Federica Costa

Mrs. Federica Costa

University of Bologna
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Alessandro MingottiAlessandro Mingotti
Alessandro Mingotti
FCFederica Costa
Federica Costa
GPGaetano Pasini
Gaetano Pasini
Lorenzo PerettoLorenzo Peretto
Lorenzo Peretto
ROBERTO TINARELLIROBERTO TINARELLI
ROBERTO TINARELLI
The use of capacitive dividers (CDs) in medium-voltage (MV) networks started as simple voltage detectors and as rough voltage measurement instruments for protective purposes. Now, with the spread of intelligent electronic devices and renewable energy sources at the distribution level, capacitive dividers are designed and installed to perform accurate voltage measurements. Such a requirement is mandatory when the power quality has to be assessed. Therefore, CDs are currently being used either for power frequency or for high-frequency (supraharmonic- or partial-discharge-level) measurements. In this paper, typical off-the-shelf CDs are studied and modeled to understand how they behave in a wide range of frequencies and when the temperature varies. To this purpose, specific setups and tests have been developed and performed. From the results, it is clear that with proper modeling of CDs, it is possible to exploit them for measuring phenomena in a wide range of frequencies, including the effects due to temperature variations and self-resonances.

11 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Alessandro MingottiAlessandro Mingotti
Alessandro Mingotti
FCFederica Costa
Federica Costa
Lorenzo PerettoLorenzo Peretto
Lorenzo Peretto
ROBERTO TINARELLIROBERTO TINARELLI
ROBERTO TINARELLI
Low-Power Instrument Transformers (LPITs) are becoming the first choice for distributed measurement systems for medium voltage networks. However, there are still a lot of challenges related to their operation. Such challenges include their accuracy variation when several influence quantities are acting on them. Among the most significant influence quantities are temperature, electromagnetic field, humidity, etc. Another aspect that increases the importance of studying the LPITs’ accuracy behavior is that, once installed, they cannot be calibrated for several years; hence, one cannot compensate for in-field conditions. Hence, this work aims at introducing a simple type test for a specific LPIT, the Rogowski coil. First, an experimental setup to assess the effect of temperature, humidity, and positioning on the power quality accuracy performance of the Rogowski coil is described. Second, from the results and the experience of the authors it has been possible to design a specific type test. The test has the aim of finding the limits of the accuracy variations of a single Rogowski coil. Afterwards, such limits can be used to compensate for the in-field measurements, obtaining an overall higher accuracy. The results of this work may contribute to the always-evolving standardization work on LPITs.

13 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Alessandro MingottiAlessandro Mingotti
Alessandro Mingotti
FCFederica Costa
Federica Costa
DCDiego Cavaliere
Diego Cavaliere
Lorenzo PerettoLorenzo Peretto
Lorenzo Peretto
ROBERTO TINARELLIROBERTO TINARELLI
ROBERTO TINARELLI
In recent years, the introduction of real-time simulators (RTS) has changed the way of researching the power network. In particular, researchers and system operators (SOs) are now capable of simulating the complete network and of making it interact with the real world thanks to the hardware-in-the-loop (HIL) and digital twin (DT) concepts. Such tools create infinite scenarios in which the network can be tested and virtually monitored to, for example, predict and avoid faults or energy shortages. Furthermore, the real-time monitoring of the network allows estimating the status of the electrical assets and consequently undertake their predictive maintenance. The success of the HIL and DT application relies on the fact that the simulated network elements (cables, generation, accessories, converters, etc.) are correctly modeled and characterized. This is particularly true if the RTS acquisition capabilities are used to enable the HIL and the DT. To this purpose, this work aims at emphasizing the role of a preliminary characterization of the virtual elements inside the RTS system, experimentally verifying how the overall performance is significantly affected by them. To this purpose, a virtual phasor measurement unit (PMU) is tested and characterized to understand its uncertainty contribution. To achieve that, firstly, the characterization of a virtual PMU calibrator is described. Afterward, the virtual PMU calibration is performed, and the results clearly highlight its key role in the overall uncertainty. It is then possible to conclude that the characterization of the virtual elements, or models, inside RTS systems (omitted most of the time) is fundamental to avoid wrong results. The same concepts can be extended to all those fields that exploit HIL and DT capabilities.

5 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Alessandro MingottiAlessandro Mingotti
Alessandro Mingotti
FCFederica Costa
Federica Costa
Lorenzo PerettoLorenzo Peretto
Lorenzo Peretto
ROBERTO TINARELLIROBERTO TINARELLI
ROBERTO TINARELLI
Power quality evaluation is the process of assessing the actual power network parameters with respect to the ideal conditions. However, several new assets and devices among the grid include mining the voltage and current quality. For example, the power converters needed for renewable energy sources’ connection to the grid, electric vehicles, etc., are some of the main sources of disturbances that inject high-frequency components into the grid. Consequently, instrument transformers (ITs) should be capable of measuring distorted currents and voltages with the same level of accuracy guaranteed for the ideal frequency (50–60 Hz). This is not a simple task if one considers that several other influence quantities endlessly act on the ITs. To this purpose, considering the lack of a standard, this work presents a measurement setup and specific tests for testing a commonly used type of low-power current transformer, the Rogowski coil (RC). In particular, the accuracy performance (ratio error and phase displacement) of the RCs was evaluated when measuring distorted signals while other influence quantities affected the RCs. Such quantities included positioning, burden, and magnetic field. The results indicate which quantities (or combination of them) have the greatest effect on the RC’s accuracy performance.

25 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
Alessandro MingottiAlessandro Mingotti
Alessandro Mingotti
FCFederica Costa
Federica Costa
Lorenzo PerettoLorenzo Peretto
Lorenzo Peretto
ROBERTO TINARELLIROBERTO TINARELLI
ROBERTO TINARELLI
PMPaolo Mazza
Paolo Mazza
Stray capacitances (SCs) are a serious issue in high-voltage (HV) applications. Their presence can alter the circuit or the operation of a device, resulting in wrong or even disastrous consequences. To this purpose, in this work, we describe the modeling of SCs in HV capacitive dividers. Such modeling does not rely on finite element analysis or complicated geometries; instead, it starts from an equivalent circuit of a conventional measurement setup described by the standard IEC 61869-11. Once the equivalent model including the SCs is found, closed expressions of the SCs are derived starting from the ratio error definition. Afterwards, they are validated in a simulation environment by implementing various circuit configurations. The results demonstrate the expressions applicability and effectiveness; hence, thanks to their simplicity, they can be implemented by system operators, researchers, and manufacturers avoiding the use of complicated methods and technologies.

29 September 2021
Verified
Conference Paper
Closed access
AMAlessandro Mingotti
Alessandro Mingotti
FCFederica Costa
Federica Costa
LPLorenzo Peretto
Lorenzo Peretto
RTRoberto Tinarelli
Roberto Tinarelli
The power quality (PQ) problem is spreading among the distribution network (DN) since intelligent electronic devices (IED) are being installed. Their presence is crucial because they introduce several benefits for the network observability and management. However, the consequent power quality degradation has to be seriously tackled. To this purpose, measurement instruments should be capable of measuring the electrical quantities even in presence of distortion. Furthermore, the new added distortion has to be summed to the typical influence factors affecting the measurement instruments (like temperature, electromagnetic fields, humidity, etc.). Therefore, this paper presents a study on a specific low-power current transformer (LPCT), the Rogowski coil. In detail, the influence of external magnetic fields, on the Rogowski accuracy performance, is evaluated when the device is measuring distorted signals (with an increasing level of distortion). The aim is to study the combined effect of the magnetic fields and of the distorted currents on the measurement performance of a Rogowski coil. Therefore, an ad-hoc measurement setup and tests are developed in this work to assess 3 off-the-shelf Rogowski coils. From the results it can be concluded that the presence of external magnetic fields does not influence the harmonics evaluation, but it does influence the evaluation of the 50 Hz component.