Masataka Fujimoto

Dr. Masataka Fujimoto


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
AWAyako Washio
Ayako Washio
HMHiroki Miura
Hiroki Miura
TMTakahiko Morotomi
Takahiko Morotomi
MIMiki Ichimaru-Suematsu
Miki Ichimaru-Suematsu
HMHirotake Miyahara
Hirotake Miyahara
CKChiaki Kitamura
Chiaki Kitamura
The purpose of this study is to evaluate the effect of a bioactive glass-based root canal sealer, Nishika Canal Sealer BG (CS-BG), on the incidence of postoperative pain (PP) after root canal obturation (RCO). Eleven dentists performed pulpectomy or infected root canal treatments for 555 teeth. During RCO, CS-BG was used. After RCO, the rate of PP and the factors affecting PP (pain during RCO and pain immediately after RCO) were analyzed. PP was observed in eight teeth (1.5%), and within 7 days after RCO, there were no teeth with pain. In these teeth with PP, there was a significant difference in the occurrence of pain during RCO, but not in the occurrence of pain immediately after RCO, when compared with pulpectomy and infected root canal treatment. These clinical results show that CS-BG has an excellent biocompatibility, and can suppress the distress of patients during RCO.

20 August 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MFMasataka Fujimoto
Masataka Fujimoto
MOMasahiro Okuda
Masahiro Okuda
SYShinji Yoshii
Shinji Yoshii
SISatoshi Ikezawa
Satoshi Ikezawa
TUToshitsugu Ueda
Toshitsugu Ueda
CKChiaki Kitamura
Chiaki Kitamura
Objective: In dentistry, dentists perform many treatments with a few visually magnified information. About deep area of root canals, it commonly relies on exploration carried out with the fingers of the dentist, because the root canal entrance is very small to be observed. In clinical practice, the intraoral camera and endoscopic systems are separate devices, and there are no sensors to capture both pictures of the whole tooth and those inside the root canal. Objective of this research is to combine the intraoral camera and endoscopic system facilitating to use clinical practice. Methods: We propose an endoscopic system based on the thin image fiber, SOPROLIFE intraoral camera as an image sensor, and a new adaptor to connect the two parts. We observed resolution charts with 50, 25, 10, and 5 line pairs (LP)/mm patterns. The acquired images are processed to both remove fixed-pattern noise using robust principal component analysis and enhance contrast. Results: The acquired images containing all LP/mm patterns were clear and showed higher contrast after processing. Visibility of the processed images is 1.7, 1.6, 2.2, and 1.9 times higher than that of the raw images for 50, 25, 10, and 5 LP/mm patterns, respectively. Conclusion: Our fabricated endoscopic system based on the SOPROLIFE intraoral camera could observe 50, 25, 10, and 5 LP/mm patterns. After image processing, the noise was reduced, and high contrast images were obtained. Significance: This system can be considered as a further step towards facilitating non-invasive and contactless systems in clinical practice.

19 February 2021 in Materials
Verified
Journal Article
Open access
PDF file
HMHiroki Miura
Hiroki Miura
SYShinji Yoshii
Shinji Yoshii
MFMasataka Fujimoto
Masataka Fujimoto
AWAyako Washio
Ayako Washio
TMTakahiko Morotomi
Takahiko Morotomi
CKChiaki Kitamura
Chiaki Kitamura
This study aimed to examine the resin polymerization of a fiber post/core resin construction system and the interface between resin and root canal sealers, which are important for root canal sealing. We used the i-TFC Luminus fiber post and i-TFC Luminus LC flow (i-TFC-L), the GC fiber post and Unifil Core EM (GCF), and the FiberKor post and Build-It FR (FKP) as core construction systems, and Nishika Canal Sealer BG (CS-BG), Metaseal Soft (META), and Nishika Canal Sealer EN (CS-EN) as sealers. The light transmission of fiber posts (n = 5), the polymerization of core resin (n = 5), and the adhesion between the sealer and core resin (n = 10) were evaluated. The i-TFC Luminus fiber post light transmission was significantly higher than that of other posts. Without shielding, i-TFC-L showed a significantly greater amount of polymerized resin than the other systems. With shielding, although i-TFC-L showed a significantly greater amount of polymerized resin immediately after light irradiation, polymerized resin was significantly greater in GCF and FKP after 10 min. All systems adhered to CS-BG and META but not to CS-EN. These results indicate that resin polymerization in the cavity differs among fiber post/core resin construction systems and that the adhesion of the resin and sealer depends on the property of the sealer.

28 October 2016
Verified
Book Chapter
Closed access
PDF file
MFMasataka Fujimoto
Masataka Fujimoto
SYShinji Yoshii
Shinji Yoshii
SISatoshi Ikezawa
Satoshi Ikezawa
TUToshitsugu Ueda
Toshitsugu Ueda
CKChiaki Kitamura
Chiaki Kitamura