Intake of hemoglobin by the hemoglobin-haptoglobin receptor CD163 leads to a distinct alternative non–foam cell antiinflammatory macrophage phenotype that was previously considered atheroprotective. Here, we reveal an unexpected but important pathogenic role for these macrophages in atherosclerosis. Using human atherosclerotic samples, cultured cells, and a mouse model of advanced atherosclerosis, we investigated the role of intraplaque hemorrhage on macrophage function with respect to angiogenesis, vascular permeability, inflammation, and plaque progression. In human atherosclerotic lesions, CD163+ macrophages were associated with plaque progression, microvascularity, and a high level of HIF1α and VEGF-A expression. We observed irregular vascular endothelial cadherin in intraplaque microvessels surrounded by CD163+ macrophages. Within these cells, activation of HIF1α via inhibition of prolyl hydroxylases promoted VEGF-mediated increases in intraplaque angiogenesis, vascular permeability, and inflammatory cell recruitment. CD163+ macrophages increased intraplaque endothelial VCAM expression and plaque inflammation. Subjects with homozygous minor alleles of the SNP rs7136716 had elevated microvessel density, increased expression of CD163 in ruptured coronary plaques, and a higher risk of myocardial infarction and coronary heart disease in population cohorts. Thus, our findings highlight a nonlipid-driven mechanism by which alternative macrophages promote plaque angiogenesis, leakiness, inflammation, and progression via the CD163/HIF1α/VEGF-A pathway.
Vascular calcification is routinely encountered in percutaneous coronary intervention (PCI) and severe coronary calcification is a known predictor of in-stent restenosis and stent thrombosis. However, the histopathologic mechanisms behind such events have not been systematically described. From our registry of 1211 stents, a total of 134 newer-generation drug-eluting stents (DES) (Xience, Resolute-Integrity, PROMUS-Element, and Synergy) with duration of implant ≥30 days were histologically analysed. The extent of calcification of the stented lesions was evaluated radiographically and divided into severe (SC, n = 46) and non-severely calcified lesions (NC, n = 88). The percent-uncovered struts per section {SC vs. NC; median 2.4 [interquartile range (IQR) 0.0–19.0] % vs. 0.0 (IQR 0.0–4.6) %, P = 0.02} and the presence of severe medial tears (MTs) (59% vs. 44%, respectively, P = 0.03) were greater in SC than NC. In addition, SC had a higher prevalence of ≥3 consecutive struts lying directly in contact with surface calcified area (3SC) (52% vs. 8%, respectively, P < 0.0001). Multivariate analysis demonstrated that sections with duration of implantation ≤6 months [odds ratio (OR): 7.7, P < 0.0001], 3SC (OR: 6.5, P < 0.0001), strut malapposition (OR: 5.0, P < 0.0001), and lack of MTs (OR: 2.5, P = 0.0005) were independent predictors of uncovered struts. Prevalence of neoatherosclerosis was significantly lower in SC than that of NC (24% vs. 44%, P = 0.02). Severe calcification, especially surface calcified area is an independent predictor of uncovered struts and delayed healing after newer-generation DES implantation. These data expand of knowledge of the vascular responses of stenting of calcified arteries and suggests further understand of how best to deal with calcification in patients undergoing PCI.
1 February 2025 in Circulation: Cardiovascular Interventions
BACKGROUND: Hypoattenuated leaflet thickening (HALT) is believed to reflect leaflet thrombosis; however, no systematic histological examination of HALT has ever been performed. The aim of this study was to evaluate histological findings of explanted self-expanding transcatheter aortic bioprosthetic valves from clinical trials and to compare microCT findings of suspected HALT with histology findings of valve thrombosis and its characterization over time. METHODS: A total of 123 self-expanding transcatheter aortic valves were collected through autopsy (n=89) or surgical explant (n=34) from 11 CoreValve/Evolut clinical trials. Histological findings in transcatheter aortic valve leaflets were evaluated. MicroCT imaging was used to evaluate HALT in histology. Cases with infective endocarditis (10/123) or transcatheter aortic valve-in-surgical aortic valve procedures (3/123) were excluded. RESULTS: A total of 110 cases were divided into 3 groups based on implant duration: 365 days (n=33). Thrombus and inflammation scores were consistent across groups, while scores for pannus, calcification, and structural change increased over time. The analysis of leaflet thickening by histology was performed on 320 leaflets and any degree of leaflet thickening was observed in 46.5% (149/320) of leaflets. Histologically, leaflet thickening was confirmed as an acute, organizing, and organized thrombus (ie, pannus). In the 30 days. The types of thrombi could not be differentiated by microCT imaging. CONCLUSIONS: HALT represents the presence of a thrombus and its progression. Our data suggest that treatment of HALT would likely be most effective in the early stages before the thrombus becomes organized and emphasizes the need for early detection.
The predominant substrate of high-intensity coronary plaque at MRI in stable coronary artery disease was intraplaque hemorrhage, not lipid. Background The histologic nature of coronary high-intensity plaques (HIPs) at T1-weighted MRI in patients with stable coronary artery disease remains to be fully understood. Coronary atherosclerosi...
Introduction: Polymers are an essential component of drug-eluting stents (DES) used to control drug release but remain the most controversial component of DES technology. There are two types of polymers employed in DES: durable polymer based DES (DP-DES) and biodegradable polymer DES (BP-DES). First-generation DES were exclusively composed of DP and demonstrated increased rates of late stent failure due in part to poor polymer biocompatibility. Newer generations DES use more biocompatible durable polymers or biodegradable polymers. Areas covered: We will cover issues identified with 1st-generation DP-DES, areas of success and failure in 2nd-generation DP-DES and examine the promise and shortcomings of BP-DES. Briefly, fluorinated polymers used in 2nd-generation DP-DES have excellent anti-thrombogenicity and better biocompatibility than 1st-generation DES polymers. However, these devices lead to persistent drug exposure to the endothelium which impairs endothelial function and predisposes towards neoatherosclerosis. Meanwhile, BP-DES has shortened the duration of drug exposure which might be beneficial for endothelial functional recovery leading to less neoatherosclerosis. However, it remains uncertain whether the long-term biocompatibility of bare metal surfaces is better than that of polymer-coated metals. Expert commentary: Each technology has distinct advantages, which can be optimized depending upon the particular characteristics of the patient being treated.