Shinji Yoshii

Dr. Shinji Yoshii

Kyushu Dental University, Fukuoka, Japan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2019 in Materials
Verified
Journal Article
Open access
PDF file
AWAyako Washio
Ayako Washio
TMTakahiko Morotomi
Takahiko Morotomi
SYShinji Yoshii
Shinji Yoshii
CKChiaki Kitamura
Chiaki Kitamura
Endodontic treatment for a tooth with damaged dental pulp aims to both prevent and cure apical periodontitis. If the tooth is re-infected as a result of a poorly obturated root canal, periapical periodontitis may set-in due to invading bacteria. To both avoid any re-infection and improve the success rate of endodontic retreatment, a treated root canal should be three-dimensionally obturated with a biocompatible filling material. Recently, bioactive glass, one of the bioceramics, is focused on the research area of biocompatible biomaterials for endodontics. Root canal sealers derived from bioactive glass-based have been developed and applied in clinical endodontic treatments. However, at present, there is little evidence about the patient outcomes, sealing mechanism, sealing ability, and removability of the sealers. Herein, we have developed a bioactive glass-based root canal sealer and provided evidence concerning its physicochemical properties, biocompatibility, sealing ability, and removability. We also review the classification of bioceramics and characteristics of bioactive glass. Additionally, we describe the application of bioactive glass to facilitate the development of a new root canal sealer. Furthermore, this review shows the potential application of bioactive glass-based cement as a root canal filling material in the absence of semisolid core material.

29 February 2024 in Polymers
Verified
Journal Article
Open access
PDF file
SISoshi Ikemoto
Soshi Ikemoto
YKYuya Komagata
Yuya Komagata
SYShinji Yoshii
Shinji Yoshii
CMChihiro Masaki
Chihiro Masaki
RHRyuji Hosokawa
Ryuji Hosokawa
HIHiroshi Ikeda
Hiroshi Ikeda
The objective of this study is to evaluate the impact of the thickness and translucency of various computer-aided design/computer-aided manufacturing (CAD/CAM) materials on the polymerization of dual-cure resin cement in endocrown restorations. Three commercially available CAD/CAM materials—lithium disilicate glass (e.max CAD), resin composite (CERASMART), and a polymer-infiltrated ceramic network (ENAMIC)—were cut into plates with five different thicknesses (1.5, 3.5, 5.5, 7.5, and 9.5 mm) in both high-translucency (HT) and low-translucency (LT) grades. Panavia V5, a commercial dual-cure resin cement, was polymerized through each plate by light irradiation. Post-polymerization treatment was performed by aging at 37 °C for 24 h under light-shielding conditions. The degree of conversion and Vickers hardness measurements were used to characterize the polymerization of the cement. The findings revealed a significant decrease in both the degree of conversion and Vickers hardness with increasing thickness across all CAD/CAM materials. Notably, while the differences in the degree of conversion and Vickers hardness between the HT and LT grades of each material were significant immediately after photoirradiation, these differences became smaller after post-polymerization treatment. Significant differences were observed between samples with a 1.5 mm thickness (conventional crowns) and those with a 5.5 mm or greater thickness (endocrowns), even after post-polymerization treatment. These results suggest that dual-cure resin cement in endocrown restorations undergoes insufficient polymerization.

AWAyako Washio
Ayako Washio
HMHiroki Miura
Hiroki Miura
TMTakahiko Morotomi
Takahiko Morotomi
MIMiki Ichimaru-Suematsu
Miki Ichimaru-Suematsu
HMHirotake Miyahara
Hirotake Miyahara
CKChiaki Kitamura
Chiaki Kitamura
The purpose of this study is to evaluate the effect of a bioactive glass-based root canal sealer, Nishika Canal Sealer BG (CS-BG), on the incidence of postoperative pain (PP) after root canal obturation (RCO). Eleven dentists performed pulpectomy or infected root canal treatments for 555 teeth. During RCO, CS-BG was used. After RCO, the rate of PP and the factors affecting PP (pain during RCO and pain immediately after RCO) were analyzed. PP was observed in eight teeth (1.5%), and within 7 days after RCO, there were no teeth with pain. In these teeth with PP, there was a significant difference in the occurrence of pain during RCO, but not in the occurrence of pain immediately after RCO, when compared with pulpectomy and infected root canal treatment. These clinical results show that CS-BG has an excellent biocompatibility, and can suppress the distress of patients during RCO.

20 August 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MFMasataka Fujimoto
Masataka Fujimoto
MOMasahiro Okuda
Masahiro Okuda
SYShinji Yoshii
Shinji Yoshii
SISatoshi Ikezawa
Satoshi Ikezawa
TUToshitsugu Ueda
Toshitsugu Ueda
CKChiaki Kitamura
Chiaki Kitamura
Objective: In dentistry, dentists perform many treatments with a few visually magnified information. About deep area of root canals, it commonly relies on exploration carried out with the fingers of the dentist, because the root canal entrance is very small to be observed. In clinical practice, the intraoral camera and endoscopic systems are separate devices, and there are no sensors to capture both pictures of the whole tooth and those inside the root canal. Objective of this research is to combine the intraoral camera and endoscopic system facilitating to use clinical practice. Methods: We propose an endoscopic system based on the thin image fiber, SOPROLIFE intraoral camera as an image sensor, and a new adaptor to connect the two parts. We observed resolution charts with 50, 25, 10, and 5 line pairs (LP)/mm patterns. The acquired images are processed to both remove fixed-pattern noise using robust principal component analysis and enhance contrast. Results: The acquired images containing all LP/mm patterns were clear and showed higher contrast after processing. Visibility of the processed images is 1.7, 1.6, 2.2, and 1.9 times higher than that of the raw images for 50, 25, 10, and 5 LP/mm patterns, respectively. Conclusion: Our fabricated endoscopic system based on the SOPROLIFE intraoral camera could observe 50, 25, 10, and 5 LP/mm patterns. After image processing, the noise was reduced, and high contrast images were obtained. Significance: This system can be considered as a further step towards facilitating non-invasive and contactless systems in clinical practice.

Verified
Journal Article
Open access
PDF file
RYRieko Yamanaka
Rieko Yamanaka
MUMichihiko Usui
Michihiko Usui
KKKaoru Kobayashi
Kaoru Kobayashi
SOSatoru Onizuka
Satoru Onizuka
SKShingo Kasai
Shingo Kasai
TNTatsuji Nishihara
Tatsuji Nishihara
Porphyromonas gingivalis is the most pathogenic periodontal bacterium in the world. Recently, P. gingivalis has been considered responsible for dysbiosis during the development of periodontitis. This study aimed to evaluate a novel immunochromatographic device using monoclonal antibodies against P. gingivalis in subgingival plaques. A total of 72 patients with chronic periodontitis and 53 periodontally healthy volunteers underwent clinical and microbiological examinations. Subgingival plaque samples were analyzed for the presence of P. gingivalis and compared using real-time polymerase chain reaction (PCR). In the periodontitis group, a significant positive correlation was observed between the test device scores and the real-time PCR results. The specificity, positive predictive value, negative predictive value, and accuracy of the test device for P. gingivalis, as determined by real-time PCR, were 98%, 94%, 89%, and 90%, respectively. There were significant differences in bacterial counts by real-time PCR among the groups with different ranges of device scores. Additionally, there was a significant positive correlation between the device scores for P. gingivalis and periodontal parameters. These results suggest that this novel immunochromatographic device can be effectively used for rapid detection and semi-quantification of P. gingivalis in subgingival plaques.

1 January 2013 in International Journal on Smart Sensing and Intelligent Systems
Verified
Journal Article
Open access
SYShinji Yoshii
Shinji Yoshii
YZYupeng Zhang
Yupeng Zhang
SISatoshi Ikezawa
Satoshi Ikezawa
CKChiaki Kitamura
Chiaki Kitamura
TNTatsuji Nishihara
Tatsuji Nishihara
TUToshitsugu Ueda
Toshitsugu Ueda
Observation of the oral cavity microstructure is an important factor for a successful dental treatment. None of the many currently available diagnostic equipment can accurately observe the microstructure. In this study, we have designed an endoscope with a single graded-index multimode fiber of 600-μm diameter that can reach the narrow spaces in the oral cavity and can perform both image acquisition and sample illumination using a prism beam splitter, unlike the conventional endoscope using separate fibers. Thus, the side branch of the teeth and the subgingival calculus can be accurately observed with a resolution of up to 10 μm.