Gilberto Abate

Dr. Gilberto Abate

Departamento de Química, Universidade Federal do Paraná, Centro Politécnico, Curitiba 81531-980, Brazil

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2021 in Minerals
Verified
Journal Article
Open access
PDF file
Jorge Cesar MasiniJorge Cesar Masini
Jorge Cesar Masini
GAGilberto Abate
Gilberto Abate
Natural and modified clay minerals have been extensively used for the adsorption/desorption of organic substances, especially pesticides, from waters and wastewater, aiming at pollution control and more efficient use of the herbicides through controlled release. While natural clay minerals efficiently remove organic cations such as paraquat and diquat, the adsorption of anionic or neutral species demands surface chemical modification with, for instance, quaternary ammonium salts containing long alkyl chains. Basic pesticides, on the other hand, are better absorbed in clay minerals modified with polycations. Kinetic studies and adsorption/desorption isotherms provide the parameters needed to evaluate the clay mineral’s adsorptive performance towards the pollutant target. However, the direct comparison of these parameters is complicated because the experimental conditions, the analytical techniques, the kinetic and isotherm models, and the numerical fitting method differ among the various studies. The free-energy-related Langmuir constant depends on the degree of site occupation; that is, it depends on the concentration window used to construct the adsorption isotherm and, consequently, on the analytical technique used to quantify the free concentrations. This paper reviews pesticides’ adsorption on natural and modified clay minerals and proposes guidelines for designing batch adsorption/desorption studies to obtain easily comparable and meaningful adsorption parameters. Articles should clearly describe the experimental conditions such as temperature, contact time, total concentration window, the solution to adsorbent ratio, the analytical technique, and its detection and quantification limits, besides the fitting models. Research should also evaluate the competitive effects of humic substances, colloidal inorganic particles, and ionic strength to emulate real-world adsorption experiments.

1 November 2012 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
SFSérgio Ribeiro Frois
Sérgio Ribeiro Frois
MGMarco Tadeu Grassi
Marco Tadeu Grassi
MCMônica Soares de Campos
Mônica Soares de Campos
GAGilberto Abate
Gilberto Abate
In the present work a simple method was proposed for the determination of Cr(VI) in water samples using a previous separation of Cr(III) by the low cost sorbent montmorillonite, followed by separation of the solid phase and subsequent quantification of Cr(VI) employing ICP-OES. A complete Cr(III) removal was observed after only 1 minute of contact time between 25 mg of the clay mineral montmorillonite saturated with potassium ions (MTK) and the aqueous sample. On the other hand, the Cr(VI) remained in solution, yielding a suitable separation of the species. The method presented appropriate accuracy and precision in comparison with the official method of diphenylcarbazide (DPC), showing a good performance for Cr(VI) quantification in effluent water samples, with 0.20 and 0.70 μg L−1 for the Limit of Detection (LOD) and the Limit of Quantification (LOQ), respectively. Based on the experimental results, MTK showed remarkable characteristics to be used as a sorbent phase for an easy and fast separation of chromium species and consequently to provide the speciation analysis.

1 February 2016 in Talanta
Verified
Journal Article
Open access
RDRafael Garrett Dolatto
Rafael Garrett Dolatto
IMIara Messerschmidt
Iara Messerschmidt
BPBetânia Fraga Pereira
Betânia Fraga Pereira
RMRosane Martinazzo
Rosane Martinazzo
GAGilberto Abate
Gilberto Abate
This work proposes a liquid-phase microextraction (LPME) method to extract the highly polar compounds phenol (Ph), o-cresol (o-Cr), m-cresol (m-Cr), p-cresol (p-Cr), and 2,4-dimethylphenol (2,4-DMP) from aqueous matrices. The first extraction step of the LPME method employed a common volumetric flask and n-octanol, and the second extraction step used NaOH as the acceptor phase. The optimized extraction conditions were 900 μL of n-octanol as the extraction solvent, NaOH at 0.60 mol L(-1) as the acceptor phase, an extraction time of 5.0 min, HCl at 0.01 mol L(-1) and NaCl at 20.0% as the donor phase, and an extraction temperature of 20.0°C. The analysis of 50.0 mL of aqueous sample, pretreated under the optimized LPME conditions, afforded a limit of detection (LOD) between 0.3 and 3.5 μg L(-1), a limit of quantification (LOQ) between 1.2 and 11.6 μg L(-1), and a linear range from 2.50 to 50.0 μg L(-1) for Ph, o-Cr, m-Cr and p-Cr and from 12.5 to 250 μg L(-1) for 2,4-DMP. The proposed LPME method was a successful sample preparation strategy, and allowed for precise and accurate quantification of polar phenolic compounds in aqueous matrices such as tap water, river water, groundwater, and seawater, and also in a soil extract. The recovery values ranged from 72.5% to 126.0%, and the relative standard deviation was between 0.3 and 11.5%.

14 August 2023 in Chemosphere
Verified
Journal Article
Closed access
FFFernando Fabriz
Fernando Fabriz
IAImisi M. Arowojolu
Imisi M. Arowojolu
MCMaria C. Canela
Maria C. Canela
RFRodrigo S. Ferreira
Rodrigo S. Ferreira
AFAndreia Neves Fernandes
Andreia Neves Fernandes
WWWalter Waldman
Walter Waldman

1 March 2013 in Journal of the Brazilian Chemical Society
Verified
Journal Article
Open access
PDF file
MAMaristela F. Amadori
Maristela F. Amadori
GCGilcélia A. Cordeiro
Gilcélia A. Cordeiro
CRCaio C. Rebouças
Caio C. Rebouças
PPPatricio G. Peralta-Zamora
Patricio G. Peralta-Zamora
MGMarco T. Grassi
Marco T. Grassi
GAGilberto Abate
Gilberto Abate

17 July 2012 in The Analyst
Verified
Journal Article
Closed access
PDF file
VSVanessa Cristina Gonçalves dos Santos
Vanessa Cristina Gonçalves dos Santos
MGMarco Tadeu Grassi
Marco Tadeu Grassi
MCMônica Soares de Campos
Mônica Soares de Campos
PPPatricio Guillermo Peralta-Zamora
Patricio Guillermo Peralta-Zamora
GAGilberto Abate
Gilberto Abate
In this work a procedure for mercury determination by Flow Injection-Cold Vapor Generation-Inductively Coupled Plasma Optical Emission Spectrometry (FI-CVG-ICP OES) has been developed. The system uses a small homemade glass separator constructed to drive the Hg vapor to the plasma. An evolutionary operation factorial design was used to evaluate the optimal experimental conditions for mercury vapor generation, aiming at the low consumption of reagents, the improvement of the analytical signal and consequently greater sensitivity. The procedure allowed the determination of mercury and showed excellent linearity for the concentration range from 0.50 μg L−1 to 100.0 μg L−1, with Limits of Detection (LOD) and Quantification (LOQ) of 0.11 μg L−1 and 0.36 μg L−1, respectively, and a sampling rate of 36 analyses per hour. The optimized procedure showed good accuracy and precision, and the method was validated by the analysis of two certified reference materials: Buffalo River Sediment (NIST 2704) and human hair (IAEA 085). A good agreement with the certified values was achieved, with recovery values of 99% and 98% and relative standard deviation close to 2%.