Yeo-Kyung Lee

Ms. Yeo-Kyung Lee

Department of Architectural Engineering, Graduate School, Seoul National University of Science and Technology, Seoul 01811, Korea
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Korean Diabetes Journal
Verified
Journal Article
Open access
PDF file
KKKyung-Soo Kim
Kyung-Soo Kim
HOHyunju Oh
Hyunju Oh
Ji-woon KimJi-woon Kim
Ji-woon Kim
YLYeo-Kyung Lee
Yeo-Kyung Lee
SKSoo-Kyung Kim
Soo-Kyung Kim
YCYong-Wook Cho
Yong-Wook Cho
Kim KS, et al. Korean Diabetes J. 2010 Apr;34(2):119-125. https://doi.org/10.4093/kdj.2010.34.2.119

29 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
YLYeo-Kyung Lee
Yeo-Kyung Lee
YKYoung Il Kim
Young Il Kim
Owing to the recent increase in the number of warning reports and alerts on the dangers of fine dusts, there has been an increasing concern over fine dusts among citizens. In spaces with poor ventilation, the occupants are forced to open the window to initiate natural ventilation via the direct introduction of the outside air; however, this may pose a serious challenge if the external fine-dust concentration is high. The lack of natural ventilation increases the indoor carbon dioxide (CO2) concentration, thus necessitating the installation of mechanical ventilation systems. This study analyzed the frequency of the application of mechanical ventilation systems in the Multi-purpose activity space of elementary schools, which are spaces where children require a higher indoor air quality than adults owing to the rapid increase in the CO2 concentration of the Multi-purpose activity space during activities. In addition, the architectural and equipment factors of the Multi-purpose activity spaces of nine elementary schools were characterized. The results revealed that five out of the nine elementary schools installed mechanical ventilation systems, whereas the remaining four schools installed jet air turnover systems. The indoor air quality of the Multi-purpose activity space of D elementary school, which had the minimum facility volume among the schools investigated in this study (564.2 m3), with up to 32 participants for each activity, was investigated. The results revealed that the ultrafine-dust (PM2.5) concentration of the facility was as high as 4.75 µg/m3 at a height of 1.2 m, and the CO2 concentration was as high as 3183 ppm. The results of the analysis of three elementary schools with different volumes were compared and analyzed using CONTAM simulation. This study determined the required volume per occupant and the optimum number of occupants for a given volume and presented guidelines for the optimum number of occupants, activities, and volume to reduce the high concentration of pollutants in the analyzed Multi-purpose activity space. The guideline proposed in this study is aimed at maintaining the CO2 concentration of the Multi-purpose activity space below 1000 ppm, as prescribed by the Indoor Air Quality Control in Public-Use Facilities, Etc. Act in South Korea.

28 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
YLYeo-Kyung Lee
Yeo-Kyung Lee
YKYoung Il Kim
Young Il Kim
WLWoo-Seok Lee
Woo-Seok Lee
Ventilation is becoming increasingly important to improve indoor air quality and prevent the spread of COVID-19. This study analyzed the indoor air quality of office spaces, where occupants remain for extended periods, among multi-use facilities with an increasing need for ventilation system application. A “tool for office space CO2 prediction and indoor air quality improvement recommendation” was developed. The research method was divided into four steps. Step 1: Analysis of indoor air quality characteristics in office spaces was carried out with a questionnaire survey and indoor air quality experiment. Based on the CO2 concentration, which was found to be a problem in the indoor air quality experiment in the office space, Step 2: CO2 concentration prediction tool for office spaces, which requires inputs of regional and spatial factors and architectural and equipment elements, was developed. In Step 3: Development and verification of prediction tool considering economic feasibility, the cost of energy recovery ventilation systems based on the invoices of the energy recovery ventilation manufacturers was analyzed. In Step 4: Energy recovery ventilation proposal and indoor CO2 forecast, Office Space B, which can accommodate up to 15 people, was derived as an example of the proposed tool. As a result of the prediction, the optimal air volume of the energy recovery ventilation was determined according to the “office CO2 prediction and indoor air quality improvement recommendations”. This study introduced simple tools, which can be used by non-experts, that are capable of showing changes in indoor air quality, CO2 concentration and cost according to activities.

31 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
YLYeo-Kyung Lee
Yeo-Kyung Lee
YKYoung Il Kim
Young Il Kim
GKGa-Hyeon Kim
Ga-Hyeon Kim
This study presents a simple indoor air quality diagnosis program for school office spaces, which are occupied for long durations by teachers, and indoor sports facilities, whose utilization has been on the rise in response to high concentrations of pollutants in outdoor air. The proposed program was made with Visual Basic for Applications (VBA) and Microsoft Excel. This program requires inputs which can be easily determined or measured even by nonexperts and can check the current status of indoor air quality such as CO2 and PM2.5 concentrations and predict the effect if changes are made. In addition, it is possible to diagnose indoor air quality before and after class and compare it with the initial plan so that if it exceeds the indoor air quality maintenance standard range, it can be improved by using a ventilation system and an air purifier. The development of the program was divided into four stages. First, prior research on the influencing factors was investigated. Second, influencing factors affecting the changes in PM2.5 and CO2 concentrations were selected by category to accommodate the various factors, and those selected as input were presented. Third, mass and concentration conservation equations were utilized to derive PM2.5 and CO2 concentration prediction equations according to activity and passage of time, and a VBA code was used for constructing the program. For verification of the developed program, the calculation results were compared with the measured data. The mean absolute percentage error (MAPE) was 19.47% for PM2.5 concentration. In order to improve accuracy, Simulation 2, in which the wind speed and indoor/outdoor air pressure difference are corrected, is presented. The MAPE of PM2.5 concentration by the corrected Simulation 2 was lowered 5.15%.