Background: The ankle brachial index (ABI) is widely used in clinical practice as a non‐invasive method to detect the presence and severity of peripheral arterial disease (PAD). Current guidelines suggest that it should be used to monitor potential progression of PAD in affected individuals. As such, it is important that the test is reliable when used for repeated measurements, by the same or different health practitioners. This systematic review aims to examine the literature to evaluate the inter‐ and intra‐rater reliability of the ABI.Methods: A systematic search of MEDLINE, EMBASE and CINAHL Complete was conducted to 20 January 2019. Two authors independently reviewed and selected relevant studies and extracted the data. Methodological quality was determined using the Quality Appraisal of Reliability (QAREL) Checklist.Results: Fifteen studies of ABI reliability in a range of patient populations were identified as suitable for inclusion in the review: seven considered inter‐rater reliability, four intra‐rater reliability, and four studies evaluated both inter‐ and intra‐rater reliability. Inter‐rater reliability was found to be highly variable, with intraclass correlation coefficients (ICC's) ranging from poor to excellent (ICC 0.42–1.00), while intra‐rater also demonstrated considerable variation, with ICCs from 0.42–0.98. Meta‐analysis was not possible due to the lack of statistical information reported.Conclusions: Results of included studies suggest the inter‐ and intra‐tester reliability of the ABI is acceptable. However, inconsistencies in obtaining systolic pressure measurements, calculating ABI values, and incomplete reporting of methodologies and statistical analysis make it difficult to determine the validity of the results of included studies. Further research, with more consistent reliability methodology, statistical analysis and reporting conducted in populations at risk of PAD is needed to conclusively determine the ABI reliability.
24 December 2021 in BMJ Open Diabetes Research & Care
The objective is to determine, by systematic review, the reliability of testing methods for diagnosis of diabetes-related peripheral neuropathy (DPN) as recommended by the most recent guidelines from the International Diabetes Foundation, International Working Group on the Diabetic Foot and American Diabetes Association. Electronic searches of Cochrane Library, EBSCO Megafile Ultimate and EMBASE were performed to May 2021. Articles were included if they reported on the reliability of recommended chairside tests in diabetes cohorts. Quality appraisal was performed using a Quality Appraisal of Reliability Studies checklist and where possible, meta-analyses, with reliability reported as estimated Cohen’s kappa (95% CI). Seventeen studies were eligible for inclusion. Pooled analysis found acceptable inter-rater reliability of vibration perception threshold (VPT) (κ=0.61 (0.50 to 0.73)) and ankle reflex testing (κ=0.60 (0.55 to 0.64)), but weak inter-rater reliability for pinprick (κ=0.45 (0.22 to 0.69)) and 128 Hz tuning fork (κ=0.42 (0.15 to 0.70)), though intra-rater reliability of the 128 Hz tuning fork was moderate (κ=0.54 (0.37 to 0.73)). Inter-rater reliability of the four-site monofilament was acceptable (κ=0.61 (0.45 to 0.77)). These results support the clinical use of VPT, ankle reflexes and four-site monofilament for screening and ongoing monitoring of DPN as recommended by the latest guidelines. The reliability of temperature perception, pinprick, proprioception, three-site monofilament and Ipswich touch test when performed in people with diabetes remains unclear.
1 February 2017 in Journal of Science and Medicine in Sport
Background: Testing of protective sensation and vibration perception are two of the most commonly used non‐invasive methods of screening for diabetes‐related peripheral neuropathy (DPN). However, there is limited research investigating the reliability of these tests in people with diabetes. The aim of this study was to determine the inter‐ and intra‐rater reliability of methods used to test vibration perception and protective sensation in a community‐based population of adults with type 2 diabetes.Methods: Three podiatrists with varying clinical experience tested four‐ and 10‐site, 10 g monofilament and vibration perception threshold (VPT). In a separate cohort, the reliability of a graduated tuning fork as well as two methods of conventional tuning fork (on/off method and dampening method) was undertaken by a new graduate podiatrist and podiatrist with one‐year's clinical experience. The intra‐ (Cohen's К) and inter‐rater (Cohen's or Fleiss' К) reliability of each test was determined.Results: Fifty participants (66% male, 100% type 2, 32% with DPN) underwent monofilament and neurothesiometer testing with 44 returning for the retest. Twenty‐four participants (63% male, 100% type 2, 4% with DPN) underwent tuning fork testing and returned for retest. All tests demonstrated acceptable inter‐rater reliability ranging from moderate (10‐site monofilament, К: 0.54, CI: 0.38–0.70, p = 0.02) to substantial (graduated tuning fork, К: 0.68, CI: 0.41–0.95, p < 0.01). The 10‐site monofilament (К: 0.44–0.77) outperformed the 4‐site test (К: 0.34–0.67) and the dampened tuning fork method (К: 0.41–0.49) showed lower intra‐rater reliability compared to both conventional (К: 0.52–0.57) and graduated methods (К: 0.50–0.57).Conclusion: We support the current recommendations of using more than one test to screen and monitor progression of DPN. Four‐ and 10‐site 10 g monofilament testing have similarly acceptable levels of reliability and the neurothesiometer is the most reliable method of assessing vibration perception function. Use of a graduated tuning fork was slightly more reliable than other methods of tuning fork application however all had substantial reliability. Years of clinical experience only marginally affected test reliability overall and due to subjective nature of the tests we suggest that testing should be performed regularly and repetitively.
1 January 2020 in Journal of Foot and Ankle Research
Background: The ankle‐brachial index (ABI) is widely used for determining the presence and severity of peripheral arterial disease (PAD), and current guidelines suggest it should be used to monitor possible progression in affected individuals. It is therefore important that the technique demonstrates adequate reliability for repeated measurements. Existing studies suggest that the ABI is reliable in the general population however, there is a lack of evidence for the reliability of the ABI in people with diabetes. The aim of this study was to investigate the intra‐tester reliability of the ABI in people with and without diabetes.Methods: Eighty‐five participants (40 with and 45 without diabetes) underwent ankle and brachial systolic blood pressure measurements by a single clinician during two testing sessions. Intraclass correlation coefficients (ICC), their 95% limits of agreement, standard error of measurement and minimal detectable change were determined.Results: Intra‐tester reliability of the ABI was found to be good (ICC: 0.80), however sub‐group analysis of participants with and without diabetes found that ABI was slightly less reliable in people with diabetes (ICC: 0.78) than in those without (ICC: 0.82). The relatively large limits of agreement (− 0.16 to 0.16), standard error of measurement (0.03 overall, 0.04 for the diabetes group), and minimal detectable change (0.08 overall, 0.11 for the diabetes group) suggest that a large change in ABI is required for it to demonstrate a true change rather than the result of measurement variability. The minimal detectable change for the ABI was 0.08 overall, and 0.11 for the diabetes group.Conclusions: The ABI demonstrated good reliability in all groups analysed. However, the wide limits of agreement and considerable standard error of measurement obtained support the use of multiple methods of vascular assessment for ongoing monitoring of lower limb vascular status.