Auburn University

Dr. Auburn University

Auburn University
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Yuzhe SunYuzhe Sun
Yuzhe Sun
AUAuburn University
Auburn University
To achieve the promise of stimuli-responsive drug delivery systems for the treatment of cancer, they should (1) avoid premature clearance; (2) accumulate in tumors and undergo endocytosis by cancer cells; and (3) exhibit appropriate stimuli-responsive release of the payload. It is challenging to address all of these requirements simultaneously. However, the numerous proof-of-concept studies addressing one or more of these requirements reported every year have dramatically expanded the toolbox available for the design of drug delivery systems. This review highlights recent advances in the targeting and stimuli-responsiveness of drug delivery systems. It begins with a discussion of nanocarrier types and an overview of the factors influencing nanocarrier biodistribution. On-demand release strategies and their application to each type of nanocarrier are reviewed, including both endogenous and exogenous stimuli. Recent developments in stimuli-responsive targeting strategies are also discussed. The remaining challenges and prospective solutions in the field are discussed throughout the review, which is intended to assist researchers in overcoming interdisciplinary knowledge barriers and increase the speed of development. This review presents a nanocarrier-based drug delivery systems toolbox that enables the application of techniques across platforms and inspires researchers with interdisciplinary information to boost the development of multifunctional therapeutic nanoplatforms for cancer therapy.

1 October 2010 in Journal of Nanoscience and Nanotechnology
Verified
Journal Article
Closed access
CWChristopherJ. Ward
ChristopherJ. Ward
Shang SongShang Song
Shang Song
AUAuburn University
Auburn University
The first direct comparison between two common methods for loading halloysite with a small molecule for controlled release is presented. While the methods differ in the degree of simplicity, they provide essentially the same level of loading and release kinetics. A tentative explanation of the "burst" effect often seen in the release of low molecular weight molecules from halloysite is provided. The ability of halloysite to mediate the release rate of a water soluble drug, tetracycline, from solution cast polyvinyl alcohol and polymethyl methacrylate films was evaluated. In some films, montmorillonite was also incorporated. The addition of montmorillonite to solutions used to cast tetracycline containing films significantly reduced the release rate from the dried films. The same overall effect was seen when the drug was loaded into halloysite prior to preparation of the films. In both cases, the release was best fit with the simple Higuchi model. However, when montmorillonite was added to solutions of polyvinyl alcohol and drug loaded halloysite the release profiles were better fit by the Ritgar-Peppas model for anomalous transport. Release from polymethyl methacrylate was reduced by a factor of three by incorporating the drug in halloysite prior to producing the films.

1 January 2014 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
CWChristopher J. Ward
Christopher J. Ward
RTRobert Tronndorf
Robert Tronndorf
AEAlicia S. Eustes
Alicia S. Eustes
Maria L AuadMaria L Auad
Maria L Auad
AUAuburn University
Auburn University
The effects of the seed reaction conditions on the two‐step seed‐mediated growth of gold nanorods and the effect of gold and reducing agent content in the growth solution were evaluated. Results indicate that the reaction conditions used to produce the seeds have a significant impact on the aspect ratio of the gold nanorods produced. Increasing the concentration of gold or the reaction temperature in the seed production step results in lower length to diameter (aspect ratio) gold rods. In addition, the amount of prepared seed added to the growth solution impacts the rod aspect ratio, with increasing amounts of seed reducing the aspect ratio. The effects of reducing agent, ascorbic acid (AA), and gold content of the growth solution on the aspect ratio of the produced rods are strongly interrelated. There exists a minimum ascorbic acid to gold concentration below which rods will not form; however, increasing the ratio above this minimum results in shorter rods being formed. Characterization of nanorod growth is performed by UV‐vis‐NIR spectrophotometry and transmission electron microscopy (TEM).

7 October 2019 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
Yuzhe SunYuzhe Sun
Yuzhe Sun
AUAuburn University
Auburn University
We report a novel synthesis scheme to produce polydopamine (PDA) nanotubes using halloysite clay nanotubes (HNT) as a sacrificial template. Polydopamine nanotubes were fabricated via the formation of a polydopamine coating on HNT from a dopamine solution followed by template removal. Michael Addition was used to decorate the outer surface with polyethylene glycol. Removal of the template material resulted in a bilayered organic nanotube consisting of an inner layer of polydopamine adjacent to the lumen and an outer polyethylene glycol surface. The tubes had an aspect ratio of 5.3 ± 0.6, a diameter on the order of 70 nm, and wall thicknesses on the order of 15 nm. The PDA nanotubes exhibited photothermal conversion upon irradiation at near infrared wavelengths; a temperature increase of 30 °C was observed when a 250 μg ml−1 sample was subjected to 1 W cm−2 density irradiation at 808 nm wavelength. Analysis indicated that the prepared tubes had slightly higher photothermal conversion efficiency than PDA nanospheres. An antitumor drug, doxorubicin, was used as a model to test the potential for drug delivery of the organic nanotubes. The nanotubes exhibited higher loading capacities than PDA nanospheres and were capable of controlled release at pHs relevant to human serum and tumors (pH 7.4 and 5.0 respectively). Drug release rates varied as a function of system pH and application of near infrared irradiation. Release of doxorubicin was enhanced at a pH of 5.0, and retarded at a pH of 7.4. Irradiation with 808 nm wavelength light also increased the release of doxorubicin.


16 July 2012 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
NFNathan J. Fanter
Nathan J. Fanter
AUAuburn University
Auburn University
CBChamp L. Baker
Champ L. Baker
Background: In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Hypothesis: Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Study Design: Controlled laboratory study. Methods: The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Results: Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. Conclusion: In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Clinical Relevance: Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.