Duojin Wang

Duojin Wang

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2022 in Expert Systems with Applications
Verified
Journal Article
Closed access
JLJiawan Liu
Jiawan Liu
DWDuojin Wang
Duojin Wang
QLQinglian Lin
Qinglian Lin
MDMeikui Deng
Meikui Deng

30 October 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
DWDuojin Wang
Duojin Wang
QMQingyun Meng
Qingyun Meng
QMQiaoling Meng
Qiaoling Meng
XLXinwei Li
Xinwei Li
HYHongliu Yu
Hongliu Yu
Improvement in hand function to promote functional recovery is one of the major goals of stroke rehabilitation. This paper introduces a newly developed exoskeleton for hand rehabilitation with a user-centered design concept, which integrates the requirements of practical use, mechanical structure and control system. The paper also evaluated the function with two prototypes in a local hospital. Results of functional evaluation showed that significant improvements were found in ARAT (P=0.014), WMFT (P=0.020) and FMA_WH (P=0.021). Increase in the mean values of FMA_SE was observed but without significant difference (P=0.071). The improvement in ARAT score reflects the motor recovery in hand and finger functions. The increased FMA scores suggest there is motor improvement in the whole upper limb, and especially in the hand after the training. The product met patients’ requirements and has practical significance. It is portable, cost effective, easy to use and supports multiple control modes to adapt to different rehabilitation phases.

17 February 2023 in Medical Engineering & Physics
Verified
Journal Article
Closed access
DWDuojin Wang
Duojin Wang
XGXiaoping Gu
Xiaoping Gu
HYHongliu Yu
Hongliu Yu
In recent years, lower limb exoskeletons (LLEs) have received much attention due to the potential to help people with paraplegia regain the ability of upright-legged locomotion. However, one major hindrance to converting prototypes into actual products is the lack of a balance recovery function. Locomotion intentions can be the first step for balance assistance. Therefore, its significance continues to grow. Many researchers focus on this topic, but there is a lack of a general discussion on the research phenomenon. Therefore, the purpose of this work is to systematize these data and benefit future research. This review is divided into two parts, the location of sensors/devices and the evaluation criteria of algorithms, which are the main components of locomotion intentions. We found that sensor/device placement is still concentrated in the lower limbs, but most researchers have found the importance of the chest. The peak power of the signal collected from the chest may be overestimated because it undergoes higher vertical velocity and acceleration during a rotation. However, despite the differences in peak power between the upper and lower back, high correlations were found for the tasks, especially from sitting to standing. Since peak power is based on vertical acceleration and velocity, it can be considered a metric that is more robust to changes in sensor location. Therefore, data acquisition from the chest is effective. In this paper, it is pointed out that sensors placed on the chest may have a tendency to change, as some researchers have realized in the field of locomotion intention recognition. In the evaluation criteria, we also found that deep learning algorithm (such as Back Propagation Artificial Neural Network (BPANN)) is outstanding, and Support Vector Machine (SVM) is the most cost-effective algorithm. In terms of accuracy, sensitivity, and specificity, BPANN achieved nearly 100%. SVM has different types; the best one achieves 98% accuracy, 100% sensitivity, and 100% specificity. But it also has 87.8% accuracy, which is not stable. Convolutional Neural Networks (CNN) can be used for image classification and have an accuracy of around 87%. Compared to the above two algorithms, CNN may have lower performance. Other algorithms also have higher accuracy, sensitivity, and specificity. These evaluation criteria, however, were not all ideal at the same time. Based on these results, we also point out the existing problems. In general, the application of these algorithms to LLE can contribute to its intention recognition, which can be helpful in balancing research. Finally, this can help make LLE more suitable for daily use.

4 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YJYangzheng Jiang
Yangzheng Jiang
DWDuojin Wang
Duojin Wang
JYJiming Ying
Jiming Ying
PCPengfei Chu
Pengfei Chu
YQYu Qian
Yu Qian
WCWen-Ming Chen
Wen-Ming Chen
Flatfoot is a common musculoskeletal deformity. One of the most effective treatments is to wear individually customized plantar pressure-based insoles to help users change the abnormally distributed pressure on the pelma. However, most previous studies were divided only into several plantar areas without detailed plantar characteristic analysis. In this study, a new insole is designed which redistributes pressure following the analysis of characteristic points of plantar pressure, and practical evaluation during walking of subjects while wearing the insole. In total, 10 subjects with flexible flatfeet have participated in the performance of gait experiments by wearing flat insoles, orthotic insoles, and plantar pressure redistribution insoles (PPRI). The results showed that the stance time of PPRI was significantly lower than that of the flat insoles under slow gait. PPRI in the second to third metatarsal and medial heel area showed better unloading capabilities than orthotic insoles. In the metatarsal and heel area, the PPRI also had its advantage in percentage of contact area compared to flat insole and orthotic insole. The results prove that PPRI improves the plantar pressure distribution and gait efficiency of adults with flexible flatfeet, and can be applied into clinical application.

14 January 2019 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
QLQingLian Lin
QingLian Lin
DWDuojin Wang
Duojin Wang
A well-design facility layout planning refers to the reduction of the operation cost in the manufacturing and service industry. This work consists of reliability analysis of facility layout for an operating theatre; it aims at proposing a new evaluation approach, which integrated the fuzzy analytic hierarchy process and human reliability tool, for optimization of facility layout design with safety and human factors in an operating theatre. Firstly, the systematic layout planning is used to design the layout schemes on the basis of field investigations. Then, the criteria system is proposed based on human reliability analysis from four perspectives: software, hardware, environment, and liveware. Finally, the fuzzy analytic hierarchy process, a fuzzy extension of the multicriteria decision-making technique analytic hierarchy process, is used to compare these layout schemes based on the criteria system. The results that are obtained reveal interesting properties of facility layout planning in hospitals. It reveals that decision in selecting a suitable layout must meet not only the strategies and goals of the system but also meet the safety, security, and reliability of the system.

30 April 2019 in BMC Public Health
Verified
Journal Article
Open access
PDF file
DWDuojin Wang
Duojin Wang
JWJing Wu
Jing Wu
In China, reprocessing and reuse of single-use medical devices (SUDs) are banned. However, the actual situation has not been reported so far. The study aims to clarify the perceptions and concerns of various sectors of the community on the reuse of SUDs, and whether such practice exists. In addition, we are also wondering how acceptable the respondents are on this matter. A cross-sectional study based on a national survey which was conducted on the professional online questionnaire survey platform ( www.wjx.cn ) from July 26 to August 4, 2015. We analyzed the data according to the work fields, sex, age, education level, professional background and participants’ answers to 49 other questions. Five hundred forty-four nationwide respondents belong to nine different work fields. In general, participants had positive attitudes towards the reprocessing and reuse of SUDs. However, many respondents doubted the hygienic and functional safety of the reprocessed SUDs. They also tended to think that the reuse of SUDs should have lower prices and more technical training as well as patient advocacy. Further analysis demonstrated the work fields, education level and professional background of respondents were statistically associated with their responses to certain questions. The research indicated that although the reuse of SUDs is prohibited legally in China, there were extensive reprocessing and reuse in hospitals. Most responses tended to accept reprocessed SUDs if safety and low prices were guaranteed. These existing contradictions and the lack of relevant research led to policy makers in China will confront numerous challenges in building and improving this use system of medical devices to meet escalating demands of social sectors.