Over the past decade, the number of positron emission tomography/computed tomography (PET/CT) imaging procedures has increased substantially. This imaging technique provides accurate functional and anatomical information, particularly for oncological applications. Separately, both PET and CT are considered as high-dose imaging modalities. With the increased use of PET/CT, one could expect an increase in radiation doses to staff and patients. As such, major efforts have been made to reduce radiation dose in PET/CT facilities. Variations in working techniques have made it difficult to compare published results. This study aimed to review the literature on proposed methods to reduce patient and staff dose in clinical PET/CT imaging. A brief overview of some published information on staff and patient doses will be analysed and presented. Recent trends regarding radiation protection in PET/CT imaging will be discussed, and practical recommendations for reducing radiation doses to staff and patients will be discussed and summarised. Generally, the CT dose component is often higher in magnitude than the dose from PET alone; as such, focusing on CT dose reduction will decrease the overall patient dose in PET/CT imaging studies. The following factors should be considered in order to reduce the patient's dose from CT alone: proper justification for ordering contrast-enhanced CT; use of automatic exposure control features; use of adaptive statistical iterative reconstruction algorithms; and optimisation of scan parameters, especially scan length. The PET dose component can be reduced by administration of lower activity to the patient, optimisation of the workflow, and appropriate use of protective devices and engineered systems. At the international level, there is wide variation in work practices among institutions. The current observed trends are such that the annual dose limits for radiation workers in PET/CT imaging are unlikely to be exceeded.
Aim: The aim of this study was to evaluate awareness and knowledge about radiation risks and safety principles among medical students at the College of Medicine, University of Hail, Hail, Saudi Arabia, in their clinical years. Materials and Methods: In this cross-sectional study, an anonymous electronic questionnaire was sent to 174 randomly selected students in clinical years 4–6. The questionnaire contained 38 questions. The respondents’ answers to these questions were used to classify them according to their demographic characteristics and to evaluate their knowledge about common imaging modalities, radiation risks, and safety measures. The data were analyzed using the Statistical Package for the Social Sciences (SPSS) software, version 22. Results: Seventy-five (51.7%) of 145 respondents were female and 70 (48.3%) were male. Fifty-five respondents (37.9%) were in year 4, 38 (26.2%) were in year 5, and 52 (35.9%) were in year 6. The mean score for knowledge about common imaging modalities was 4.10 ± 2.030 of 10, that for knowledge about the risks of radiation was 3.17 ± 1.954 (range, 0–8) of 13, and that for knowledge about radiation protection measures was low at 0.79 ± 0.922 (range, 0–4) of 8. Overall, there was an improvement in knowledge about the imaging modalities and the risks of radiation as the number of clinical years increased (P = 0.000), but it was still unsatisfactory. Conclusion: The results of this study indicate that the medical students at the University of Hail have very limited knowledge about radiation risks and safety measures. These findings highlight the need for urgent action to improve students’ knowledge of these topics.
30 June 1999 in Journal of Food Composition and Analysis
The aim of this study was to test the feasibility of using Gafchromic XR-QA2 films in the measurements of patient entrance surface dose (ESD) during the micturating cystourethrogram (MCUG) examination in paediatric patients. Radiochromic films were used to map the entrance dose and to identify the location of peak surface dose (PSD). Direct in vivo measurements of entrance dose were conducted by placing a radiochromic film between the patient and the examination table. The measured ESD values for the commonly performed MCUG fluoroscopic examinations at the authors' institution was in the range of 1.2–7.8 mGy and the PSD in the range of 1.2–8.5 mGy per MCUG procedure for patients with age ranging from 1 to 12 y old. Gafchromic films (XR-QA2) were found to be an efficient and practical dosimetry method that can be easily used to measure clinical patient entrance doses during fluoroscopically guided procedures and potentially in other diagnostic investigations.
7 June 2019 in Reports of Practical Oncology and Radiotherapy
Aim: Blood irradiators (BI) initial acceptance testing and routine annual dosimetry checks require radiation dose measurements in order to comply with regulatory requirements. Background: Traditionally thermo-luminescence dosimeters (TLD) have been used to measure the dose. The EBT3 film is reported to be a better dosimeter for low energy X-rays than its predecessors EBT2 and EBT. To the best of our knowledge, the use of EBT3 films to perform dosimetry on X-ray based BI has not been reported yet. Materials and methods We performed routine radiation dosimetry checks using EBT3 films on a new X-ray based BI and compared the results with TLD dosimetry. Calibration films were irradiated with radiation beam from a Co-60 Gamma Knife (GK) radiosurgery machine and, alternatively, using an Ir-192 high dose rate (HDR) brachytherapy device. The films were calibrated to cover a wide dose range from 1 to 40 Gy. Such a wide dose range has not been reported yet in BI film dosimetry. Results: We obtained a relative difference of about 6.6% between doses measured using TLD and those measured using EBT3 films. Both irradiation methods using GK or HDR were found to be adequate for the calibration of the EBT3 Gafchromic films. Conclusions: We recommend the use of EBT3 films in routine X-ray based BI dosimetry checks. The presented method takes advantage of available radiotherapy equipment that can be efficiently used for EBT3 films calibration. The method is fast, reproducible and saves valuable medical physicist's time.