The kurtosis from the diffusion kurtosis imaging model demonstrated correlations with both the World Health Organization and poorly differentiated cluster grades, particularly the latter, and perfo... Purpose To determine the correlation between diffusion kurtosis imaging (DKI)–derived parameters and prognostic factors for rectal adenocarcinoma. Materials and Methods This study was approved by t...
Objectives: To evaluate inter- and intra- scan mode and scanner repeatability and reproducibility of radiomics features within and between single-energy CT (SECT) and dual-energy CT (DECT). Methods: A standardized phantom with sixteen rods of clinical-relevant densities was scanned on seven DECT-capable scanners and three SECT-only scanners. The acquisition parameters were selected to present typical abdomen-pelvic examinations with the same voxel size. Images of SECT at 120 kVp and corresponding 120 kVp-like virtual monochromatic images (VMIs) in DECT which were generated according to scanners were analyzed. Regions of interest were drawn with rigid registrations to avoid variations due to segmentation. Radiomics features were extracted via Pyradiomics platform. Test-retest repeatability was evaluated by Bland-Altman analysis for repeated scans. Intra-scanner reproducibility for different scan modes was tested by intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). Inter-scanner reproducibility among different scanners for same scan mode was assessed by coefficient of variation (CV) and quartile coefficient of dispersion (QCD). Results: The test-retest analysis presented that 92.91% and 87.02% of the 94 assessed features were repeatable for SECT 120kVp and DECT 120 kVp-like VMIs, respectively. The intra-scanner analysis for SECT 120kVp vs DECT 120 kVp-like VMIs demonstrated that 10.76% and 10.28% of features were with ICC > 0.90 and CCC > 0.90, respectively. The inter-scanner analysis showed that 17.09% and 27.73% of features for SECT 120kVp were with CV < 10% and QCD < 10%, and 15.16% and 32.78% for DECT 120 kVp-like VMIs, respectively. Conclusions: The majority of radiomics features were non-reproducible within and between SECT and DECT. Key Points: • Although the test-retest analysis showed high repeatability for radiomics features, the overall reproducibility of radiomics features within and between SECT and DECT was low. • Only about one-tenth of radiomics features extracted from SECT images and corresponding DECT images did match each other, even their average photon energy levels were considered alike, indicating that the scan mode potentially altered the radiomics features. • Less than one-fifth of radiomics features were reproducible among multiple SECT and DECT scanners, regardless of their fixed acquisition and reconstruction parameters, suggesting the necessity of scanning protocol adjustment and post-scan harmonization process.
Objective: To update the systematic review of radiomics in osteosarcoma. Methods: PubMed, Embase, Web of Science, China National Knowledge Infrastructure, and Wanfang Data were searched to identify articles on osteosarcoma radiomics until May 15, 2022. The studies were assessed by Radiomics Quality Score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD) statement, Checklist for Artificial Intelligence in Medical Imaging (CLAIM), and modified Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The evidence supporting radiomics application for osteosarcoma was rated according to meta-analysis results. Results: Twenty-nine articles were included. The average of the ideal percentage of RQS, the TRIPOD adherence rate and the CLAIM adherence rate were 29.2%, 59.2%, and 63.7%, respectively. RQS identified a radiomics-specific issue of phantom study. TRIPOD addressed deficiency in blindness of assessment. CLAIM and TRIPOD both pointed out shortness in missing data handling and sample size or power calculation. CLAIM identified extra disadvantages in data de-identification and failure analysis. External validation and open science were emphasized by all the above three tools. The risk of bias and applicability concerns were mainly related to the index test. The meta-analysis of radiomics predicting neoadjuvant chemotherapy response by MRI presented a diagnostic odds ratio (95% confidence interval) of 28.83 (10.27–80.95) on testing datasets and was rated as weak evidence. Conclusions: The quality of osteosarcoma radiomics studies is insufficient. More investigation is needed before using radiomics to optimize osteosarcoma treatment. CLAIM is recommended to guide the design and reporting of radiomics research.