Modular hip joint implants were introduced in arthroplasty medical procedures because they facilitate the tailoring of patients’ anatomy, the use of different materials in one single configuration, as well as medical revision. However, in certain cases, such prostheses may undergo deterioration at the head–neck junctions with negative clinical consequences. Crevice-corrosion is commonly invoked as one of the degradation mechanisms acting at those junctions despite biomedical alloys such as Ti6Al4V and CoCr being considered generally resistant to this form of corrosion. To verify the occurrence of crevice corrosion in modular hip joint junctions, laboratory crevice-corrosion tests were conducted in this work under hip joint-relevant conditions, i.e., using similar convergent crevice geometries, materials (Ti6Al4V and CoCr alloys vs. ceramic), surface finish, NaCl solution pHs (5.6 and 2.3), and electrochemical conditions. A theoretical model was also developed to describe crevice-corrosion considering relevant geometrical and electrochemical parameters. To verify the model, a FeCr alloy, known to be sensitive to this phenomenon, was subjected to the crevice-corrosion test in sulfuric acid. The experiments and the model predictions clearly showed that, in principle, crevice corrosion of Ti6Al4V or CoCr is not supposed to occur in typical crevices formed at the stem-neck junction of hip implants.
Objetivo: evaluar la resistencia a la corrosión de las boquillas de inyección de acero inoxidable bajo ensayo de inmersión en biodiésel, y realizar una caracterización electroquímica bajo soluciones de HNO3. Métodos y materiales: Se realizó la caracterización química del biodiésel para analizar su estabilidad. Se realizaron pruebas de inmersión durante 4 meses, evaluando el acero inoxidable 304 bajo 3 concentraciones diferentes de mezclas de diésel/biocombustible. Además, se realizaron ensayos de polarización con concentraciones de NOx superiores a los niveles medidos en las emisiones de los motores. Resultados y discusión: El uso de biocombustibles en Colombia ha sido impulsado en gran medida por la producción de etanol de origen vegetal. Su uso aporta algunas ventajas relacionadas con la reducción de las emisiones de partículas y gases tóxicos (principalmente, grupos aromáticos, NOx y CO2). Sin embargo, puede producirse una degradación de los materiales cuando están en contacto directo con el biodiésel. Además, se ha informado de solidificación de ceras, que provoca el taponamiento de las boquillas. No obstante, se desconoce si esto influye en la difusión del oxígeno en la solución y, a su vez, afecta a la resistencia a la corrosión del acero inoxidable. Conclusiones: La resistencia a la corrosión del acero inoxidable 304 cambió bajo condiciones de inmersión, aunque su capa protectora no se vio afectada por las concentraciones de NOx registradas en las mezclas de biocombustible.
23 March 2021 in Revista Facultad de Ingeniería Universidad de Antioquia
The introduction of modular design in total hip arthroplasty has enabled the use of different materials in one single configuration and the adjustment of the prosthesis to the patient’s body, and facilitated medical revisions. However, modularity leads to the presence of new interfaces created between pieces in contact, raising the issue of degradation. Tribocorrosion phenomena have been identified as the main degradation mechanism due to the mechanical, chemical, and electrochemical conditions acting on the materials. In addition, conditions inside the human body are unclear, regarding electrochemical settings and the interaction between the electrochemical and mechanical action. This work is focused on the degradation of monopolar hip joint implants made from biomedical alloys such as stainless steel, Ti, and CoCr alloys. Three cases are presented and analyzed in terms of the degradation level along the trunnion length. Surface analysis done on a titanium trunnion showed a significant ploughing on the distal part, compared to what was found for stainless Steel and cobalt-chromium alloys, which can produce a stuck in this area. Meanwhile, in the proximal part, wear debris is found, which suggests more movement in the internal part. Although few debris particles were identified in CoCr trunnion, a large amount of material inside the contact was observed. This could be related to the ploughing generated in the distal thread pattern, which allowed the material to come inside and outside the contact.
Nanostructured TiO₂ coatings, have shown promise in improving implant performance by enhancing antibacterial properties and promoting specific biological responses, including osteoblast proliferation. Surface characteristics such as wettability, chemical composition, and crystallinity play a critical role in modulating cellular behaviour. Inspired by natural antimicrobial surfaces, nanostructured surfaces with needle-like features have emerged as an effective strategy to inhibit bacterial adhesion while promoting mammalian cell growth.This study investigates the formation of TixOy nanospikes on Ti-6Al-4V alloy surfaces through a two-stage process involving acetone pyrolysis followed by high-temperature oxidation. The research focuses on characterizing the phase composition, morphology, and crystallographic orientation of these nanospikes by XRD, FESEM, and TEM analysis.The main results showed that the nanoscale coating is composed of a multi-phase oxide structure formed of TiO₂-rutile, Ti₆O, and Ti₃O₅. Several preferred orientations were found. TiO₂-rutile adopted a prismatic morphology along the [001] axis, and Ti₆O growth aligned with the [110] direction. The unique morphology and phase composition of these titanium oxide nanospikes hold significant promise for future biomedical applications.
Nanostructured TiO₂ coatings, have shown promise in improving implant performance by enhancing antibacterial properties and promoting specific biological responses, including osteoblast proliferation. Surface characteristics such as wettability, chemical composition, and crystallinity play a critical role in modulating cellular behaviour. Inspired by natural antimicrobial surfaces, nanostructured surfaces with needle-like features have emerged as an effective strategy to inhibit bacterial adhesion while promoting mammalian cell growth. This study investigates the formation of TixOy nanospikes on Ti-6Al-4V alloy surfaces through a two-stage process involving acetone pyrolysis followed by high-temperature oxidation. The research focuses on characterizing the phase composition, morphology, and crystallographic orientation of these nanospikes by XRD, FESEM, and TEM analysis. The main results showed that the nanoscale coating is composed of a multi-phase oxide structure formed of TiO₂-rutile, Ti₆O, and Ti₃O₅. Several preferred orientations were found. TiO₂-rutile adopted a prismatic morphology along the [001] axis, and Ti₆O growth aligned with the [110] direction. The unique morphology and phase composition of these titanium oxide nanospikes hold significant promise for future biomedical applications.