Jong-hwa Kwon

Dr. Jong-hwa Kwon

Electonics & Telecommunications Research Institute, Deajeon, Korea
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2017 in Energies
Verified
Journal Article
Open access
PDF file
KHKaram Hwang
Karam Hwang
JCJaeyong Cho
Jaeyong Cho
Dongwook KimDongwook Kim
Dongwook Kim
JPJaehyoung Park
Jaehyoung Park
JKJong-hwa Kwon
Jong-hwa Kwon
Seungyoung AhnSeungyoung Ahn
Seungyoung Ahn
This paper proposes an autonomous coil alignment system (ACAS) for electric vehicles (EVs) with dynamic wireless charging (DWC) to mitigate the reduction in received power caused by lateral misalignment between the source and load coils. The key component of the ACAS is a novel sensor coil design, which can detect the load coil’s left or right position relative to the source coil by observing the change in voltage phase. This allows the lateral misalignment to be estimated through the wireless power transfer (WPT) system alone, which is a novel tracking method for vehicular applications. Once misalignment is detected, the vehicle’s lateral position is self-adjusted by an autonomous steering function. The feasibility of the overall operation of the ACAS was verified through simulation and experiments. In addition, an analysis based on experimental results was conducted, demonstrating that 26% more energy can be transferred during DWC with the ACAS, just by keeping the vehicle’s load coil aligned with the source coil.

26 October 2016 in Environmental Health and Toxicology
Verified
Journal Article
Open access
PDF file
YCYong Min Cho
Yong Min Cho
HLHee Jin Lim
Hee Jin Lim
HJHoon Jang
Hoon Jang
KKKyung-Hee Kim
Kyung-Hee Kim
JCJaewook Choi
Jaewook Choi
Nam KimNam Kim
Nam Kim
This study analyzed the associations between mobile phone call frequency and duration with non-specific symptoms. This study was conducted with a population group including 532 non-patient adults established by the Korean Genome and Epidemiology Study. The pattern of phone call using a mobile phone was investigated through face-to-face interview. Structured methods applied to quantitatively assess health effects are Headache Impact Test-6 (HIT-6), Psychosocial Well-being Index-Short Form, Beck Depression Inventory, Korean-Instrumental Activities of Daily Living, Perceived Stress Scale (PSS), Pittsburgh Sleep Quality Index, and 12-item Short Form Health Survey where a higher score represents a higher greater health effect. The average daily phone call frequency showed a significant correlation with the PSS score in female subjects. Increases in the average duration of one phone call were significantly correlated with increases in the severity of headaches in both sexes. The mean (standard deviation) HIT-6 score in the subgroup of subjects whose average duration of one phone call was five minutes or longer was 45.98 (8.15), as compared with 42.48 (7.20) in those whose average duration of one phone call was <5 minutes. The severity of headaches was divided into three levels according to the HIT-6 score (little or no impact/moderate impact/substantial or severe impact), and a logistic regression analysis was performed to investigate the association between an increased phone call duration and the headache severity. When the average duration of one phone call was five minutes or longer, the odds ratio (ORs) and the 95% confidence intervals (CIs) for the moderate impact group were 2.22 and 1.18 to 4.19, respectively. The OR and 95% CI for the substantial or severe impact group were 4.44 and 2.11 to 8.90, respectively. Mobile phone call duration was not significantly associated with stress, sleep, cognitive function, or depression, but was associated with the severity of headaches.

1 October 2008
Verified
Conference Paper
Closed access
SKSang Il Kwak
Sang Il Kwak
DSDong-Uk Sim
Dong-Uk Sim
JKJong-hwa Kwon
Jong-hwa Kwon
In this paper, specific absorption rate (SAR) reduction at the PIFA type for a mobile phone using various types of EBG structure are tested. Two EBG structures, that is a via or a via-less, are designed. The EBG structures can reduce the surface wave and prevent the undesired radiation from the ground plane. Thus, the EBG structure which is designed for mobile terminal enables to comply with the exposure guideline. From the simulation and measured results demonstrated the reduction of the radiation pattern towards the direction of human head and the SAR value.

29 December 2016 in Environmental Health and Toxicology
Verified
Journal Article
Open access
PDF file
YCYong Min Cho
Yong Min Cho
HLHee Jin Lim
Hee Jin Lim
HJHoon Jang
Hoon Jang
KKKyung-Hee Kim
Kyung-Hee Kim
JCJaewook Choi
Jaewook Choi
Nam KimNam Kim
Nam Kim
The duration and frequency of mobile phone calls, and their relationship with various health effects, have been investigated in our previous cross-sectional study. This 2-year period follow-up study aimed to assess the changes in these variables of same subjects. The study population comprised 532 non-patient adult subjects sampled from the Korean Genome Epidemiology Study. The subjects underwent a medical examination at a hospital in 2012/2013 and revisited the same hospital in 2014/2015 to have the same examination for the characteristics of mobile phone use performed. In addition, to evaluate the effects on health, the Headache Impact Test-6 (HIT-6), Psychosocial Well-being Index-Short Form, Beck Depression Inventory, Korean-Instrumental Activities of Daily Living, Perceived Stress Scale, Pittsburgh Sleep Quality Index, and 12-item Short Form Health Survey were analyzed. For all these tests, the higher the score, the greater the effect on health. Variances between scores in all the indices in the baseline and follow-up surveys were calculated, and correlations of each index were analyzed. The average duration per call and HIT-6 score of the subjects decreased significantly compared with those recorded two years ago. The results showed a slight but significant correlation between call duration changes and HIT-6 score changes for female subjects, but not for males. HIT-6 scores in the follow-up survey significantly decreased compared to those in the baseline survey, but long-time call users (subjects whose call duration was ≥5 minutes in both the baseline and follow-up surveys) had no statistically significant reduction in HIT-6 scores. This study suggests that increased call duration is a greater risk factor for increases in headache than any other type of adverse health effect, and that this effect can be chronic.

7 April 2010 in ETRI Journal
Verified
Journal Article
Open access
PDF file
JKJong-hwa Kwon
Jong-hwa Kwon
SKSang Il Kwak
Sang Il Kwak
DSDong‐Uk Sim
Dong‐Uk Sim
JYJong-Gwan Yook
Jong-Gwan Yook
To supply a power distribution network with stable power in a high-speed mixed mode system, simultaneous switching noise caused at the multilayer PCB and package structures needs to be sufficiently suppressed. The uniplanar compact electromagnetic bandgap (UC-EBG) structure is well known as a promising solution to suppress the power noise and isolate noise-sensitive analog/RF circuits from a noisy digital circuit. However, a typical UC-EBG structure has several severe problems, such as a limitation in the stop band's lower cutoff frequency and signal quality degradation. To make up for the defects of a conventional EBG structure, a partially located EBG structure with decoupling capacitors is proposed in this paper as a means of both suppressing the power noise propagation and minimizing the effects of the perforated reference plane on the signal quality. The proposed structure is validated and investigated through simulation and measurement in both frequency and time domains.

17 February 2020 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Jung-hwan HwangJung-hwan Hwang
Jung-hwan Hwang
HPHyun Ho Park
Hyun Ho Park
CHChang Hee Hyoung
Chang Hee Hyoung
JKJong-hwa Kwon
Jong-hwa Kwon
For a small-sized shielding enclosure, an infinitesimal monopole antenna is installed inside an enclosure to measure the quality factor and the shielding effectiveness. The characteristic of the monopole antenna, however, affects the measurement of the quality factor and the shielding effectiveness. This article proposes a new measurement method that does not require any antenna installation inside the enclosure. Instead, the proposed method utilizes an aperture on the enclosure surface. A theoretical model is derived for the enclosure response, which represents a response of the enclosure when a pulse signal is incident to the enclosure in the nested reverberation chamber. The response model is used to measure the quality factor and the shielding effectiveness, respectively. The enclosure response affected by an aperture on the enclosure surface is measured, and the measured response is then used to calculate the quality factor by comparing it with the response model. The response model also is used to measure the shielding effectiveness. The enclosure responses are measured with two aperture conditions, respectively, and the shielding effectiveness is calculated using the measured responses. The proposed method is advantageous in that the quality factor and the shielding effectiveness of a small-size enclosure can be accurately measured without being affected by the quality factor of the monopole antenna.