 sites within nurse and patient areas in three hospitals located in a central area of Sapporo, Japan were evaluated by the ATP and stamp methods, and each surface was sampled 8 times in 2 months. These areas were located in different ward units (Internal Medicine, Surgery, and Obstetrics and Gynecology). Detection limits for the ATP and stamp methods were determined by spike experiments with a diluted bacterial solution and a wipe test on student tables not in use during winter vacation, respectively. Values were expressed as the fold change over the detection limit, and a sample with a value higher than the detection limit by either method was defined as positive. Results: The detection limits were determined to be 127 relative light units (RLU) per 100 cm2 for the ATP method and 5.3 colony-forming units (CFU) per 10 cm2 for the stamp method. The positive frequency of the ATP and stamp methods was 59.8% (450/752) and 47.7% (359/752), respectively, although no significant difference in the positive frequency among the hospitals was seen. Both methods revealed the presence of a wide range of organic contamination spread via hand touching, including microbial contamination, with a preponderance on the entrance floor and in patient rooms. Interestingly, the data of both methods indicated considerable variability regardless of daily visual assessment with usual wiping, and positive surfaces were irregularly seen. Nurse areas were relatively cleaner than patient areas. Finally, there was no significant correlation between the number of patients or medical personnel in the hospital and organic or microbiological contamination. Conclusions: Ongoing daily hospital cleanliness is not sufficient in Japanese hospitals with a tendency toward long-term care.

25 December 2018 in Japan Journal of Nursing Science
Verified
Journal Article
Closed access
PDF file
HKHiromi Kagamiyama
Hiromi Kagamiyama
NSNaomi Sumi
Naomi Sumi
YYYuko Yoshida
Yuko Yoshida
NSNaotaka Sugimura
Naotaka Sugimura
FNFumie Nemoto
Fumie Nemoto
RYRika Yano
Rika Yano

KWKazuhiro Watanabe
Kazuhiro Watanabe
NSNaotaka Sugimura
Naotaka Sugimura
ISInaho Shishido
Inaho Shishido
IKIssei Konya
Issei Konya
SYShinya Yamaguchi
Shinya Yamaguchi
RYRika Yano
Rika Yano
For nurses working long night shifts, it is imperative that they have the ability to take naps to reduce fatigue, and that an appropriate environment is prepared where such naps can be taken. We verified the effects of 90 min napping on fatigue and the associated factors among nurses working 16-h night shifts. We investigated 196-night shifts among 49 nurses for one month. Wearable devices, data logging devices, and questionnaires were used to assess nap parameters, fatigue, and environmental factors such as the napping environment, ways of spending breaks, and working environment. Nurses who nap at least 90 min on most night shifts had more nursing experience. Multivariable logistic regression analysis showed that the environmental factors significantly associated with total nap duration (TND) ≥ 90 min were noise, time spent on electronic devices such as cellphones and tablets during breaks, and nap break duration. The night shifts with TND ≥ 90 min showed lower drowsiness after nap breaks and less fatigue at the end of night shift compared to those with TND < 90 min. Nurses and nursing managers should recognize the importance of napping and make adjustments to nap for at least 90 min during long night shifts.

16 March 2021 in Nursing Open
Verified
Journal Article
Open access
PDF file
IKIssei Konya
Issei Konya
KNKotone Nishiya
Kotone Nishiya
RYRika Yano
Rika Yano
Aim: To evaluate the effectiveness of bed bath methods for skin integrity, skin cleanliness and comfort enhancement in adults.Design: A systematic review based on the PRISMA guidelines.Methods: We searched for quantitative studies published between 2004–2020, using the PubMed, MEDLINE and CINAHL. The remaining 25 studies were appraised by the JBI tool.Results: Only four of the included studies were of high quality. Studies of above moderate quality demonstrated that disposable towels were as effective as cotton towels for skin lesions and bacterial removal. Applying a hot towel maintained the skin barrier function and provided warmth; cotton towels were effective for cleaning even with weak pressure, and post‐bed bath moisturizer treatment contributed to skin integrity.Conclusion: Although various methods have been examined, the available evidence is inadequate for establishing best practices. It is necessary to verify empirical research with rigorous methodology involving elderly inpatients and to develop instruments that measure patients' comfort.