Konstantinos Papadopoulos

Dr. Konstantinos Papadopoulos

3rd Surgical Department, University General Hospital of Thessaloniki "AHEPA", Faculty of Health Sciences, School of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Konstantinos PapadopoulosKonstantinos Papadopoulos
Konstantinos Papadopoulos
ÖTÖzge Özden Tok
Özge Özden Tok
KMKonstantina Mitrousi
Konstantina Mitrousi
Ignatios IkonomidisIgnatios Ikonomidis
Ignatios Ikonomidis
A precise and accurate assessment of left ventricular (LV) contractility is of utmost importance in terms of prognosis in most cardiac pathologies. Given the limitations of ejection fraction (EF) and global longitudinal strain (GLS) due to their load dependency, a novel imaging tool called myocardial work (MW) has emerged as a promising method for LV performance evaluation. MW is a novel, less load-dependent method based on computation of myocardial strain–arterial blood pressure curves. This method provides a more detailed assessment of segmental and global LV function incorporating the patient’s LV pressure and is derived by brachial artery pressure utilizing an empiric reference curve adjusted to the duration of the isovolumic and ejection phases as determined by echocardiography. The clinical implications of this unique method have been expanding in the last few years, which attest to the robust additive role of MW in routine practice.

20 May 2020 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
Konstantinos PapadopoulosKonstantinos Papadopoulos
Konstantinos Papadopoulos
Ignatios IkonomidisIgnatios Ikonomidis
Ignatios Ikonomidis
MCMichael Chrissoheris
Michael Chrissoheris
ACAntonios Chalapas
Antonios Chalapas
PKPanagiota Kourkoveli
Panagiota Kourkoveli
KSKonstantinos Spargias
Konstantinos Spargias
Aims The purpose of this study is to identify echocardiography predictors of clinical response and reverse left ventricular (LV) remodelling in patients with functional mitral regurgitation (FMR) treated with MitraClip. Method and results We retrospectively analysed 86 high surgical risk patients with severe FMR; of those, 58 were implanted a MitraClip, and 28 received medical treatment and served as controls. At baseline and at 1‐year follow‐up, we performed clinical and echocardiography evaluation to assess global longitudinal strain (GLS) and myocardial work [global work index (GWI), global constructive work (GCW), global wasted work (GWW), global work efficiency (GWE)]. Mitral regurgitation was significantly reduced after MitraClip implantation (3.7 ± 0.4 vs. 1.7 ± 0.8, P < 0.001), and the procedure was associated with improvement in brain natriuretic peptide levels (980 ± 1027 vs. 420 ± 338 pg/mL, P < 0.001), New York Heart Association class status (3.2 ± 0.55 vs. 2.0 ± 0.6, P < 0.001), 6‐min walking test (233 ± 154 vs. 286 ± 114 m, P = 0.01) at follow‐up and reduction of left ventricle end‐systolic (LVESV) and left ventricle end‐diastolic volumes (LVEDV) (152 ± 68 vs. 136 ± 43 mL, P = 0.004 & 219 ± 74 vs. 193 ± 66 mL, P = 0.001, respectively). MitraClip procedure was associated with improvement of LV performance and significant increase of GWI (607 ± 282 vs. 650 ± 260 mmHg%, P = 0.045) and GCW (854 ± 288 vs. 949 ± 325 mmHg%, P < 0.001). Baseline ejection fraction (EF), GLS, GWI, GCW, and effective regurgitant orifice area were the variables that were associated with reduction of LVEDV 1 year after intervention (P < 0.05 for all) and baseline GCW of the LV was the only variable associated with reduction of LVESV (P = 0.002). Receiver operating characteristic curve analysis identified that a GLS cut‐off value of −8.65% (AUC 0.815, P = 0.007) was associated with a 20% reduction of the LVEDV with a sensitivity and specificity of 72% and 70%, respectively, and that a GCW cut‐off value of 846 mmHg% (AUC 0.759, P = 0.007) was associated with a 10% reduction of LVESV with sensitivity and specificity 79% and 74%, respectively. Conclusions Mitral valve repair with MitraClip has positive clinical and echocardiographic impact in patients with FMR 1 year after implantation. Preserved GLS and GCW values appear to be associated with LV reverse remodelling post intervention.

6 February 2019 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
Konstantinos PapadopoulosKonstantinos Papadopoulos
Konstantinos Papadopoulos
MCMichael Chrissoheris
Michael Chrissoheris
INIoulia Nikolaou
Ioulia Nikolaou
KSKonstantinos Spargias
Konstantinos Spargias
Background Papillary muscle (PM) rupture is a devastating mechanical complication of myocardial infarction that leads to cardio-genic shock and death. In this case, we report a patient with acute mitral regurgitation due to PM rupture that was treated successfully with MitraClip. Case summary An 85-year-old female patient with anterior ST-elevation myocardial infarction complicated with PM rupture and acute severe mitral regurgitation was admitted to our hospital. The patient's surgical risk was considered to be prohibitively high, and was therefore, referred for transcatheter edge-to-edge repair with MitraClip. The procedure was successful, and the patient was discharged home in a stable condition. Discussion Acute mitral regurgitation due to PM rupture is a mechanical complication of myocardial infarction that should be treated early because of high mortality rates. This case highlights the role of MitraClip in acute mitral regurgitation and acute heart failure as an alternative to surgery method in high-risk patients.

16 October 2020 in Echocardiography
Verified
Journal Article
Closed access
PDF file
SÜserkan ünlü
serkan ünlü
ÖTÖzge Özden Tok
Özge Özden Tok
FDFulya Avcı Demir
Fulya Avcı Demir
Konstantinos PapadopoulosKonstantinos Papadopoulos
Konstantinos Papadopoulos
MMMark J. Monaghan
Mark J. Monaghan

28 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Konstantinos PapadopoulosKonstantinos Papadopoulos
Konstantinos Papadopoulos
Ignatios IkonomidisIgnatios Ikonomidis
Ignatios Ikonomidis
ACAugustin Coisne
Augustin Coisne
ÖKÖzge Özden Kayhan
Özge Özden Kayhan
ATApostolos Tzikas
Apostolos Tzikas
EDErwan Donal
Erwan Donal
Background: Transesophageal echocardiography (TEE) is a vital diagnostic tool in clinical practice, particularly in transcatheter interventions where it aids in both pre-operative planning and intra-operative guidance. Traditional TEE probes often require general anesthesia due to patient discomfort. However, the development of miniaturized TEE probes presents a promising alternative, enabling routine examinations and interventions with minimal sedation. This study evaluates the feasibility of performing a complete 2D/4D TEE protocol with the new 4D mini-TEE probe in the echocardiography department and its application in transcatheter interventions. Methods: This is a retrospective study that included 30 consecutive patients from two high-volume European hospitals (Interbalkan Medical Center, Thessaloniki, Greece, and Rennes University, France) that underwent TEE or transcatheter interventions. The new 4D mini-TEE 9VT-D probe (GE Healthcare) was utilized. The quality of the images and the tolerance of the probe were assessed in the cath lab during interventions and in the echocardiography department during routine TEE examinations. Results: Direct comparison of the 4D mini-TEE probe with the standard 6VT-D probe confirmed the excellent image quality of this new pediatric probe. Most of the patients required minimal sedation or local oropharyngeal anesthesia, with satisfactory tolerance reported. Most of the transcatheter procedures did not require general anesthesia and intubation, resulting in shorter procedural time. Both 2D and 4D imaging modalities offered adequate intra-operative guidance for transcatheter procedures. Conclusions: The 4D mini-TEE probe delivers exceptional imaging capabilities for routine examinations and transcatheter interventions without needing sedation. Its use reduces esophageal trauma and the need for general anesthesia, enhancing patient comfort and safety.

1 November 2020 in Hellenic Journal of Cardiology
Verified
Journal Article
Open access
George NtaiosGeorge Ntaios
George Ntaios
ATApostolos Tzikas
Apostolos Tzikas
EVEmmanouil Vavouranakis
Emmanouil Vavouranakis
DNDimitrios Nikas
Dimitrios Nikas
GKGeorgios Katsimagklis
Georgios Katsimagklis
KTKonstantinos Tsioufis
Konstantinos Tsioufis