Mohamed Murshid Shamsuddeen

Mr. Mohamed Murshid Shamsuddeen

Korea Institute of Industrial Technology
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Renewable Energy
Verified
Journal Article
Closed access
Mohamed Murshid ShamsuddeenMohamed Murshid Shamsuddeen
Mohamed Murshid Shamsuddeen
JPJungwan Park
Jungwan Park
YCYoung-Seok Choi
Young-Seok Choi
Jin-Hyuk KimJin-Hyuk Kim
Jin-Hyuk Kim

1 March 2023 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
MSMohammad Abu Shahzer
Mohammad Abu Shahzer
YCYong Cho
Yong Cho
Mohamed Murshid ShamsuddeenMohamed Murshid Shamsuddeen
Mohamed Murshid Shamsuddeen
Jin-Hyuk KimJin-Hyuk Kim
Jin-Hyuk Kim
Cavitating vortex rope at part load (PL) condition at lower values of the Thoma number (σ) induces severe pressure fluctuation and efficiency reduction in a Francis turbine, which ultimately hinders continuous energy production. Installation of fins at draft tube (DT) can mitigate these instabilities and can safeguard the turbine operation with lower maintenance costs. The effect of fins on hydraulic performance and internal flow physics at PL condition with the variation of σ is examined in the present numerical investigation. For the two extreme opposite values of σ, the flow characteristics are predicted accurately for the turbine with and without fins by conducting transient simulations using ANSYS-CFX. The numerical findings on the structured and unstructured grid points are validated with the experimental results. The turbine's performance remains constant for higher values of Thoma numbers, and as the value decreases, the performance declines. The cavitation vortex rope formation inside the DT with fins is mitigated significantly at the minimum σ, while at the maximum value, the vortex rope with bubble generation is restricted. Compared to the without fin case, the swirl intensity is minimized remarkably (68%) with the presence of fins at the lowest σ. The maximum cavitation rate is manifested by the DT without fins, which is about 60% higher than the DT with fins. At minimum σ, extreme pressure pulsations are induced inside the DT without fins, which are reduced by 43% in the finned draft tube. Therefore, stable energy production is maximized with the installation of fins at both Thoma numbers.

1 April 2023 in Energy
Verified
Journal Article
Open access
Mohamed Murshid ShamsuddeenMohamed Murshid Shamsuddeen
Mohamed Murshid Shamsuddeen
SMSang-Bum Ma
Sang-Bum Ma
NPNo-Hyun Park
No-Hyun Park
KKKyung Min Kim
Kyung Min Kim
Jin-Hyuk KimJin-Hyuk Kim
Jin-Hyuk Kim

16 October 2020 in Journal of Thermal Science
Verified
Journal Article
Closed access
PDF file
Mohamed Murshid ShamsuddeenMohamed Murshid Shamsuddeen
Mohamed Murshid Shamsuddeen
DCDong-An Cha
Dong-An Cha
SKSeon-Chang Kim
Seon-Chang Kim
TKToshiaki Kanemoto
Toshiaki Kanemoto
Jin-Hyuk KimJin-Hyuk Kim
Jin-Hyuk Kim

1 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Mohamed Murshid ShamsuddeenMohamed Murshid Shamsuddeen
Mohamed Murshid Shamsuddeen
SMSang-Bum Ma
Sang-Bum Ma
SKSung Kim
Sung Kim
JYJi-Hoon Yoon
Ji-Hoon Yoon
KLKwang-Hee Lee
Kwang-Hee Lee
Jin-Hyuk KimJin-Hyuk Kim
Jin-Hyuk Kim
A multistage centrifugal pump is designed for pumping low-viscosity, highly volatile and flammable chemicals, including hydrocarbons, for high head requirements. The five-stage centrifugal pump consists of a double-suction impeller at the first stage followed by a twin volute. The impellers for stages two through five are single-suction impellers followed by diffuser vanes and return channel vanes. The analytical performance is calculated initially in the design stage by applying similarity laws to an existing scaled-down pump model designed for low flow rate applications. The proposed pump design is investigated using computational fluid dynamics tools to study its performance in design and off-design conditions for water as the base fluid. The design feasibility of the centrifugal pump is tested for other fluids, such as water at a high temperature and pressure, diesel and debutanized diesel. The pump design is found to be suitable for a variety of fluids and operating ranges. The losses in the pump are analyzed in each stage at the best efficiency point. The losses in efficiency and head are observed to be higher in the second stage than in other stages. The detailed flow behavior at the second stage is studied to identify the root cause of the losses. Design modifications are recommended to diminish the losses and improve the overall performance of the pump.

23 July 2024 in Heliyon
Verified
Journal Article
Open access
Mohamed Murshid ShamsuddeenMohamed Murshid Shamsuddeen
Mohamed Murshid Shamsuddeen
MSMohammad Abu Shahzer
Mohammad Abu Shahzer
MRMin-Su Roh
Min-Su Roh
Jin-Hyuk KimJin-Hyuk Kim
Jin-Hyuk Kim
Ultra-low-head turbines can harness energy from previously deemed unsuitable sites, including natural and man-made locations like shallow estuaries, marine canals, and industrial waterways. Various hydro-turbine concepts were evaluated for their potential to extract power from these areas. These turbines can generate renewable energy for utilization in remotely located areas. A horizontal-axis screw turbine concept, horizontal and vertical Savonius turbine concepts, axial turbine concepts, and a gate turbine concept were investigated in the present study using computational fluid dynamic tools. Reynolds Averaged Navier Stokes equations with a shear stress transport model are used to calculate the flow field. The numerical methodology is then verified with previously published data. The turbine performances were compared and the design feasibility was analyzed to find the most effective turbine design which can extract the maximum energy. The gate turbine concept exhibited a significant power output with high efficiency while the screw turbine showed the lowest performance among the tested designs. The horizontal Savonius turbine displayed enhanced performance with an increment of 23.25 % compared to the screw turbine. An additional parametric study is conducted on the gate turbine namely, the number of runner blades, and the gate installation angle. The 3-bladed gate turbine installed at a 14° gate angle showed superior power output and efficiency than other hydrokinetic turbines.