Jana Windhaber

Jana Windhaber


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HVHenri Vähä-Ypyä
Henri Vähä-Ypyä
JBJakob Bretterhofer
Jakob Bretterhofer
PHPauliina Husu
Pauliina Husu
JWJana Windhaber
Jana Windhaber
Tommi VasankariTommi Vasankari
Tommi Vasankari
HSHarri Sievänen
Harri Sievänen
Accelerometer data can be used to estimate incident oxygen consumption (VO2) during physical activity. Relationships between the accelerometer metrics and VO2 are typically determined using specific walking or running protocols on a track or treadmill. In this study, we compared the predictive performance of three different metrics based on the mean amplitude deviation (MAD) of the raw three-dimensional acceleration signal during maximal tests performed on a track or treadmill. A total of 53 healthy adult volunteers participated in the study, 29 performed the track test and 24 the treadmill test. During the tests, the data were collected using hip-worn triaxial accelerometers and metabolic gas analyzers. Data from both tests were pooled for primary statistical analysis. For typical walking speeds at VO2 less than 25 mL/kg/min, accelerometer metrics accounted for 71–86% of the variation in VO2. For typical running speeds starting from VO2 of 25 mL/kg/min up to over 60 mL/kg/min, 32–69% of the variation in VO2 could be explained, while the test type had an independent effect on the results, except for the conventional MAD metrics. The MAD metric is the best predictor of VO2 during walking, but the poorest during running. Depending on the intensity of locomotion, the choice of proper accelerometer metrics and test type may affect the validity of the prediction of incident VO2.

6 June 2020 in Journal Of Hypertension
Verified
Journal Article
Closed access
FSFalko Skrabal
Falko Skrabal
TWThomas Weber
Thomas Weber
KSKatharina Skrabal
Katharina Skrabal
JWJana Windhaber
Jana Windhaber
HEHasibullah Ehsas
Hasibullah Ehsas
JBJohannes Boyer
Johannes Boyer
Objective: Measurements of pulse wave velocity are generally thought to be too impractical for clinical routine. This study aimed to develop a method that can be performed during routine 12-channel ECG. Methods: A 12-channel ECG simultaneously supplies arterial impedance plethysmographic signals from the extremities beside segmental multifrequency impedance measurements for obtaining body composition. The origin of the plethysmographic signal (volume wave) at the arms and legs was determined at the level of the elbows and the knees. The volume wave velocity (VWV) at the aorta and femoral arteries was calculated from the time difference of the plethysmographic signals between arms and legs. Results: Automated measurement of VWV was highly reproducible (r = 0.96). In 107 participants in perfect health, VWV in different models was positively related to age, physiological hemoglobin A 1C, triglycerides, normal standardized unattended blood pressure, but not to physiological low-density lipoprotein-cholesterol and high-density lipoprotein-cholesterol. Aortofemoral VWV was significantly higher in patients with established coronary artery disease than in healthy controls of the same age group (18.1 ± 5.8 vs. 11.9 ± 1.7 m/s, P < 0.001). VWV in study participants was higher than tonometrically determined pulse wave velocity as muscular arteries are included (13.2 ± 5.81 vs. 8.8 ± 2.98 m/s, n = 115, P < 0.001). Conclusion: These background arterial impedance plethysmographic measurements for the measurement of VWV made simultaneously during 12-channel ECG show promise for large-scale, routine clinical assessment of large artery function.

7 March 2014 in Monatsschrift Kinderheilkunde
Verified
Journal Article
Closed access
PDF file
JWJana Windhaber
Jana Windhaber
PSP.H. Schober
P.H. Schober

26 January 2021 in Molecules
Verified
Journal Article
Open access
PDF file
GWGert Warncke
Gert Warncke
Georg SingerGeorg Singer
Georg Singer
JWJana Windhaber
Jana Windhaber
LSLukas Schabl
Lukas Schabl
EFElena Friehs
Elena Friehs
CCChristoph Castellani
Christoph Castellani
The aim of this study was to analyze the exhaled volatile organic compounds (VOCs) profile, airway microbiome, lung function and exercise performance in congenital diaphragmatic hernia (CDH) patients compared to healthy age and sex-matched controls. A total of nine patients (median age 9 years, range 6–13 years) treated for CDH were included. Exhaled VOCs were measured by GC–MS. Airway microbiome was determined from deep induced sputum by 16S rRNA gene sequencing. Patients underwent conventional spirometry and exhausting bicycle spiroergometry. The exhaled VOC profile showed significantly higher levels of cyclohexane and significantly lower levels of acetone and 2-methylbutane in CDH patients. Microbiome analysis revealed no significant differences for alpha-diversity, beta-diversity and LefSe analysis. CDH patients had significantly lower relative abundances of Pasteurellales and Pasteurellaceae. CDH patients exhibited a significantly reduced Tiffeneau Index. Spiroergometry showed no significant differences. This is the first study to report the VOCs profile and airway microbiome in patients with CDH. Elevations of cyclohexane observed in the CDH group have also been reported in cases of lung cancer and pneumonia. CDH patients had no signs of impaired physical performance capacity, fueling controversial reports in the literature.

12 March 2021 in European Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
JWJana Windhaber
Jana Windhaber
MSMonica Steinbauer
Monica Steinbauer
MHMagdalena Holter
Magdalena Holter
AWAnnemarie Wieland
Annemarie Wieland
KKKristina Kogler
Kristina Kogler
HTHolger Till
Holger Till
Purpose: To compare performance data of adolescents collected with five different bicycle spiroergometry protocols and to assess the necessity for establishing standard values for each protocol. Methods: One-hundred-twenty adolescents completed two bicycle spiroergometries within 14 days. One of the two tests was performed based on our institutional weight-adapted protocol (P0). The other test was performed based on one out of four exercise protocols widely used for children and adolescents (P1, 2, 3 or 4) with 30 persons each. The two tests were performed in a random order. Routine parameters of cardiopulmonary exercise tests (CPET) such as VO2peak, maximum power, O2 pulse, OUES, VE/VCO2 slope as well as ventilatory and lactate thresholds were investigated. Agreement between protocols was evaluated by Bland–Altman analysis, coefficients of variation (CV) and intra-class correlation coefficients (ICC). Results: None of the CPET parameters were significantly different between P0 and P1, 2, 3 or 4. For most of the parameters, low biases between P0 and P1–P4 were found and 95% confidence intervalls were narrow. CV and ICC values largely corresponded to well-defined analytical goals (CV < 10% and ICC > 0.9). Only maximal power (Pmax) showed differences in size and drift of the bias depending on the length of the step duration of the protocols. Conclusion: Comparability between examination protocols has been shown for CPET parameters independent on step duration. Protocol-dependent standard values do not appear to be necessary. Only Pmax is dependent on the step duration, but in most cases, this has no significant influence on the fitness assessment.

30 June 2007 in Atherosclerosis Supplements
Verified
Journal Article
Closed access
HMH. Mangge
H. Mangge
KSK. Sargsyan
K. Sargsyan
GAG. Almer
G. Almer
ANA. Nemet
A. Nemet
WSW. Spindelboeck
W. Spindelboeck
MTM. Truschnig-Wilders
M. Truschnig-Wilders