Xiao Liang

Dr. Xiao Liang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Journal of Neurotrauma
Verified
Journal Article
Closed access
JZJiachen Zhuo
Jiachen Zhuo
PRPrashant Raghavan
Prashant Raghavan
MSMuhan Shao
Muhan Shao
SRSteven R Roys
Steven R Roys
XLXiao Liang
Xiao Liang
RGRao Gullapalli
Rao Gullapalli
The perivascular space (PVS) is important to brain waste clearance and brain metabolic homeostasis. Enlarged PVS (ePVS) becomes visible on MRI and is best appreciated on T2-weighted (T2w) images. Quantification of ePVS is however challenging because standard-of-care T1-weighted (T1w) and T2w images are often obtained as 2D acquisition, whereas accurate quantification of ePVS normally requires high-resolution volumetric 3D T1w and T2w images. The purpose of this study is to investigate the use of a deep learning based super-resolution technique to improve ePVS quantification from 2D T2w images for application in traumatic brain injury (TBI) patients. We prospectively recruited 26 volunteers (Age: 31±12yrs, 12M/14F) where both 2D T2w and 3D T2w were acquired along with 3D T1w images to validate the ePVS quantification using super-resolution T2w images. We then applied the super-resolution method to retrospectively acquired 2D T2w images in 41 chronic TBI patients (Age: 41±16yrs, 32M/9F). ePVS volumes were automatically quantified within the whole brain white matter and major brain lobes (temporal, parietal, frontal, occipital) in all subjects. Pittsburgh Sleep Quality Inventory (PSQI) was obtained on all TBI patients. Compared to the Silver Standard (3D T2w), in the validation study, the super-resolution T2w provided similar whole brain white matter ePVS volume (r=0.98, p<0.0001), and similar age-related ePVS burden increase (r = 0.80, p < 0.0001). In the patient study, TBI patients with poor sleep showed a higher age-related ePVS burden increase than those with good sleep. Sleep status is a significant interaction factor in the whole brain (p = 0.047) and the frontal lobe (p = 0.027). We demonstrate that images produced by super-resolution of 2D T2w images can be automatically analyzed to produce comparable results to that obtained by 3D T2 volumes. Reliable age-related ePVS burden across the whole brain white matter was observed in all subjects. Poor sleep, affecting the glymphatic function, may contribute to the accelerated increase of ePVS burden following TBI.

30 May 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
BLBo Li
Bo Li
YLYiran Li
Yiran Li
XLXiao Liang
Xiao Liang
AMAmnah Mahroo
Amnah Mahroo
MTManuel Taso
Manuel Taso
ZWZe Wang
Ze Wang
Purpose: To develop a slice‐wise blurring‐free and densely sampled TE‐resolved multiple‐TE (mTE) ASL sequence (TASL) for measuring blood–brain barrier (BBB) water exchange time. Methods: A 3D TSE spiral‐readout pCASL sequence was modified to enable TE‐resolved acquisition. Signals at mTEs from a single kz partition were acquired within a single shot, and the acquisition was repeated until all required kz partitions were covered. In vivo experiments were conducted on healthy volunteers using both a conventional pCASL sequence and the proposed TASL sequence. Signal intensity modulation, perfusion SNR, and quantitative parameters including cerebral blood flow (CBF), arterial transit time (ATT), intravoxel transit time ( ITT ), and water exchange time ( T exch ) were evaluated. Test–retest scans were conducted to assess reproducibility. Results: Compared with the conventional mTE acquisition, TASL eliminates T 2 decay‐induced slice‐wise intensity modulation and blurring, yielding higher whole‐brain perfusion SNR across all TEs and PLDs. Estimates of CBF and ATT showed negligible differences between the two methods (both < 1%), whereas mean T exch and ITT values were 18.2% and 9.05% higher, respectively, with TASL. Bland–Altman analysis showed minimal bias, with 95% of differences within the limits of agreement (mean±1.96 SD). The inter‐session ICC and wsCV of CBF, ATT, T exch , and ITT in gray matter are 0.86% and 8.38%, 0.96% and 1.98%, 0.93% and 4.04%, and 0.95% and 4.32%, respectively. Conclusion: TASL eliminates signal intensity modulation and blurring artifacts while providing densely sampled TE for parametric fitting. It may be a valuable tool for accurate and reliable quantification of cerebral perfusion and BBB permeability.

29 October 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
XLXiao Liang
Xiao Liang
LPLi Pan
Li Pan
ENErez Nevo
Erez Nevo
MSMumtaz Hussain Soomro
Mumtaz Hussain Soomro
SRSteve Roys
Steve Roys
JZJiachen Zhuo
Jiachen Zhuo
Objective. To develop time-resolved multi-cycle MRI (TRMC-MRI) for 4D lung imaging that can capture respiration-induced cycle-to-cycle variations in the internal anatomy. Approach. Golden-angle 3D stack-of-stars gradient echo data were continuously acquired during free breathing for 2 minutes, or 4000 radial views. Thoracoabdominal surface motion was concurrently tracked by four MR-compatible electromagnetic motion tracking sensors at a frequency of one tracking event for every two radial views. A radial view was a stack of k-space radial spokes acquired with the same radial angle for all the partition phase encoding steps. A continuous breathing state was defined for each tracking event, and the two radial views associated with each tracking event, by the principal component (PC) scores based on the sensor positions. To reconstruct a dynamic volume for a tracking event, radial views with similar breathing states to the tracking event in question were collected from the entire acquisition to fill the k-space. Sensitivity maps were estimated from all the acquired radial views. Reconstruction of dynamic volumes was performed with parallel imaging with total variation regularization. The proposed method was performed on four healthy volunteers (Male/Female: 3/1, Age: 30 ± 2.3 years) in the right lung. Main results. Thoracoabdominal surface tracking showed cycle-to-cycle breathing variability (coefficients of variation for period: 8%–23%, for amplitude: 7%–36%) despite instruction of breathing regularly. Dynamic lung volumes covering 320 × 320 × 24 mm 3 were generated at every 60.6 ms for the entire 2-minute acquisition consisting of on average 23.2 (range: 18–34) breathing cycles. Considerable breathing variations were captured in time-resolved multi-cycle breathing motion. Significance. The surface tracking-assisted TRMC-MRI framework can provide critical breathing variations information for MR-guided lung radiotherapy, including treatment planning, motion modeling and prediction, and training for real-time MR in the treatment room.

27 October 2026 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
EGErshad Hassanpour Golagani
Ershad Hassanpour Golagani
YLYiran Li
Yiran Li
XLXiao Liang
Xiao Liang
BLBo Li
Bo Li
YCYulin Chang
Yulin Chang
ZWZe Wang
Ze Wang
Purpose: Multi‐post‐labeling delays (PLDs) multi‐echo times (TEs) arterial spin labeling (ASL) MRI enables simultaneous quantification of cerebral blood flow (CBF), arterial transit time (ATT), and blood–brain barrier (BBB) water exchange, but requires long scan times due to the combination of multi‐TEs, PLDs, and repeated control–label acquisitions. A five‐dimensional (5D) acquisition and reconstruction framework was developed to enable accelerated multi‐parametric ASL. Methods: A coordinated undersampling strategy was designed across in‐plane k‐space, through‐plane k‐space, TE, and control–label measurement dimensions, achieving a combined acceleration factor of approximately 28. Reconstruction was performed using a Kronecker‐structured subspace model that exploited low‐rank correlations along the TE and control–label dimensions. Sparsity regularization was applied in the subspace coefficient domain, and temporal bases were estimated from a single fully sampled middle slice. The framework was evaluated using in vivo echo‐time‐resolved ASL (TASL) datasets from eight subjects. Results: The proposed reconstruction outperformed a matched compressed sensing (CS) reconstruction across all echo times, yielding higher structural similarity index measure (SSIM) and peak signal‐to‐noise ratio (PSNR), with the largest improvements observed under severe undersampling ( R ≈28) and at late echo times. Higher‐fidelity CBF, ATT, BBB, and intravascular transit time (ITT) maps were obtained, with the greatest gains observed for BBB and ITT. Test–retest reliability, assessed using intraclass correlation coefficient (ICC), remained comparable to fully sampled reference data. Conclusion: Coordinated multi‐dimensional undersampling combined with Kronecker subspace reconstruction enables highly accelerated multi‐parametric ASL while preserving image quality, quantitative parameter estimation, and test–retest reliability, supporting clinically feasible acquisition times.

25 February 2026 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
MSMumtaz Hussain Soomro
Mumtaz Hussain Soomro
XLXiao Liang
Xiao Liang
SRSteve Roys
Steve Roys
JXJunliang Xu
Junliang Xu
NLNarottam Lamichhane
Narottam Lamichhane
Amit SawantAmit Sawant
Amit Sawant
Objective . To validate a respiratory motion model that uses real-time electromagnetic (EM) surface tracking acquired concurrently with time-resolved multi-cycle 4D MRI (TRMC-MRI) to estimate respiration-induced changes within the entire irradiated volume. Approach . Four volunteer participants with no self-reported history of lung cancer or other pulmonary disease underwent TRMC-MRI using a golden-angle stack-of-stars 3D GRE sequence while breathing freely for 2 min. Concurrently, real-time thoracoabdominal surface motion was recorded using four MR-compatible electromagnetic (EM) sensors (EndoScout II). Each MR volume was temporally aligned with corresponding EM data, resulting in 2,000 paired samples per participant. Deformation vector fields (DVFs) were generated through deformable image registration between a selected reference volume and all subsequent volumes. To capture temporal anatomical changes, additional DVFs were computed via consecutive volume-to-volume registration (e.g., volume 2 to 1, 3 to 2, and so on). Two machine learning models were developed to map surface motion to internal DVFs using dimensionality reduction: one employing Principal Component Analysis (PCA), and the other using Independent Component Analysis (ICA). Estimated DVFs were applied to the reference volume to reconstruct dynamic MR images, which were evaluated against ground truth using mutual information (MI) and an image-derived diaphragm profile–based root mean squared error (RMSE). Main results . Our preliminary results demonstrated that both PCA- and ICA-based models achieved comparable MI scores (mean 62%; one-way ANOVA, p > 0.05). Adaptive median filtering significantly improved MI to approximately 66% on average (one-way ANOVA, p < 0.001), outperforming no filtering across all participants (Tukey’s HSD, p < 0.05). Diaphragm profile analysis showed close agreement with ground truth, with mean RMSE of 3.77–4.71 mm (SD: 1.07–1.63 mm). Significance . This proof-of-concept study demonstrates the feasibility of a non-invasive respiratory motion model derived from EM-based surface tracking combined with TRMC-MRI, with potential applications in MR-guided and conventional radiotherapy.