Alexander Ioffe

Prof. Dr. Alexander Ioffe

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 1998 in Physical Review A
Verified
Journal Article
Closed access
PDF file
AIAlexander Ioffe
Alexander Ioffe
DJD. L. Jacobson
D. L. Jacobson
MAM. Arif
M. Arif
MVM. Vrana
M. Vrana
SWS. A. Werner
S. A. Werner
FMF. Mezei
F. Mezei
The neutron-interferometry (NI) technique provides a precise and direct way to measure the bound, coherent scattering lengths b of low-energy neutrons in solids, liquids, or gases. The potential accuracy of NI to measure b has not been fully realized in past experiments, due to systematic sources of error. We have used a method which eliminates two of the main sources of error to measure the scattering length of silicon with a relative standard uncertainty of 0.005%. The resulting value, b=4.1507(2)fm, is in agreement with the current accepted value, but has an uncertainty five times smaller.

1 January 2018 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
JZJan Zaloga
Jan Zaloga
AFArtem Feoktystov
Artem Feoktystov
Vasil M. GaramusVasil M. Garamus
Vasil M. Garamus
WKWeronika Karawacka
Weronika Karawacka
AIAlexander Ioffe
Alexander Ioffe
SLStefan Lyer
Stefan Lyer

24 July 2014 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
ZSZ Salhi
Z Salhi
EBE Babcock
E Babcock
PPP Pistel
P Pistel
AIAlexander Ioffe
Alexander Ioffe

1 January 2013 in Physics Procedia
Verified
Journal Article
Open access
EBE. Babcock
E. Babcock
ZSZ. Salhi
Z. Salhi
MAM.-S. Appavou
M.-S. Appavou
AFA. Feoktystov
A. Feoktystov
VPV. Pipich
V. Pipich
AIAlexander Ioffe
Alexander Ioffe
In soft matter small angle neutron scattering (SANS) studies at large Q values, incoherent scattering becomes the dominant signal. In the Q-range of interest to this work, from 0.2 Å−1 to about 1.0 Å−1, the coherent scattering from the typical protein or polymer in a D2O buffer solution inevitably drops one to two orders of magnitude or more below the total scattering. Even after careful and accurate subtraction of the measured D2O buffer scattering, the remaining corrected, i.e. sample-only, signal will still be dominated by diffuse incoherent scattering from hydrogen in the sample itself. This is the exact region of interest when one wishes to probe the structural changes in “living” proteins caused by interactions and motions related to function. To further complicate the problem, there is strong motivation to measure this Q-regime at very low concentrations because it has been shown with wide angle X-ray scattering that proteins can undergo concentration-dependent structural changes that rapidly increase below concentrations of about 5% [1] motivating the study of protein solutions at ever lower concentrations. In this case the signal from the protein will inevitably become much less than the scattering of the D2O buffer solution it is contained in. Polarization analysis offers the opportunity to separate the weak coherent signal from the larger incoherent signal and perhaps enable measurements under the conditions described above. This paper will address the issues associated with the correct separation of coherent and incoherent scattering for soft matter samples. We have performed tests measurements on KWS2 which show the viability of the method on a protonated α-lactalbumin solution at 2.5% (1mm thick) and 0.25% (2mm thick) concentrations in a D2O buffer solution. Additionally describe a the method of implementation using 3He spin filters, some practical considerations, and future plans for a dedicated device at the JCNS

1 December 2002 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
AIAlexander Ioffe
Alexander Ioffe
MVM. Vrana
M. Vrana

18 January 1999 in Applied Physics Letters
Verified
Journal Article
Open access
WWW. E. Wallace
W. E. Wallace
DJD. L. Jacobson
D. L. Jacobson
MAM. Arif
M. Arif
AIAlexander Ioffe
Alexander Ioffe
The application of neutron interferometry to the measurement of the atom density of polymer thin films (<1 μm thick) supported on silicon substrates is described. Polymer films were chosen primarily for their fixed, well-defined stoichiometry; however, the technique is applicable to films of any elemental composition. The wavelength-independent phase shift of a beam of thermal neutrons passing through the sample gives a measure of the product of the film atom density, the film thickness, the lattice spacing of the silicon interferometer, and the scattering lengths of the constituent elements of the film. The film thickness was found by x-ray reflectivity while the other two parameters are well-defined quantities. The technique does not rely on complex mathematical modeling of physical processes nor on thin film standards for data interpretation. With some refinements, neutron interferometry is envisioned as an important tool in the creation of thin films having well-defined densities which will be useful in the calibration of many analysis techniques.