The ability to manipulate therapeutic agents in fluids is of interest to improve the efficiency of targeted drug delivery. Ultrasonic manipulation has great potential in the field of therapeutic applications as it can trap and manipulate micro-scale objects. Recently, several methods of ultrasonic manipulation have been studied through standing wave, traveling wave, and acoustic streaming. Among them, the traveling wave based ultrasonic manipulation is showing more advantage for in vivo environments. In this paper, we present a novel ultrasonic transducer (UT) array with a hemispherical arrangement that generates active traveling waves with phase modulation to manipulate a micromotor in water. The feasibility of the method could be demonstrated by in vitro and ex vivo experiments conducted using a UT array with 16 transducers operating at 1 MHz. The phase of each transducer was controlled independently for generating a twin trap and manipulation of a micromotor in 3D space. This study shows that the ultrasonic manipulation device using active traveling waves is a versatile tool that can be used for precise manipulation of a micromotor inserted in a human body and targeted for drug delivery.
Targeted drug delivery using microrobots manipulated by an external actuator has significant potential to be a practical approach for wireless delivery of therapeutic agents to the targeted tumor. This work aimed to develop a novel acoustic manipulation system and macrophage-based microrobots (Macbots) for a study in targeted tumor therapy. The Macbots containing superparamagnetic iron oxide nanoparticles (SPIONs) can serve as drug carriers. Under an acoustic field, a microrobot cluster of the Macbots is manipulated by following a predefined trajectory and can reach the target with a different contact angle. As a fundamental validation, we investigated an in vitro experiment for targeted tumor therapy. The microrobot cluster could be manipulated to any point in the 4 × 4 × 4 mm region of interest with a position error of less than 300 μm. Furthermore, the microrobot could rotate in the O-XY plane with an angle step of 45 degrees without limitation of total angle. Finally, we verified that the Macbots could penetrate a 3D tumor spheroid that mimics an in vivo solid tumor. The outcome of this study suggests that the Macbots manipulated by acoustic actuators have potential applications for targeted tumor therapy.
Acoustic tweezers provide unique capabilities in medical applications, such as contactless manipulation of small objects (e.g., cells, compounds or living things), from nanometer-sized extracellular vesicles to centimeter-scale structures. Additionally, they are capable of being transmitted through the skin to trap and manipulate drug carriers in various media. However, these capabilities are hindered by the limitation of controllable degrees of freedom (DoFs) or are limited maneuverability. In this study, we explore the potential application of acoustical tweezers by presenting a five-DoF contactless manipulation acoustic system (AcoMan). The system has 30 ultrasound transducers (UTs) with single-side arrangement that generates active traveling waves to control the position and orientation of a fully untethered nanocarrier clusters (NCs) in a spherical workspace in water capable of three DoFs translation and two DoFs rotation. In this method, we use a phase modulation algorithm to independently control the phase signal for 30 UTs and manipulate the NCs’ positions. Phase modulation and switching power supply for each UT are employed to rotate the NCs in the horizontal plane and control the amplitude of power supply to each UT to rotate the NCs in the vertical plane. The feasibility of the method is demonstrated by in vitro and ex vivo experiments using porcine ribs. A significant portion of this study could advance the therapeutic application such a system as targeted drug delivery.
Microrobots driven by multiple external power sources have emerged as promising tools for targeted drug and stem cell delivery in tissue regeneration. However, navigating and imaging these devices within a complex colloidal vascular system at a clinical scale is challenging. Ultrasonic actuators have gained interest in the field of non-contact manipulation of micromachines due to their label-free biocompatible nature and safe operation history. This research presents experimentally validated simulation results of ultrasonic actuation using a novel ultrasonic transducer array with a hemispherical arrangement that generates active traveling waves with phase modulation. Blood flow is used as a carrier force while the direction and path are controlled by blocking undesirable paths using a highly focused acoustic field. In the experiments, the microrobot cluster was able to follow a predefined trajectory and reach the target. The microrobot size, maximum radiation pressure, and focus position were optimized for certain blood flow conditions. The outcomes suggest that this acoustic manipulation module has potential applications in targeted tumor therapy.
The ultrasonic actuator can be used in medical applications because it is label-free, biocompatible, and has a demonstrated history of safe operation. Therefore, there is an increasing interest in using an ultrasonic actuator in the non-contact manipulation of micromachines in various materials and sizes for therapeutic applications. This research aims to design, fabricate, and characterize a single-sided transducer array with 56 channels operating at 500 kHz, which provide benefits in the penetration of tissue. The fabricated transducer is calibrated using a phase reference calibration method to reduce position misalignment and phase discrepancies caused by acoustic interaction. The acoustic fields generated by the transducer array are measured in a 300 mm × 300 mm × 300 mm container filled with de-ionized water. A hydrophone is used to measure the far field in each transducer array element, and the 3D holographic pattern is analyzed based on the scanned acoustic pressure fields. Next, the phase reference calibration is applied to each transducer in the ultrasonic actuator. As a result, the homogeneity of the acoustic pressure fields surrounding the foci area is improved, and the maximum pressure is also increased in the twin trap. Finally, we demonstrate the capability to trap and manipulate micromachines with acoustic power by generating a twin trap using both optical camera and ultrasound imaging systems in a water medium. This work not only provides a comprehensive study on acoustic actuators but also inspires the next generation to use acoustics in medical applications.
20 January 2026 in Journal of Micromechanics and Microengineering
This study presents the development and validation of compact acoustic lens–based actuators for precise, contactless manipulation of 3D-printed microparticles in water. Two types of passive polydimethylsiloxane acoustic lenses, namely twin-trap and vortex-trap configurations, were designed using spatial phase modulation principles and fabricated through mold casting with 3D-printed molds. Finite element simulations confirmed that the lenses generated structured acoustic pressure fields suitable for 3D microparticle trapping, including dual-lobe pressure distributions for twin-trap lenses and rotationally symmetric fields for vortex-trap lenses. Hydrophone measurements experimentally verified the simulated pressure profiles and demonstrated strong agreement in focal location and acoustic field structure. An 800 µm-diameter 3D-printed microparticle fabricated from VeroWhitePlus RGD835 was used to experimentally validate trapping and manipulation performance. A comprehensive evaluation was performed for four distinct lens–transducer actuator configurations, including both single-element and array-based transducer implementations for each lens type. Stable trapping was achieved at focal distances of 3, 5, 38, and 50 mm above the lens surface, corresponding to the respective actuator designs. The actuators were subsequently translated along predefined 3D trajectories measuring 3 mm × 3 mm for single-element lenses and 10 mm × 10 mm for array-based lenses in the OXZ and OYZ planes, respectively. Accurate trajectory tracking was demonstrated, with positional errors smaller than the microparticle diameter for all configurations. These results demonstrate that the proposed acoustic lens–based actuators enable real-time, non-contact 3D manipulation of solid microparticles with high precision and stability. The passive lens architecture, compact form factor, and ability to generate structured acoustic fields indicate strong potential for applications in mesoscale object handling, biological assay platforms, and microrobotic control in open aqueous environments.