Background: The main objective of this systematic review was to present the outcomes of the treatment with zygomatic implants (ZIs) in the rehabilitations of atrophic upper jaw. Findings: An electronic database search in PubMed, along with a manual search, taking into account language and study period, was performed by two observers; any type of clinical trial and series that included the use of ZIs was used. In the search strategy, the following search terms were used: zygom* AND dental (Implant OR implants) AND edentulous NOT (biomechanic* OR finite element) NOT cadaver. The search was limited to English language, full text, and humans. Literature reviews and clinical case reports were not considered. Forty-two articles published between March 2003 and April 2019 were included in this analysis. The cases of 1247 patients were recovered; these patients received 2919 ZIs. Fifty-two ZIs were removed during the follow-up time. The survival rate of these implants was 98.22%, with a minimum follow-up of 1 month and a maximum of 228 months. Different surgical techniques were used to place ZIs; however, the intrasinusal technique was the most used (23 studies). Post-surgical sinusitis was the most common complication reported in the studies (39 cases). Conclusions: Based on this review, ZIs were commonly used for rehabilitation of patients with atrophic upper jaw. The survival rates presented were high, and the surgical technique is dependent on the professional experience and the local anatomy. However, it needed additional clinical evidence on bone resorption, esthetic outcomes, and physiological characteristics.
21 July 2020 in International Journal of Implant Dentistry
Background: In the long-term success of a dental implant, the reliability and stability of the implant-abutment interface are important. Studies of maximum force of dental implants with different loading values have been used. This study aims to evaluate the influence of the oblique cyclic loading on the maximum force supported in one-piece and two-piece abutments installed on internal tapered implants.Findings: Sixty implants and sixty prosthetic abutments were divided into six groups (n= 10): G1 and G2 (two-piece abutments with 16°), G3 and G4 (two-piece abutments with 11.5°), and G5 and G6 (one-piece abutments with 11.5°). A 2-Hz cyclic loading was applied to specimens of G2, G4, and G6, with a number of cycles of 2,400,000. All specimens were inclined by 30° from the vertical axis, and a vertical loading was applied over the tapered connections (ISO 14801). Then, the maximum force was tested by applying a static compression load on the specimens of the 6 groups tested (30°) at a rate of 0.5 mm/s. Statistical analysis was performed using the Shapiro-Wilk (p> 0.05) and Levene (p= 0.789) tests to determine if the data presented homoscedasticity and the Tukey test for multiple comparisons. Tukey test showed that the maximum force supported by G1 and G2 was not affected by the cyclic load, while in G3 and G4 it decreased significantly when subjected to the cyclic load. The G5 and G6 had a significant increase in maximum force supported when subjected to cyclic load.Conclusions: Cyclic loading influenced the maximum force supported of G4 and G6 but did not influence G2.
The aim of this study was to assess the effect of a diamond-like carbon (DLC) coating on the removal torque of prefabricated implant screws after cyclic loading. Four groups with two crowns supported by two implants (n = 5) were obtained according to splinted and nonsplinted prosthesis, using titanium or DLC screws (splinted crowns with titanium screw [STi], splinted crowns with DLC screw [SC], nonsplinted crowns and titanium screw [NSTi], and nonsplinted crowns and DLC screw [NSC]). The prosthetic screws were tightened at 32 Ncm and retightened, and the specimens were submitted to 106 mechanical cycles (4 Hz/98 N). After cyclic loading, loosening torque was evaluated, and the final measurements were performed. Data were analyzed by two-way analysis of variance and Tukey's test (α = .005). There was statistically significance in the interaction of screw × splinting (P = .003). For the group that used titanium screws, NSTi showed smaller removal torque compared with STi. It was concluded that the use of the DLC coating screws in nonsplinted prosthesis maintain the torque after cyclic loading.
1 January 2021 in The International Journal of Oral and Maxillofacial Implants
Purpose: The aim of this in vitro study was to evaluate the mechanical behavior regarding dynamic fatigue of different implant-abutment connections and the unitary indication of abutments for all regions of the mouth. Materials and Methods: This experimental study developed according to international standards (ISO 14801:2007) was performed using five types of implants and abutments: G1-external hex smart implant and 17-degree universal abutment (EHS); G2-cortical external hex implant and 17-degree universal abutment (EHTi); G3-internal hex implant and 30-degree universal abutment (IH); G4-Morse taper implant (11.5 degrees) and 17-degree universal abutment (MT11.5); and G5-Morse taper implant (16 degrees) and 30-degree universal abutment (MT16). A 15-Hz cyclic loading was applied to the specimens with the maximum number of cycles set at 5 x 10(6). Success was defined when three samples supported 5 million cycles without failure. The maximum load supported from each group after dynamic loading was recorded. The Spearman correlation and the Lowess method were used to analyze the correlation between the number of cycles and the applied load, and the Kruskal-Wallis and Nemenyi tests were used for comparison between the abutments when reaching 5 million cycles. Results: There was a negative correlation (r < 0.00) and significant difference (P < .05) between the number of cycles and the load for each type of implant and abutment. The load values supported by each group after cyclic loading to achieve 5 million cycles were as follows: EHS, 225 N; EHTi, 215 N; IH, 220 N; MT11.5, 210 N; and MT16, 240 N. The MT16 implant-abutment assembly presented a significantly higher load (P = .024) than the MT11.5 implant-abutment assembly. Conclusion: All implant-abutment connections investigated in this study resisted average occlusal force values reported as acceptable in the literature and may be indicated for any region of the mouth.
This split-mouth randomized controlled trial aimed to evaluate the primary and secondary stability of hybrid implants with different thread configurations and hydrophilic surfaces. Twenty patients with a partially edentulous maxilla were selected. These patients received two types of implants with the same hydrophilic surface: CTP group: Cylindrical-Tapered implant with perforating threads; CTH: Cylindrical-Tapered implant with hybrid threads configuration (perforating and condensing threads). The primary and secondary stability parameters were measured by insertion torque and resonance frequency analysis at the time of implant placement and 7, 28, 56, and 90 days after the surgical procedure. The paired t-test was used to compare the data on the implant's stability between the groups. The statistical analysis was performed with a confidence level set at 95%. It was found that the implants in the CTH group presented higher primary stability values at the time of implant placement, due to the higher ISQ (63.61 ± 9.44 vs. 40.59 ±7.46) and insertion torque (36.92 ± 16.50 Ncm vs. 28.00 ± 14.40 Ncm), than the implants in the CTP group. The CTH group presented higher ISQ values in all follow-up periods: 7 days (68.67 ± 7.60 vs. 41.55 ± 9.07), 28 days (68.61 ± 5.98 vs. 47.90 ±13.10), 56 days (74.09 ± 3.96 vs. 55.85 ± 13.18), and 90 days (75.45 ± 4.02 vs. 63.47 ± 6.92) after implant placement. Hybrid implants with perforating and condensing threads demonstrated greater stability than hybrid implants with only perforating threads.
The objective of this study is to examine the mechanical behavior of two-piece abutments (Morse taper with 16° internal angulation and Morse taper with 11.5° internal angulation) before and after cyclic fatigue testing, following ISO 14801:2016 guidelines. The specimens were divided into three groups: a modified Morse taper with a taper angle of 16° (GM group), a conventional Morse taper (taper angle of 11.5° deg) with a two-piece (CMt group), and one-piece abutments (CMo group). Each experimental group was formed by ten implants and ten abutments (n = 10) for a total of 30 specimens (n = 30). The abutments were tightened and loosened, and a fatigue test was applied with 15 Hz and 5 × 106 cycles. Subsequently, the abutments were loosened, and a pull-out test was performed on the CMt group. Finite element analysis (FEA) was conducted on stress concentration regions. The statistical analysis of the loosening test was performed using two-way ANOVA and Tukey’s tests (p < 0.05) to compare screw loosening within each group and between the groups with and without mechanical fatigue. Significant differences were found among the three groups in the loosening test when analyzing the values with and without fatigue (p < 0.001) within each group. When the groups were compared with each other, there was also a significant difference between them (p < 0.001), except between groups GM and CMt without fatigue (p = 0.840). In the pull-out test of the CMt group, the sample exhibited frictional locking only after fatigue (mean = 94.2 N). The FEA demonstrated a varied stress distribution in all groups. The stress was found to be more concentrated in the upper third and middle third regions of the implant, as well as in the opposite region of the load application for all three groups. Although the CMo group showed lower rates of loosening, it displayed a poorer stress distribution in comparison to the GM and CMt groups. On the other hand, the CMt group exhibited a satisfactory frictional lock after undergoing the fatigue tests.