Young Geun Song

Dr. Young Geun Song


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2020 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
JPJung Joon Pyeon
Jung Joon Pyeon
IBIn-Hwan Baek
In-Hwan Baek
YSYoung Geun Song
Young Geun Song
GKGwang Su Kim
Gwang Su Kim
ACAh-Jin Cho
Ah-Jin Cho
SKSeong Keun Kim
Seong Keun Kim
Flexible sensor with ALD-synthesized SnS2 flakes achieve extremely high response to NO2 at room temperature.

7 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
KLKwangjae Lee
Kwangjae Lee
YSYoung-Seok Shim
Young-Seok Shim
YSYoung Geun Song
Young Geun Song
SHSoodeok Han
Soodeok Han
YLYoun-Sung Lee
Youn-Sung Lee
CKChong-Yun Kang
Chong-Yun Kang
A fire detector is the most important component in a fire alarm system. Herein, we present the feasibility of a highly sensitive and rapid response gas sensor based on metal oxides as a high performance fire detector. The glancing angle deposition (GLAD) technique is used to make the highly porous structure such as nanocolumns (NCs) of various metal oxides for enhancing the gas-sensing performance. To measure the fire detection, the interface circuitry for our sensors (NiO, SnO2, WO3 and In2O3 NCs) is designed. When all the sensors with various metal-oxide NCs are exposed to fire environment, they entirely react with the target gases emitted from Poly(vinyl chlorides) (PVC) decomposed at high temperature. Before the emission of smoke from the PVC (a hot-plate temperature of 200 °C), the resistances of the metal-oxide NCs are abruptly changed and SnO2 NCs show the highest response of 2.1. However, a commercial smoke detector did not inform any warning. Interestingly, although the NiO NCs are a p-type semiconductor, they show the highest response of 577.1 after the emission of smoke from the PVC (a hot-plate temperature of 350 °C). The response time of SnO2 NCs is much faster than that of a commercial smoke detector at the hot-plate temperature of 350 °C. In addition, we investigated the selectivity of our sensors by analyzing the responses of all sensors. Our results show the high potential of a gas sensor based on metal-oxide NCs for early fire detection.

28 April 2023 in Nanoscale Advances
Verified
Journal Article
Open access
PDF file
JLJinho Lee
Jinho Lee
MPMinsu Park
Minsu Park
YSYoung Geun Song
Young Geun Song
DCDonghwi Cho
Donghwi Cho
KLKwangjae Lee
Kwangjae Lee
Seokwoo JeonSeokwoo Jeon
Seokwoo Jeon
The decoration of graphene quantum dots enhances the NO2 gas sensing performance of SnO2 nanodomes by utilizing both electrical and chemical sensitization effects, leading to an impressive reduction in the theoretical detection limit.

24 January 2022 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
YSYoung Geun Song
Young Geun Song
IBIn-Hwan Baek
In-Hwan Baek
JYJae-Gyun Yim
Jae-Gyun Yim
TETaeyong Eom
Taeyong Eom
TCTaek-Mo Chung
Taek-Mo Chung
SKSeong Keun Kim
Seong Keun Kim
A highly sensitive NO 2 gas sensor of p-type SnS operating at room temperature is developed using crosslinked SnS nanoplates self-formed only on SiO 2 nanorods, without an additional patterning process.

9 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
GKGwang Su Kim
Gwang Su Kim
YPYumin Park
Yumin Park
JSJoonchul Shin
Joonchul Shin
YSYoung Geun Song
Young Geun Song
CKChong-Yun Kang
Chong-Yun Kang
The breath gas analysis through gas phase chemical analysis draws attention in terms of non-invasive and real time monitoring. The array-type sensors are one of the diagnostic methods with high sensitivity and selectivity towards the target gases. Herein, we presented a 2 × 4 sensor array with a micro-heater and ceramic chip. The device is designed in a small size for portability, including the internal eight-channel sensor array. In2O3 NRs and WO3 NRs manufactured through the E-beam evaporator’s glancing angle method were used as sensing materials. Pt, Pd, and Au metal catalysts were decorated for each channel to enhance functionality. The sensor array was measured for the exhaled gas biomarkers CH3COCH3, NO2, and H2S to confirm the respiratory diagnostic performance. Through this operation, the theoretical detection limit was calculated as 1.48 ppb for CH3COCH3, 1.9 ppt for NO2, and 2.47 ppb for H2S. This excellent detection performance indicates that our sensor array detected the CH3COCH3, NO2, and H2S as biomarkers, applying to the breath gas analysis. Our results showed the high potential of the gas sensor array as a non-invasive diagnostic tool that enables real-time monitoring.

1 November 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JSJoonchul Shin
Joonchul Shin
YSYoung Geun Song
Young Geun Song
SJSung-Jin Jung
Sung-Jin Jung
TYTaeehee Yoon
Taeehee Yoon
GKGwang Su Kim
Gwang Su Kim
JKJin-Sang Kim
Jin-Sang Kim